Dosimetric verification of radiotherapy treatment planning system at TMSS Cancer Center, Bogura, Bangladesh
View through CrossRef
Authentication of TPS is the component of the QA program for RTPS and planning process. So, verification of dose calculation algorithm is essential to measure the efficiency of the dose calculations. The goal is to assess how far the dosage measured deviates from the dose predicted by the treatment planning system (TPS) algorithm using a CIRS Thorax phantom. It has been done to measure the dosimetric variations of 6MV, 10MV and 15MV photon beams. The phantom was initially scanned using a CT-simulator, and the raw data from the gated scans were then exported to TPS to perform the planning. Using this planning, the phantom was irradiated for four different cases. The computed dose was then compared with the measured dose to ensure TPS validity. The findings demonstrate that the variation between the measured doses in altered holes of the CIRS thorax phantom and the calculated doses by TPS was within the allowed limit except few points of four cases. Max. and Min. deviations for 6MV were 3.87% and 0.05% respectively. On the other hand, Max. and Min. deviations for 10MV were 7.87% and 0.12% respectively and that for 15MV are 4.44% and 0.02% respectively. Satisfactory results were obtained for lung and bone substitute. The results demonstrate the accuracy of the doses determined by the treatment planning system algorithm using a thorax phantom, and they also demonstrate the competency of using the phantom for regular verification. In case of external beam radiation therapy with AAA algorithm, the CIRS Thorax Phantom is suitable for dose computation in heterogeneous medium. However it is more compatible for 6MV than 10MV and 15MV.
Title: Dosimetric verification of radiotherapy treatment planning system at TMSS Cancer Center, Bogura, Bangladesh
Description:
Authentication of TPS is the component of the QA program for RTPS and planning process.
So, verification of dose calculation algorithm is essential to measure the efficiency of the dose calculations.
The goal is to assess how far the dosage measured deviates from the dose predicted by the treatment planning system (TPS) algorithm using a CIRS Thorax phantom.
It has been done to measure the dosimetric variations of 6MV, 10MV and 15MV photon beams.
The phantom was initially scanned using a CT-simulator, and the raw data from the gated scans were then exported to TPS to perform the planning.
Using this planning, the phantom was irradiated for four different cases.
The computed dose was then compared with the measured dose to ensure TPS validity.
The findings demonstrate that the variation between the measured doses in altered holes of the CIRS thorax phantom and the calculated doses by TPS was within the allowed limit except few points of four cases.
Max.
and Min.
deviations for 6MV were 3.
87% and 0.
05% respectively.
On the other hand, Max.
and Min.
deviations for 10MV were 7.
87% and 0.
12% respectively and that for 15MV are 4.
44% and 0.
02% respectively.
Satisfactory results were obtained for lung and bone substitute.
The results demonstrate the accuracy of the doses determined by the treatment planning system algorithm using a thorax phantom, and they also demonstrate the competency of using the phantom for regular verification.
In case of external beam radiation therapy with AAA algorithm, the CIRS Thorax Phantom is suitable for dose computation in heterogeneous medium.
However it is more compatible for 6MV than 10MV and 15MV.
Related Results
Termite Mound Soils for Sustainable Production of Bricks
Termite Mound Soils for Sustainable Production of Bricks
Abstract
The article presents the alternative use of termite mound soils (TMSs) as full replacement for clay soils in brick production. TMSs from two localities, Jaw...
Edoxaban and Cancer-Associated Venous Thromboembolism: A Meta-analysis of Clinical Trials
Edoxaban and Cancer-Associated Venous Thromboembolism: A Meta-analysis of Clinical Trials
Abstract
Introduction
Cancer patients face a venous thromboembolism (VTE) risk that is up to 50 times higher compared to individuals without cancer. In 2010, direct oral anticoagul...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Comprehensive update on cancer scenario of Bangladesh
Comprehensive update on cancer scenario of Bangladesh
AbstractBangladesh, at 142 million people, is the ninth most populous country in the world. There are 13 to 15 lakh cancer patients in Bangladesh, with about two lakh patients newl...
Current Developments in Radiotherapy Quality Control Methods
Current Developments in Radiotherapy Quality Control Methods
Quality control is of critical importance to ensure the accurate and reliable implementation of treatment in radiotherapy. Radiotherapy is a primary method of treating diseases suc...
Radiotherapy refusal in breast cancer with breast-conserving surgery
Radiotherapy refusal in breast cancer with breast-conserving surgery
Abstract
Background
Although radiotherapy after breast-conserving surgery has been the standard treatment for breast cancer, some people still refus...
Structural performance of fish market in Bogura district, Bangladesh
Structural performance of fish market in Bogura district, Bangladesh
One of the most important blossom trades in the economy of Bangladesh is fish marketing. To understand the current practices of fish market and marketing systems in Bogura district...
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Abstract
A cervical rib (CR), also known as a supernumerary or extra rib, is an additional rib that forms above the first rib, resulting from the overgrowth of the transverse proce...