Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Infrared PAR-CLIP v1

View through CrossRef
Crosslinking and immunoprecipitation (CLIP) protocol based on 4-thiouridine incorporation and sequencing to determine binding sites of RNA-binding proteins (RBPs). This protocol has been used for the manuscript "Control of immediate early gene expression by CPEB4 repressor complex-mediated mRNA degradation" by Poetz, Lebedeva et al. , Genome Biology 2022. Based on the following protocols. - easy CLIP Porter DF, Miao W, Yang X, Goda GA, Ji AL, Donohue LKH, Aleman MM, Dominguez D, Khavari PA. easyCLIP analysis of RNA-protein interactions incorporating absolute quantification. Nat Commun. 2021 Mar 10;12(1):1569. doi: 10.1038/s41467-021-21623-4. PMID: 33692367; PMCID: PMC7946914. - PAR-CLIP Hafner M, Landthaler M, Burger L, Khorshid M, Hausser J, Berninger P, Rothballer A, Ascano M Jr, Jungkamp AC, Munschauer M, Ulrich A, Wardle GS, Dewell S, Zavolan M, Tuschl T. Transcriptome-wide identification of RNA-binding protein and microRNA target sites by PAR-CLIP. Cell. 2010 Apr 2;141(1):129-41. doi: 10.1016/j.cell.2010.03.009. PMID: 20371350; PMCID: PMC2861495. - iCLIP Huppertz I, Attig J, D'Ambrogio A, Easton LE, Sibley CR, Sugimoto Y, Tajnik M, König J, Ule J. iCLIP: protein-RNA interactions at nucleotide resolution. Methods. 2014 Feb;65(3):274-87. doi: 10.1016/j.ymeth.2013.10.011. Epub 2013 Oct 25. PMID: 24184352; PMCID: PMC3988997. How to analyze the data: - For the general pipeline to map CLIP-seq reads, see https://github.com/ohlerlab/clip_pipeline or https://github.com/slebedeva/CLIP_mapping. For specific pipeline to map the data from this protocol, look into - https://github.com/slebedeva/CPEB4_public. - For the Ohler lab tool to call CLIP peaks, see https://github.com/ohlerlab/omniCLIP or https://github.com/slebedeva/omniCLIP. - For the Ohler lab deep learning tool to predict RBP binding sites based on CLIP peaks see https://github.com/ohlerlab/DeepRiPe.
Springer Science and Business Media LLC
Title: Infrared PAR-CLIP v1
Description:
Crosslinking and immunoprecipitation (CLIP) protocol based on 4-thiouridine incorporation and sequencing to determine binding sites of RNA-binding proteins (RBPs).
This protocol has been used for the manuscript "Control of immediate early gene expression by CPEB4 repressor complex-mediated mRNA degradation" by Poetz, Lebedeva et al.
, Genome Biology 2022.
Based on the following protocols.
- easy CLIP Porter DF, Miao W, Yang X, Goda GA, Ji AL, Donohue LKH, Aleman MM, Dominguez D, Khavari PA.
easyCLIP analysis of RNA-protein interactions incorporating absolute quantification.
Nat Commun.
2021 Mar 10;12(1):1569.
doi: 10.
1038/s41467-021-21623-4.
PMID: 33692367; PMCID: PMC7946914.
- PAR-CLIP Hafner M, Landthaler M, Burger L, Khorshid M, Hausser J, Berninger P, Rothballer A, Ascano M Jr, Jungkamp AC, Munschauer M, Ulrich A, Wardle GS, Dewell S, Zavolan M, Tuschl T.
Transcriptome-wide identification of RNA-binding protein and microRNA target sites by PAR-CLIP.
Cell.
2010 Apr 2;141(1):129-41.
doi: 10.
1016/j.
cell.
2010.
03.
009.
PMID: 20371350; PMCID: PMC2861495.
- iCLIP Huppertz I, Attig J, D'Ambrogio A, Easton LE, Sibley CR, Sugimoto Y, Tajnik M, König J, Ule J.
iCLIP: protein-RNA interactions at nucleotide resolution.
Methods.
2014 Feb;65(3):274-87.
doi: 10.
1016/j.
ymeth.
2013.
10.
011.
Epub 2013 Oct 25.
PMID: 24184352; PMCID: PMC3988997.
How to analyze the data: - For the general pipeline to map CLIP-seq reads, see https://github.
com/ohlerlab/clip_pipeline or https://github.
com/slebedeva/CLIP_mapping.
For specific pipeline to map the data from this protocol, look into - https://github.
com/slebedeva/CPEB4_public.
- For the Ohler lab tool to call CLIP peaks, see https://github.
com/ohlerlab/omniCLIP or https://github.
com/slebedeva/omniCLIP.
- For the Ohler lab deep learning tool to predict RBP binding sites based on CLIP peaks see https://github.
com/ohlerlab/DeepRiPe.

Related Results

Electromagnetic and modeling analyses of an implanted device at 3 and 7 Tesla
Electromagnetic and modeling analyses of an implanted device at 3 and 7 Tesla
AbstractPurposeTo study the specific absorption rates (SAR) associated with implantable devices at 3T and 7T.Materials and MethodsStudies were carried out utilizing a finite differ...
An Infrared Sequence Image Generating Method for Target Detection and Tracking
An Infrared Sequence Image Generating Method for Target Detection and Tracking
Training infrared target detection and tracking models based on deep learning requires a large number of infrared sequence images. The cost of acquisition real infrared target sequ...
Intraneobladder Hem-o-Lok Migration with Stone Formation after Orthotopic Neobladder Cystectomy
Intraneobladder Hem-o-Lok Migration with Stone Formation after Orthotopic Neobladder Cystectomy
Introduction. Laparoscopic and robot-assisted laparoscopic surgery are widely performed in urology field, so Hem-o-Lok clips are thus extensively used in the laparoscopic procedure...
Solution-processed quantum dot infrared lasers
Solution-processed quantum dot infrared lasers
(English) Colloidal semiconductors quantum dots (CQDs) have emerged as a promising solutionprocessed gain material that can be engineered via low-cost and scalable chemical techniq...
Graphene–aluminum nitride NEMS resonant infrared detector
Graphene–aluminum nitride NEMS resonant infrared detector
AbstractThe use of micro-/nanoelectromechanical resonators for the room temperature detection of electromagnetic radiation at infrared frequencies has recently been investigated, s...
Intraoperative microvascular Doppler monitoring in intracranial aneurysm surgery
Intraoperative microvascular Doppler monitoring in intracranial aneurysm surgery
Background Surgical treatment of intracranial aneurysms is often compromised by incomplete exclusion of the aneurysm or stenosis of parent vessels. Intraoperative micro...
POLYMERIC CLIP VERSUS ENDOLOOP FOR STUMP CLOSURE IN LAPAROSCOPIC APPENDICECTOMY-A RANDOMISED CONTROL TRIAL
POLYMERIC CLIP VERSUS ENDOLOOP FOR STUMP CLOSURE IN LAPAROSCOPIC APPENDICECTOMY-A RANDOMISED CONTROL TRIAL
Objectives:: In laparoscopic appendicectomy, stump closure can be done by various methods such as endoloop, extracorporeal knots, intracorporeal ligatures, and gastrointestinal sta...
Far-Infrared Emission of Filled Fabric by Sweat
Far-Infrared Emission of Filled Fabric by Sweat
In this experiment, use of far infrared filled fabric of instillation of sweat on the man the purpose of detecting artificial sweat on the far-infrared radiation rate of fiber infl...

Back to Top