Javascript must be enabled to continue!
Comparative Study of Different Ion-exchange Membrane Types in Diffusion Dialysis for the Separation of Sulfuric Acid and Nickel Sulfate
View through CrossRef
The application of diffusion dialysis using various types of ion-exchange membranes for the separation of sulfuric acid and nickel sulfate has been evaluated. The process of dialysis separation of a real waste solution from an electroplating facility containing 252.3 g/L of sulfuric acid, 20.9 g/L of nickel ions and small amounts of zinc, iron, copper ions, etc. has been studied. Heterogeneous cation-exchange membrane containing sulfo groups and heterogeneous anion-exchange membranes with different thicknesses (from 145 μm to 550 μm) and types of fixed groups (4 samples with quaternary amino groups and 1 sample with secondary and tertiary amino groups) are used. The diffusion fluxes of sulfuric acid, nickel sulfate, and the total and osmotic fluxes of the solvent are determined. The use of a cation-exchange membrane does not allow separation of the components, since the fluxes of both components are low and comparable in magnitude. The use of anion-exchange membranes makes it possible to efficiently separate sulfuric acid and nickel sulfate. At the same time, the thin dialysis membrane turns out to be the most effective, as well as the membranes with quaternary amino groups, and the membrane with secondary and tertiary amino groups proved to be the least effective.
Title: Comparative Study of Different Ion-exchange Membrane Types in Diffusion Dialysis for the Separation of Sulfuric Acid and Nickel Sulfate
Description:
The application of diffusion dialysis using various types of ion-exchange membranes for the separation of sulfuric acid and nickel sulfate has been evaluated.
The process of dialysis separation of a real waste solution from an electroplating facility containing 252.
3 g/L of sulfuric acid, 20.
9 g/L of nickel ions and small amounts of zinc, iron, copper ions, etc.
has been studied.
Heterogeneous cation-exchange membrane containing sulfo groups and heterogeneous anion-exchange membranes with different thicknesses (from 145 μm to 550 μm) and types of fixed groups (4 samples with quaternary amino groups and 1 sample with secondary and tertiary amino groups) are used.
The diffusion fluxes of sulfuric acid, nickel sulfate, and the total and osmotic fluxes of the solvent are determined.
The use of a cation-exchange membrane does not allow separation of the components, since the fluxes of both components are low and comparable in magnitude.
The use of anion-exchange membranes makes it possible to efficiently separate sulfuric acid and nickel sulfate.
At the same time, the thin dialysis membrane turns out to be the most effective, as well as the membranes with quaternary amino groups, and the membrane with secondary and tertiary amino groups proved to be the least effective.
Related Results
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Background: Annual-demand for haemodialysis-sessions in India is 3.4 Crores. To make Renal-care-services affordable to APL and free to BPL, Ministry of Health and Family Welfare la...
Comparative Study of Different Ion-Exchange Membrane Types in Diffusion Dialysis for the Separation of Sulfuric Acid and Nickel Sulfate
Comparative Study of Different Ion-Exchange Membrane Types in Diffusion Dialysis for the Separation of Sulfuric Acid and Nickel Sulfate
The possibility of using various types of ion-exchange membranes in diffusion dialysis for the separation of sulfuric acid and nickel sulfate has been evaluated. The process of the...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
FC 117TIME TRENDS IN PROBABILITY OF STARTING HOME DIALYSIS OVER A 20 YEAR PERIOD: A DUTCH REGISTRY STUDY
FC 117TIME TRENDS IN PROBABILITY OF STARTING HOME DIALYSIS OVER A 20 YEAR PERIOD: A DUTCH REGISTRY STUDY
Abstract
Background and Aims
A growing number of patients suffers from End Stage Kidney Disease(ESKD), causing a logistical and ...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
MO702DIFFERENCES IN HOSPITALISATION BETWEEN PERITONEAL DIALYSIS AND IN-CENTRE HAEMODIALYSIS PATIENTS
MO702DIFFERENCES IN HOSPITALISATION BETWEEN PERITONEAL DIALYSIS AND IN-CENTRE HAEMODIALYSIS PATIENTS
Abstract
Background and Aims
End stage kidney disease (ESKD) and dialysis treatment are associated with high morbidity, frequent...
Water Use and Water Saving Strategies in Dialysis, Room for Improvement?
Water Use and Water Saving Strategies in Dialysis, Room for Improvement?
Dialysis treatment consumes a significant amount of water and energy, which entails an important waste management effort. Those variables play a relevant role on the total cost of ...
Sample preparation using membrane dialysis for determination of Iodide Ion in milk and egg samples
Sample preparation using membrane dialysis for determination of Iodide Ion in milk and egg samples
The sample preparation using membrane dialysis for iodide determination in milk and egg samples was developed. Thio-nit method was used for iodide detection. Several dialysis confi...

