Microfluidic devices generally consume microliter to submicroliter volumes of sample and are thus well suited for use when the required reagents are scarce or expensive. Because microfluidic devices operate in a regime in which small Reynolds numbers govern the delivery of fluid samples, reagent mixing and subsequent reactivity has been a severe limiting factor in their applicability. The inclusion of packed beads in the microfluidic device repertoire has several advantages: molecular assemblies for the assay are created outside the channel on beads and characterized with flow cytometry, uniform populations of beads may be assured through rapid cytometric sorting, beads present a larger surface area for the display of receptors than flat surfaces, rapid mixing in the microcolumn is achieved because the distance that must be covered by diffusion is limited to the (≤1-μm) interstitial space between the closely packed receptorbearing beads, and analytes are captured in a flow-through format and, as such, each bead can act as a local concentrator of analytes. Progress in the combined use of beads and microfluidic devices has been limited by the ability to pack beads at specific sections of microfluidic devices. A subsequent challenge associated with the packed microcolumns of beads is the substantial pressure drop that affects the fluid flow velocity. However, some of these challenges have been overcome in the design of simple model systems that have potential applications in DNA analysis, chromatography, and immunoassays. It is the intent of this chapter to examine the recent emergence of small-volume heterogeneous immunoassays, using beads trapped in microchannels, while excluding other closely related applications such as capillary electrophoresis and flow injection–based approaches. Of necessity, the authors’ interests and availability of information pertinent to the specific discussions presented below impose additional restrictions. To date, there are only a handful of applications that combine packed beads and microfluidic devices, and even fewer that make the overt connection between flow cytometry–based assays and beads. Harrison and coworkers have provided one of the earliest conceptual demonstrations of the capability to incorporate packed beads in microfluidic devices for analytical purposes.
Title: Flow Cytometry, Beads, and Microchannels
Description:
Microfluidic devices generally consume microliter to submicroliter volumes of sample and are thus well suited for use when the required reagents are scarce or expensive.
Because microfluidic devices operate in a regime in which small Reynolds numbers govern the delivery of fluid samples, reagent mixing and subsequent reactivity has been a severe limiting factor in their applicability.
The inclusion of packed beads in the microfluidic device repertoire has several advantages: molecular assemblies for the assay are created outside the channel on beads and characterized with flow cytometry, uniform populations of beads may be assured through rapid cytometric sorting, beads present a larger surface area for the display of receptors than flat surfaces, rapid mixing in the microcolumn is achieved because the distance that must be covered by diffusion is limited to the (≤1-μm) interstitial space between the closely packed receptorbearing beads, and analytes are captured in a flow-through format and, as such, each bead can act as a local concentrator of analytes.
Progress in the combined use of beads and microfluidic devices has been limited by the ability to pack beads at specific sections of microfluidic devices.
A subsequent challenge associated with the packed microcolumns of beads is the substantial pressure drop that affects the fluid flow velocity.
However, some of these challenges have been overcome in the design of simple model systems that have potential applications in DNA analysis, chromatography, and immunoassays.
It is the intent of this chapter to examine the recent emergence of small-volume heterogeneous immunoassays, using beads trapped in microchannels, while excluding other closely related applications such as capillary electrophoresis and flow injection–based approaches.
Of necessity, the authors’ interests and availability of information pertinent to the specific discussions presented below impose additional restrictions.
To date, there are only a handful of applications that combine packed beads and microfluidic devices, and even fewer that make the overt connection between flow cytometry–based assays and beads.
Harrison and coworkers have provided one of the earliest conceptual demonstrations of the capability to incorporate packed beads in microfluidic devices for analytical purposes.
Related Results
Procedure for Latex beads coating with glycolipids v1
Procedure for Latex beads coating with glycolipids v1
Goal: This document aims to standardize the protocol for latex beads coating with the Mycobacterium leprae phenolic glycolipid “PGL I”. Beads-PGL I coating is used, for example, fo...
Procedures for assaying the association of bacteria or fluorescent latex beads to cells by flow cytometry v1
Procedures for assaying the association of bacteria or fluorescent latex beads to cells by flow cytometry v1
Goal: This document aims to standardize the protocol for assaying the association of bacteria or fluorescent latex beads in eukaryotic cells by flow cytometry. General considerat...
Effect of Surface Roughness on Gaseous Flow Through Microchannels
Effect of Surface Roughness on Gaseous Flow Through Microchannels
Abstract
This paper presents an experimental investigation on nitrogen and helium flow through microchannels etched in silicon with hydraulic diameters between 10 an...
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Abstract
The orifice discharge coefficient (CD) is the constant required to correct theoretical flow rate to actual flow rate. It is known that single phase orifi...
Pressure Analysis of DST Flow Period Or Slug Flow For Horizontal Wells In Homogeneous Reservoir
Pressure Analysis of DST Flow Period Or Slug Flow For Horizontal Wells In Homogeneous Reservoir
Abstract
By the transient pressure for horizontal well with constant flow rate and Duhamel's principle, this paper presents the method to calculate the transient ...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
AbstractIntroductionIn patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protective of future ischemic cerebral events. Reserve cerebral ...
Chitosan/tripolyphosphate nanoparticles in active and passive microchannels
Chitosan/tripolyphosphate nanoparticles in active and passive microchannels
Background and purpose:
In recent years, the interest in chitosan nanoparticles has increased due to their application, especially in drug delivery. The main aim of thi...
Validation of the volumetric flow cytometry for bovine sperm concentration
Validation of the volumetric flow cytometry for bovine sperm concentration
AbstractSperm concentration is a stronghold of the andrological evaluation and the production of insemination doses. The use of haemocytometers, although considered the gold standa...