Hydrodynamic Noise of Pulsating Jets through Bileaflet Mechanical Mitral Valve
View through CrossRef
Experimental research results of hydrodynamic noise of pulsating flow through a bileaflet mechanical mitral valve are presented. The pulsating flow of pure water corresponds to the diastolic mode of the cardiac rhythm heart. The valve was located between the model of the left atrium and the model of the left ventricle of the heart. A coordinate device, on which a block of miniature sensors of absolute pressure and pressure fluctuations was installed, was located inside the model of the left ventricle. It is found that the hydrodynamic noise of the pulsating side jet of the semiclosed valve is higher than for the open valve. The pressure fluctuation levels gradually decrease with the removal from the mitral valve. It is established that at the second harmonic of the pulsating flow frequency, the spectral levels of the hydrodynamic noise of the semiclosed bileaflet mechanical mitral valve are almost 5 times higher than the open valve. With the removal from the mitral valve, spectral levels of hydrodynamic noise are decreased, especially strongly at the frequency of the pulsating water flow and its higher harmonics.
Title: Hydrodynamic Noise of Pulsating Jets through Bileaflet Mechanical Mitral Valve
Description:
Experimental research results of hydrodynamic noise of pulsating flow through a bileaflet mechanical mitral valve are presented.
The pulsating flow of pure water corresponds to the diastolic mode of the cardiac rhythm heart.
The valve was located between the model of the left atrium and the model of the left ventricle of the heart.
A coordinate device, on which a block of miniature sensors of absolute pressure and pressure fluctuations was installed, was located inside the model of the left ventricle.
It is found that the hydrodynamic noise of the pulsating side jet of the semiclosed valve is higher than for the open valve.
The pressure fluctuation levels gradually decrease with the removal from the mitral valve.
It is established that at the second harmonic of the pulsating flow frequency, the spectral levels of the hydrodynamic noise of the semiclosed bileaflet mechanical mitral valve are almost 5 times higher than the open valve.
With the removal from the mitral valve, spectral levels of hydrodynamic noise are decreased, especially strongly at the frequency of the pulsating water flow and its higher harmonics.
Related Results
Statistical Characteristics of Flow Field through Open and Semi-Closed Bileaflet Mechanical Heart Valve
Statistical Characteristics of Flow Field through Open and Semi-Closed Bileaflet Mechanical Heart Valve
The formation of thrombi on the streamlined surface of the bileaflet mechanical heart valves is one of the main disadvantages of such valves. Thrombi block the valve leaflets and d...
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Objective: To evaluate accuracy of mitral leaflet separation index for the determination of mitral stenosis severity in patients with rheumatic mitral stenosis.
Method: The prospec...
P1720 Hammock mitral valve, a challenging echocardiographic diagnosis
P1720 Hammock mitral valve, a challenging echocardiographic diagnosis
Abstract
We report a 43 year-old female with a past TTE echocardiography of rheumatic valve disease performed in her district h...
89 Simultaneous ocurrence of hammock mitral valve and no-compaction cardiomyopathy
89 Simultaneous ocurrence of hammock mitral valve and no-compaction cardiomyopathy
Abstract
We report a 62-year-old man with a past medical history of dyslipidemia, paranoid schizophrenia and permanent atrial f...
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Background: Mitral valve regurgitation due to degenerative valve disease is a common disease affecting about 2% of the population, mainly in developed countries [2],[6]. Medical t...
Mitral valve surgery after a failed MitraClip procedure
Mitral valve surgery after a failed MitraClip procedure
Abstract
OBJECTIVES
Among patients undergoing transcatheter mitral valve repair with the MitraClip device, a relevant proportion...
P837 Isolated cleft posterior mitral valve leaflet
P837 Isolated cleft posterior mitral valve leaflet
Abstract
A 78-year-old man with a history of hypertension and diabetes mellitus was referred to the ER of our hospital due to an episode of shortness of breath of ne...
Predictors of maternal and fetal outcomes of pregnant women with mitral stenosis
Predictors of maternal and fetal outcomes of pregnant women with mitral stenosis
AbstractBackgroundValvular heart disease, in particular mitral stenosis, is associated with unfavorable pregnancy outcomes. Data on maternal and fetal outcomes of pregnant women wi...