Javascript must be enabled to continue!
Analysis of comfort band for adaptive model in Japanese office buildings
View through CrossRef
Thermal comfort has been discussed subject since 1930. The pattern of the way of global warming and issues regarding the energy has influenced the rise in the interest of this subject lately. This study aims to develop comfort band for adaptive model for Japanese office buildings as the global standard do not include the databases from the Japanese buildings and so might not be applicable in the context of Japan. Field data was conducted in 17 mixed-mode (MM) office buildings located in Tokyo and Kanagawa of Japan. Measurements like air temperature, relative humidity, and other environmental factors was carried out along with the occupant’s thermal comfort survey. Probit analysis method was adapted to estimate comfort band. Result suggests that indoor globe temperature ranged from 22.0-27.0 °C during the field survey period. The comfort band obtained by the difference between the indoor globe temperature and comfort temperature (Δt) are ±2.0°C at 90% and ±2.5°C at 80% which were applied in proposed adaptive model for Japanese office buildings.
Title: Analysis of comfort band for adaptive model in Japanese office buildings
Description:
Thermal comfort has been discussed subject since 1930.
The pattern of the way of global warming and issues regarding the energy has influenced the rise in the interest of this subject lately.
This study aims to develop comfort band for adaptive model for Japanese office buildings as the global standard do not include the databases from the Japanese buildings and so might not be applicable in the context of Japan.
Field data was conducted in 17 mixed-mode (MM) office buildings located in Tokyo and Kanagawa of Japan.
Measurements like air temperature, relative humidity, and other environmental factors was carried out along with the occupant’s thermal comfort survey.
Probit analysis method was adapted to estimate comfort band.
Result suggests that indoor globe temperature ranged from 22.
0-27.
0 °C during the field survey period.
The comfort band obtained by the difference between the indoor globe temperature and comfort temperature (Δt) are ±2.
0°C at 90% and ±2.
5°C at 80% which were applied in proposed adaptive model for Japanese office buildings.
Related Results
Zero to hero
Zero to hero
Western images of Japan tell a seemingly incongruous story of love, sex and marriage – one full of contradictions and conflicting moral codes. We sometimes hear intriguing stories ...
Spin-wave band gaps created by rotating square rods in triangular lattice magnonic crystals
Spin-wave band gaps created by rotating square rods in triangular lattice magnonic crystals
Recently, magnonic crystals which are the magnetic counterparts of photonic crystals or phononic crystals are becoming a hot area of research. In this paper, band structure of two-...
Study on behavioral adaptation for the adaptive thermal comfort and energy saving in Japanese office buildings
Study on behavioral adaptation for the adaptive thermal comfort and energy saving in Japanese office buildings
Office workers use a variety of adaptive opportunities to regulate their indoor thermal environment. The behavioural adaptations such as window opening, clothing adjustments, and u...
Comparative assessment of environmental and post- occupancy evaluation of green buildings vs conventional buildings
Comparative assessment of environmental and post- occupancy evaluation of green buildings vs conventional buildings
Due to increasing office space demand and rising rental rates, stakeholders seek cost-effective alternatives that align with sustainability goals. Therefore, green building offers ...
Study on thermal comfort zone in MM and HVAC office buildings in Aichi prefecture based on daily survey
Study on thermal comfort zone in MM and HVAC office buildings in Aichi prefecture based on daily survey
Thermal comfort has been a discussed subject since 1930. Researchers have looked into understanding the thermal comfort of the occupant’s weather at home, offices, educational ins...
SOCIALIZATION OF THERMAL COMFORT STANDARDS AT SMKN 4 SOUTH TANGERANG
SOCIALIZATION OF THERMAL COMFORT STANDARDS AT SMKN 4 SOUTH TANGERANG
Vocational High School (SMK) is a formal education unit that provides education that prepares students to work in specific fields. Students can continue their vocational education ...
Effectiveness of Comfort Theory Model Based on Holistic Care for Hospitalized Children with Sickle Cell Disease Crises
Effectiveness of Comfort Theory Model Based on Holistic Care for Hospitalized Children with Sickle Cell Disease Crises
Background: Children’s experience of hospital when suffering acute sickle cell crises can be improved by a comfort approach to nursing care. Aim and Design: The true experimental d...
Occupancy Comfort Evaluation in Green Building Rating Tools in Malaysia: A Comparative Review
Occupancy Comfort Evaluation in Green Building Rating Tools in Malaysia: A Comparative Review
Passive design strategy is the approach that maximizing utilization of natural resources to achieve occupancy comfort which covers the thermal comfort, visual comfort and acoustic ...

