Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Real Time Voltage Stability Estimation under Contingencies by Generalized Curve Fit Method using PMU

View through CrossRef
An accurate voltage stability monitoring scheme is necessary to take possible remedial action. Recent developments in Phasor Measurement Units (PMUs) technology provide the foundation for online voltage stability monitoring of a power system network.  In this paper, the generalized curve fit method using PMUs in the system has been used to access voltage stability of the system and a sensitivity based approach has been used to identify critical buses of the system. Voltage stability margin has been obtained and compared using generalized curve fit method and continuation power flow method using PMUs in the system. Variations in voltage stability margin caused by changing load patterns have also been considered while estimating voltage stability under contingencies.  Nose curves obtained using generalized curve fit and continuation power flow methods are also compared. Case studies have been performed on a standard IEEE 14-bus system and practical 246-bus Northern Regional Power Grid (NRPG) system representing power network of nine states of India, with the help of Real Time Digital Simulation (RTDS) and Power System Analysis Toolbox (PSAT) software.
Title: Real Time Voltage Stability Estimation under Contingencies by Generalized Curve Fit Method using PMU
Description:
An accurate voltage stability monitoring scheme is necessary to take possible remedial action.
Recent developments in Phasor Measurement Units (PMUs) technology provide the foundation for online voltage stability monitoring of a power system network.
 In this paper, the generalized curve fit method using PMUs in the system has been used to access voltage stability of the system and a sensitivity based approach has been used to identify critical buses of the system.
Voltage stability margin has been obtained and compared using generalized curve fit method and continuation power flow method using PMUs in the system.
Variations in voltage stability margin caused by changing load patterns have also been considered while estimating voltage stability under contingencies.
 Nose curves obtained using generalized curve fit and continuation power flow methods are also compared.
Case studies have been performed on a standard IEEE 14-bus system and practical 246-bus Northern Regional Power Grid (NRPG) system representing power network of nine states of India, with the help of Real Time Digital Simulation (RTDS) and Power System Analysis Toolbox (PSAT) software.

Related Results

Optimal Configuration of PMU in Power System
Optimal Configuration of PMU in Power System
In order to use the least number of phasor measurement unit (PMU) to guarantee the power system completely observable, an optimal PMU configuration method in power system was put f...
Design of Ultra-Low Power and Area Circuits for Cell-Size Microsystems
Design of Ultra-Low Power and Area Circuits for Cell-Size Microsystems
The concept of smart dust emerged in the early 21st century to enable large-scale distributed sensing and computation. Progress was hindered for years due to the slow development o...
Research Trends and Applications of PMUs
Research Trends and Applications of PMUs
This work is a survey of current trends in applications of PMUs. PMUs have the potential to solve major problems in the areas of power system estimation, protection, and stability....
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...
Curve Shape Modification and Fairness Evaluation
Curve Shape Modification and Fairness Evaluation
A method to generate a quintic NURBS curve which passes through the given points is described. In this case, there are four more equations than there are positions of the control p...
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
A Method of Introducing PMU Current Measurement to Nonlinear State Estimation
A Method of Introducing PMU Current Measurement to Nonlinear State Estimation
Aiming at the problem that the current measurements provided by phasor measurement unit (PMU) is difficult to introduce to traditional state estimation, a new method to solve the c...
ECONOMIC ESSENCE OF THE FINANCIAL STABILITY OF THE BANKING SYSTEM
ECONOMIC ESSENCE OF THE FINANCIAL STABILITY OF THE BANKING SYSTEM
Introduction. The article examines the essence of financial stability and stability of the banking system in order to analyze and understand them. The main approaches to interpreti...

Back to Top