Indoor Air Quality in an Orthopedic Hospital from Romania

View through CrossRef
Inside hospitals, there is a trend of increasing levels of air pollutants. However, only the indoor air quality in operating theaters is carefully monitored. Therefore, we set the goal of this study to evaluate the indoor air quality in areas of an orthopedics department and to compare the indoor air quality indices that characterize these areas. We used a monitoring system based on the Internet of Things with uRADMonitor model A3 sensors, with which we prospectively measured indoor air quality in the facilities of the orthopedic emergency hospital of Targu Mures in Romania, between 1 February 2023, and 31 January 2024. The primary target pollutants investigated in the emergency room, outpatient room and ward were carbon dioxide (CO2), nitrogen dioxide (NO2), volatile organic compounds (VOCs) and particles with a diameter smaller than 2.5 μm (PM2.5). We compared the effectiveness of the intervention for emergency rooms where air purifiers were working or not. The concentrations of CO2, VOCs and PM2.5 were significantly higher in the emergency room than in the outpatient room or ward. The indoor air quality was worst in winter, when the CO2, NO2 and VOC concentrations were at their highest. Air purifiers can help reduce the concentration of PM2.5 in emergency rooms. Medical staff and patients in orthopedic hospitals, especially in emergency rooms, are frequently exposed to polluted ambient air, which can affect their health. Orthopedic medical practice guidelines should address issues relating to the protection of personnel through the application of measures to improve indoor air quality.
Title: Indoor Air Quality in an Orthopedic Hospital from Romania
Description:
Inside hospitals, there is a trend of increasing levels of air pollutants.
However, only the indoor air quality in operating theaters is carefully monitored.
Therefore, we set the goal of this study to evaluate the indoor air quality in areas of an orthopedics department and to compare the indoor air quality indices that characterize these areas.
We used a monitoring system based on the Internet of Things with uRADMonitor model A3 sensors, with which we prospectively measured indoor air quality in the facilities of the orthopedic emergency hospital of Targu Mures in Romania, between 1 February 2023, and 31 January 2024.
The primary target pollutants investigated in the emergency room, outpatient room and ward were carbon dioxide (CO2), nitrogen dioxide (NO2), volatile organic compounds (VOCs) and particles with a diameter smaller than 2.
5 μm (PM2.
5).
We compared the effectiveness of the intervention for emergency rooms where air purifiers were working or not.
The concentrations of CO2, VOCs and PM2.
5 were significantly higher in the emergency room than in the outpatient room or ward.
The indoor air quality was worst in winter, when the CO2, NO2 and VOC concentrations were at their highest.
Air purifiers can help reduce the concentration of PM2.
5 in emergency rooms.
Medical staff and patients in orthopedic hospitals, especially in emergency rooms, are frequently exposed to polluted ambient air, which can affect their health.
Orthopedic medical practice guidelines should address issues relating to the protection of personnel through the application of measures to improve indoor air quality.

Related Results

Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
The elderly residing in nursing homes are typically more advanced in age, have more health issues, and spend more time indoors than other elderly people. This study explored the in...
Indoor and outdoor air quality relationships modelling
Indoor and outdoor air quality relationships modelling
Particulate matter (PM) related ambient pollution has emerged as one of the most significant environmental and human health issues during the last decades. Thus, ambient PM concent...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Revealing Long-Term Indoor Air Quality Prediction: An Intelligent Informer-Based Approach
Revealing Long-Term Indoor Air Quality Prediction: An Intelligent Informer-Based Approach
Indoor air pollution is an urgent issue, posing a significant threat to the health of indoor workers and residents. Individuals engaged in indoor occupations typically spend an ave...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Navigating dust storms and urban living: an analysis of particulate matter infiltration in Dubai’s residences
Navigating dust storms and urban living: an analysis of particulate matter infiltration in Dubai’s residences
In response to the growing concern of air pollution in Dubai, this study was undertaken to measure and analyze indoor and outdoor particulate matter (PM) concentrations in resident...
Radiation exposure and fluoroscopically-guided interventional procedures among orthopedic surgeons in South Korea
Radiation exposure and fluoroscopically-guided interventional procedures among orthopedic surgeons in South Korea
AbstractBackgroundThe use of fluoroscopically-guided interventional (FGI) procedures by orthopedic surgeons has been increasing. This study aimed to investigate the occupational ra...

Back to Top