Javascript must be enabled to continue!
Bubble Effects on the Acoustic Doppler Velocimeter (ADV) Measurements
View through CrossRef
Acoustic Doppler Velocimeter (ADV) is a useful technique for measuring flow velocities with frequency variations of up to approximately 200 Hz in laboratory settings and in field applications. Although measuring velocity with ADV has advantages over other velocity measurement methods, this technique is sensitive to operating conditions: in addition to noise, the signal can contain spikes with large amplitudes, a disadvantage of ADV. In this study, the effect of bubbles on ADV signals is experimentally assessed in a laboratory setting. Bubbles can intersect the sampling volume and the acoustic beams creating spikes. The impact and amplitude of these spikes is a function of the bubble size and position when it crosses the ADV sampling volume and the acoustic beams. Bubbles that intersect the sampling volume generate spikes in all three velocity directions simultaneously; bubbles that intersect acoustic beams, which span between the sampling volume and the ADV receivers, impact the velocity data in one or two directions, and has a negligible effect in the third direction. Bubbles that intersect the X-direction acoustic beam create spikes in velocity data in both X- and Z-directions, but have no significant impact on the Y-direction; the Y- and X-directions have spikes and the Z-direction is not significantly impacted, when bubbles intersect the Y-direction acoustic beam. In addition, spikes increase the magnitude of the power spectra at high frequencies. Without bubbles, the autocorrelation in the time domain decreases in value as the time-lag increases, approaching zero after 5 seconds. The presences of bubbles cause a large peak in the autocorrelation at a zero time-lag, and no autocorrelation thereafter. Furthermore, the autocorrelation without bubbles permit turbulence length scales to be calculated because of the positive autocorrelation value; unless spikes are removed by using an appropriate filter when bubbles are present, turbulence length scales cannot be calculated because the autocorrelation is zero.
Title: Bubble Effects on the Acoustic Doppler Velocimeter (ADV) Measurements
Description:
Acoustic Doppler Velocimeter (ADV) is a useful technique for measuring flow velocities with frequency variations of up to approximately 200 Hz in laboratory settings and in field applications.
Although measuring velocity with ADV has advantages over other velocity measurement methods, this technique is sensitive to operating conditions: in addition to noise, the signal can contain spikes with large amplitudes, a disadvantage of ADV.
In this study, the effect of bubbles on ADV signals is experimentally assessed in a laboratory setting.
Bubbles can intersect the sampling volume and the acoustic beams creating spikes.
The impact and amplitude of these spikes is a function of the bubble size and position when it crosses the ADV sampling volume and the acoustic beams.
Bubbles that intersect the sampling volume generate spikes in all three velocity directions simultaneously; bubbles that intersect acoustic beams, which span between the sampling volume and the ADV receivers, impact the velocity data in one or two directions, and has a negligible effect in the third direction.
Bubbles that intersect the X-direction acoustic beam create spikes in velocity data in both X- and Z-directions, but have no significant impact on the Y-direction; the Y- and X-directions have spikes and the Z-direction is not significantly impacted, when bubbles intersect the Y-direction acoustic beam.
In addition, spikes increase the magnitude of the power spectra at high frequencies.
Without bubbles, the autocorrelation in the time domain decreases in value as the time-lag increases, approaching zero after 5 seconds.
The presences of bubbles cause a large peak in the autocorrelation at a zero time-lag, and no autocorrelation thereafter.
Furthermore, the autocorrelation without bubbles permit turbulence length scales to be calculated because of the positive autocorrelation value; unless spikes are removed by using an appropriate filter when bubbles are present, turbulence length scales cannot be calculated because the autocorrelation is zero.
Related Results
Vapor Bubble Interaction With a Superheated Wall
Vapor Bubble Interaction With a Superheated Wall
Sliding bubbles are known to augment heat transfer rates on the surface on which they slide. The pre-cursor problem — the bubble approaching an inclined superheated wall provides t...
Two parvoviruses that cause different diseases in mink have different transcription patterns: transcription analysis of mink enteritis virus and Aleutian mink disease parvovirus in the same cell line
Two parvoviruses that cause different diseases in mink have different transcription patterns: transcription analysis of mink enteritis virus and Aleutian mink disease parvovirus in the same cell line
The two parvoviruses of mink cause very different diseases. Mink enteritis virus (MEV) is associated with rapid, high-level viral replication and acute disease. In contrast, infect...
Numerical investigation of central breakup of large bubble induced by liquid jet
Numerical investigation of central breakup of large bubble induced by liquid jet
A large spherical bubble rising in quiescent liquid generally leads to the formation of a toroidal bubble (central breakup). In this paper, we investigate the bubble dynamics durin...
Simulation of dynamic process of double bubble coupled acoustic cavitation
Simulation of dynamic process of double bubble coupled acoustic cavitation
In order to simulate the acoustic cavitation process of double-bubble coupling, based on the fluid dynamics governing equation and fluid volume fraction model, this paper proposes ...
Five years of treatment with adefovir dipivoxil in Chinese patients with HBeAg‐positive chronic hepatitis B
Five years of treatment with adefovir dipivoxil in Chinese patients with HBeAg‐positive chronic hepatitis B
AbstractBackgroundAdefovir dipivoxil (ADV) is a nucleotide analogue with proven efficacy in chronic hepatitis B (CHB).AimsThis study investigated long‐term ADV treatment in HBeAg‐p...
Oxygen transfer from bubble-plumes
Oxygen transfer from bubble-plumes
Air-bubble plumes produced beneath ocean breaking waves have important roles in gas transfer between atmosphere and ocean because the gas within the bubbles, convected by breaking-...
PD characteristics and deterioration mechanism of oil-impregnated pressboard with bubble defect
PD characteristics and deterioration mechanism of oil-impregnated pressboard with bubble defect
The bubbles are typical defects of oil-paper insulation systems, and
partial discharge (PD) initiated by them can significantly degrade the
insulating performance of oil-paper insu...
Effect of film viscoelasticity on the finite deformation of a spherical bubble
Effect of film viscoelasticity on the finite deformation of a spherical bubble
According to the strain energy density function for finite deformation of viscoelastic material, the relaxation function of the Maxwell mode, and the deformation gradient tensor of...

