Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

High-resolution analysis of von Willebrand factor multimeric composition defines a new variant of type I von Willebrand disease with aberrant structure but presence of all size multimers (type IC)

View through CrossRef
Abstract In Type I von Willebrand disease, the whole series of von Willebrand factor (vWF) multimers is present in plasma, but all are decreased in quantity. No structural abnormality of individual multimers has been demonstrated so far in these patients. We now describe five individuals, from two unrelated families, who had this form of the disease and in whom the complex banding pattern of each vWF multimer was markedly abnormal. Inheritance was autosomal dominant and the clinical expression was mild. A bleeding history was elicited in three of the patients and included recurrent epistaxis, menometrorrhagia, and bleeding following tooth extraction. Replacement therapy had never been required. Although vWF levels in plasma were within the normal range in all of them, the ristocetin cofactor activity was decreased in four, and the bleeding time was prolonged in three. Analysis of vWF multimeric structure by agarose gel electrophoresis, including a newly developed high-resolution technique, demonstrated that the main band of each multimer was present, but a second, well-defined band always seen in normal individuals was missing in the patients. Two additional bands had altered mobility and were less well defined than in normal subjects, and a fifth, less intense band was also undetectable in the patients. Treatment with 1-deamino-8-D-arginine vasopressin (DDAVP) was assessed in two patients. It caused the circulating levels of vWF to increase and correct the bleeding time, but did not alter the structural abnormality. This study describes, therefore, a new variant form of Type I von Willebrand disease with aberrant structure of individual repeating multimers and an associated functional abnormality of vWF. In keeping with previously accepted terminology, the designation of Type IC von Willebrand disease has been adopted for this new variant.
Title: High-resolution analysis of von Willebrand factor multimeric composition defines a new variant of type I von Willebrand disease with aberrant structure but presence of all size multimers (type IC)
Description:
Abstract In Type I von Willebrand disease, the whole series of von Willebrand factor (vWF) multimers is present in plasma, but all are decreased in quantity.
No structural abnormality of individual multimers has been demonstrated so far in these patients.
We now describe five individuals, from two unrelated families, who had this form of the disease and in whom the complex banding pattern of each vWF multimer was markedly abnormal.
Inheritance was autosomal dominant and the clinical expression was mild.
A bleeding history was elicited in three of the patients and included recurrent epistaxis, menometrorrhagia, and bleeding following tooth extraction.
Replacement therapy had never been required.
Although vWF levels in plasma were within the normal range in all of them, the ristocetin cofactor activity was decreased in four, and the bleeding time was prolonged in three.
Analysis of vWF multimeric structure by agarose gel electrophoresis, including a newly developed high-resolution technique, demonstrated that the main band of each multimer was present, but a second, well-defined band always seen in normal individuals was missing in the patients.
Two additional bands had altered mobility and were less well defined than in normal subjects, and a fifth, less intense band was also undetectable in the patients.
Treatment with 1-deamino-8-D-arginine vasopressin (DDAVP) was assessed in two patients.
It caused the circulating levels of vWF to increase and correct the bleeding time, but did not alter the structural abnormality.
This study describes, therefore, a new variant form of Type I von Willebrand disease with aberrant structure of individual repeating multimers and an associated functional abnormality of vWF.
In keeping with previously accepted terminology, the designation of Type IC von Willebrand disease has been adopted for this new variant.

Related Results

On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
The complex multimeric composition of factor VIII/von Willebrand factor
The complex multimeric composition of factor VIII/von Willebrand factor
We have analyzed the multimeric structure of factor VIII/von Willebrand factor in plasma by sodium dodecyl sulfate electrophoresis using gels of varying porosity and a discontinuou...
The complex multimeric composition of factor VIII/von Willebrand factor
The complex multimeric composition of factor VIII/von Willebrand factor
Abstract We have analyzed the multimeric structure of factor VIII/von Willebrand factor in plasma by sodium dodecyl sulfate electrophoresis using gels of varying por...
von Willebrand disease "Vicenza" with larger-than-normal (supranormal) von Willebrand factor multimers
von Willebrand disease "Vicenza" with larger-than-normal (supranormal) von Willebrand factor multimers
Abstract When normal volunteers or patients with type I von Willebrand disease (VWD) are given desmopressin (DDAVP), a set of larger-than-normal (supranormal) von Wi...
Selective absence of large forms of factor VIII/von Willebrand factor in acquired von Willebrand's syndrome. Response to transfusion
Selective absence of large forms of factor VIII/von Willebrand factor in acquired von Willebrand's syndrome. Response to transfusion
A previously healthy elderly man with mucocutaneous bleeding was found to have a benign monoclonal IgG gammapathy associated with criteria for severe von Willebrand disease (Factor...

Back to Top