Corrosion potential: influence of moisture, water-cement ratio, chloride content and concrete cover

View through CrossRef
ABSTRACT The method of measuring the corrosion potential is used as an electrochemical tool for helping the monitoring of the corrosion of reinforcements of concrete structures. As a criterion for evaluating results it is common to use intervals of corrosion potential and their correlation with corrosion probability, as precognizes ASTM C 876:2015. With this criterion, it is possible to establish an overview of the thermodynamic situation of corrosion in the structure or in the test specimen in laboratory. However, the method is influenced by several factors related with the concrete, the environment and with procedures adopted at the moment of executing the readings. Aiming to provide information to guide the technical and scientific environment regarding the right use of this type of non-destructive testing, the objective of this work is to evaluate some possible factors influencing the reading of corrosion potential, such as: moisture content of the concrete, water/cement ratio, thickness of the concrete cover and degree of contamination by chlorides. Results indicate that moisture and degree of contamination of the concrete by chloride ions had a tendency of making the corrosion potential more electronegative. Besides, it was verified that the influence of the cover is different for the case of contaminated concrete (1% of chlorides by mass of cement) and not contaminated with chlorides: the influence of the thickness of the cover, in the case of concrete contaminated by chlorides, was inversely proportional, in other words, the greater the cover thickness is, the less electronegative the value of the corrosion potential will be. On the other hand, in cases of concretes without chlorides, the effect of the cover thickness in the readings or corrosion potential was irrelevant. All this information was proved with 95% of statistical significance.
Title: Corrosion potential: influence of moisture, water-cement ratio, chloride content and concrete cover
Description:
ABSTRACT The method of measuring the corrosion potential is used as an electrochemical tool for helping the monitoring of the corrosion of reinforcements of concrete structures.
As a criterion for evaluating results it is common to use intervals of corrosion potential and their correlation with corrosion probability, as precognizes ASTM C 876:2015.
With this criterion, it is possible to establish an overview of the thermodynamic situation of corrosion in the structure or in the test specimen in laboratory.
However, the method is influenced by several factors related with the concrete, the environment and with procedures adopted at the moment of executing the readings.
Aiming to provide information to guide the technical and scientific environment regarding the right use of this type of non-destructive testing, the objective of this work is to evaluate some possible factors influencing the reading of corrosion potential, such as: moisture content of the concrete, water/cement ratio, thickness of the concrete cover and degree of contamination by chlorides.
Results indicate that moisture and degree of contamination of the concrete by chloride ions had a tendency of making the corrosion potential more electronegative.
Besides, it was verified that the influence of the cover is different for the case of contaminated concrete (1% of chlorides by mass of cement) and not contaminated with chlorides: the influence of the thickness of the cover, in the case of concrete contaminated by chlorides, was inversely proportional, in other words, the greater the cover thickness is, the less electronegative the value of the corrosion potential will be.
On the other hand, in cases of concretes without chlorides, the effect of the cover thickness in the readings or corrosion potential was irrelevant.
All this information was proved with 95% of statistical significance.

Related Results

The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
This study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contaminat...
FLY ASH FOUNDATION REINFORCED BY CEMENT–SOIL MIXING PILES
FLY ASH FOUNDATION REINFORCED BY CEMENT–SOIL MIXING PILES
Cement-soil mixing piles have been commonly used to enhance the bearing capacity of fly ash stratum and mitigate the settlement damage to the surrounding environment. However, only...
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
ABSTRACT: The integrity of cement sheath is critical to oil and gas effective extraction, in which the cement displacement efficiency and solidify quality are the...
Compressive Strength of Concrete with Nano Cement
Compressive Strength of Concrete with Nano Cement
Nano technology plays a very vital role in all the areas of research. The incorporation of nano materials in concrete offers many advantages and improves the workability, the stren...
New Horizons of Well Bonding: Cement Expansion in Absence of Water Access
New Horizons of Well Bonding: Cement Expansion in Absence of Water Access
Abstract Zonal isolation for primary cementing is generally of concern when there is potential for gas migration. The challenge for the industry is to achieve a long...
Experimental and Numerical Determination of Cement Casing Microannulus
Experimental and Numerical Determination of Cement Casing Microannulus
ABSTRACT The key to successful long term well integrity of cement-casing is to understand and investigate the hydraulic sealing of cementing annulus by detecting ...
Cement Evaluation - A Risky Business
Cement Evaluation - A Risky Business
Abstract Cement evaluation is commonly thought of as running a cement bond log (CBL) and attempting to interpret the results to determine if there is isolation in th...
Experiment Study of Stress and Pore Pressure in Setting Cement Paste
Experiment Study of Stress and Pore Pressure in Setting Cement Paste
ABSTRACT: Cement sheath integrity plays an important role in ensuring the wellbore safety. Shear failure, tensile crack or debonding may happen in the cement shea...

Back to Top