Javascript must be enabled to continue!
Analysis of the instrumentation time and cleaning between manual and rotary techniques in deciduous molars
View through CrossRef
The rotary instrumentation provides shorter instrumentation time with greater comfort for the patient but few studies have been conducted on primary teeth. Objective: this study compared the cleaning ability and instrumentation time between manual and rotary techniques in deciduous molars. Material and methods: a total of 15 molars were selected, submitted to coronal opening and root canal filled with India ink. After 48 hours, the teeth were divided into three groups: G1 – manual instrumentation with K files, G2 – rotary system Endowave, and G3 – rotary system ProTaper. After instrumentation, the teeth were sectioned and three blinded examiners evaluated the root canal cleaning. The mode of scores of examiners was analyzed by the Kruskal-Wallis test. The instrumentation time was recorded and the results were statistically analyzed by ANOVA. Results: the ProTaper system presented shorter instrumentation time compared to manual instrumentation (p = 0.0339). Endowave system did not present statistically significant difference in the instrumentation time compared to the other groups. There were no significant differences between groups concerning the ability of root canal cleaning (p = 0.6188). Conclusion: ProTaper system revealed shorter treatment time and similar cleaning ability compared to the other techniques, thus being indicated for deciduous teeth.
Fundacao Educacional da Regiao de Joinville - Univille
Title: Analysis of the instrumentation time and cleaning between manual and rotary techniques in deciduous molars
Description:
The rotary instrumentation provides shorter instrumentation time with greater comfort for the patient but few studies have been conducted on primary teeth.
Objective: this study compared the cleaning ability and instrumentation time between manual and rotary techniques in deciduous molars.
Material and methods: a total of 15 molars were selected, submitted to coronal opening and root canal filled with India ink.
After 48 hours, the teeth were divided into three groups: G1 – manual instrumentation with K files, G2 – rotary system Endowave, and G3 – rotary system ProTaper.
After instrumentation, the teeth were sectioned and three blinded examiners evaluated the root canal cleaning.
The mode of scores of examiners was analyzed by the Kruskal-Wallis test.
The instrumentation time was recorded and the results were statistically analyzed by ANOVA.
Results: the ProTaper system presented shorter instrumentation time compared to manual instrumentation (p = 0.
0339).
Endowave system did not present statistically significant difference in the instrumentation time compared to the other groups.
There were no significant differences between groups concerning the ability of root canal cleaning (p = 0.
6188).
Conclusion: ProTaper system revealed shorter treatment time and similar cleaning ability compared to the other techniques, thus being indicated for deciduous teeth.
Related Results
Morphology Analysis of Human Fourth Molars Using Computed Microtomography - Pilot Study
Morphology Analysis of Human Fourth Molars Using Computed Microtomography - Pilot Study
Analyze the morphological characteristics of fourth molars from non-syndromic patients using computed microtomography (microCT). Five human fourth molars (case group) and other thr...
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Abstract
Aiming at the problems of fast wear and short service life of rotary tillage blade in gneiss mountainous area, and the lack of accurate and reliable discrete eleme...
Studi Rendemen Finir dan Besarnya Limbah Pada Pengupasan Finir dengan Mesin Rotary Lathe Tipe Spindleless
Studi Rendemen Finir dan Besarnya Limbah Pada Pengupasan Finir dengan Mesin Rotary Lathe Tipe Spindleless
In general, the log-block peeling yield on a rotary lathe machine ranges from 70 - 80% of the log volume in the form of veneer, and the remaining 20-30% is waste. This variation de...
Root Development of Permanent Incisors and Mandibular Molars in Correlation with Treatment Plan
Root Development of Permanent Incisors and Mandibular Molars in Correlation with Treatment Plan
Abstract
Background: The incisors and molars play a major role in the formation and function of permanent dentition. Much research has been devoted to investigating the eruption of...
A Dynamic Analysis of the Rotary Cutting System of King Grass Shredder
A Dynamic Analysis of the Rotary Cutting System of King Grass Shredder
With the rotary cutting system of king grass shredder as the research object, this paper established finite element models for rotating shaft, rotating shaft-belt pulley, rotating ...
MODAL ANALISIS PADA ROTARY KILN DENGAN MENGGUNAKAN METODE ELEMEN HINGGA
MODAL ANALISIS PADA ROTARY KILN DENGAN MENGGUNAKAN METODE ELEMEN HINGGA
This research is based on the general damage to the rotary kiln due to continuous use. Then the results from the burned in a Rotary Kiln So we need a prevention to overcome it. Tes...
Comparative analysis of four cleaning methods of endodontic files
Comparative analysis of four cleaning methods of endodontic files
Due to the size and design of endodontic files, these instruments have been considered one of the most difficult to clean among all dental instruments. The debris maintenance withi...
Pediatric Rotary Files: Evolution to Revolution
Pediatric Rotary Files: Evolution to Revolution
The main goal of pulp therapy in primary dentition is to preserve the primary tooth thus protecting future normal occlusion. Routinely, pulp debridement and canal shaping ar...