Javascript must be enabled to continue!
The role of hydrogen peroxide in hip arthroplasty: A narrative review
View through CrossRef
Hydrogen peroxide has become more commonly used in hip arthroplasties due to high risk of periprosthetic infections. Its purported roles include irrigation, haemostasis, reduction of aseptic loosening and attachment of antibiotics. However, current literature does not provide conclusive evidence on the efficacy of hydrogen peroxide in preventing aseptic loosening, with some controversy around whether it in fact contributes to aseptic loosening. The complications of hydrogen peroxide across medicine are well distinguished; however, the risks within orthopaedic surgery and hip arthroplasties are not well known. Beyond cytotoxicity, the most dangerous reported risk associated with hydrogen peroxide in hip arthroplasties was an oxygen embolism in an unvented femoral canal and acrylic bone cement, consequentially leading to cardiac arrest. However, it may be inappropriate to solely attribute the oxygen embolism to the use of hydrogen peroxide and thus if used appropriately, hydrogen peroxide may have a justifiable role in hip arthroplasty surgery. In this narrative review, we present the current uses of hydrogen peroxide while evaluating its associated risks. We have summarised the key indications and aggregated recommendations to provide guidelines for the use of hydrogen peroxide in hip arthroplasty.
Title: The role of hydrogen peroxide in hip arthroplasty: A narrative review
Description:
Hydrogen peroxide has become more commonly used in hip arthroplasties due to high risk of periprosthetic infections.
Its purported roles include irrigation, haemostasis, reduction of aseptic loosening and attachment of antibiotics.
However, current literature does not provide conclusive evidence on the efficacy of hydrogen peroxide in preventing aseptic loosening, with some controversy around whether it in fact contributes to aseptic loosening.
The complications of hydrogen peroxide across medicine are well distinguished; however, the risks within orthopaedic surgery and hip arthroplasties are not well known.
Beyond cytotoxicity, the most dangerous reported risk associated with hydrogen peroxide in hip arthroplasties was an oxygen embolism in an unvented femoral canal and acrylic bone cement, consequentially leading to cardiac arrest.
However, it may be inappropriate to solely attribute the oxygen embolism to the use of hydrogen peroxide and thus if used appropriately, hydrogen peroxide may have a justifiable role in hip arthroplasty surgery.
In this narrative review, we present the current uses of hydrogen peroxide while evaluating its associated risks.
We have summarised the key indications and aggregated recommendations to provide guidelines for the use of hydrogen peroxide in hip arthroplasty.
Related Results
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Cometary Physics Laboratory: spectrophotometric experiments
Cometary Physics Laboratory: spectrophotometric experiments
<p><strong><span dir="ltr" role="presentation">1. Introduction</span></strong&...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fragility, with a 22% one...
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
AbstractObjectiveTo describe disability in individuals with hip arthroplasty and its evolution over 2 years compared with that in the general population, and to compare the degree ...
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
AIM: To investigate the risk factors of perioperative transfusion in hip arthroplasty and to construct a nomogram model to predict the risk of transfusion. METHODS: A total of 120 ...
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Aims Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic looseni...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract
Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...
Effect of hydrogen peroxide on growth of Candida, Cryptococcus, and other yeasts in simulated blood culture bottles
Effect of hydrogen peroxide on growth of Candida, Cryptococcus, and other yeasts in simulated blood culture bottles
The addition of hydrogen peroxide to blood contained in liquid culture medium increased the dissolved-O2 partial pressure in direct proportion to the volume injected. The effect of...

