Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Increased pin diameter improves torsional stability in supracondylar humerus fractures: An experimental study

View through CrossRef
Background Pediatric supracondylar humerus fractures are the most common elbow fractures seen in children, and account for 16 % of all pediatric fractures. Closed reduction and percutaneous pin fixation is the current treatment technique of choice for displaced supracondylar fractures of the distal humerus in children. The purpose of this study was to determine whether pin diameter affects the torsional strength of supracondylar humerus fractures treated by closed reduction and pin fixation. Methods Pediatric sawbone humeri simulating a Gartland type III fracture were utilized. Four different pin configurations were compared. Specimens were subjected to a torsional load producing internal rotation of the distal fragment. The stability provided by 1.25- and 1.6-mm pins was compared. Results The amount of torque required to produce 15° and 25° of rotation was greater using larger diameter pins in all models tested. The two lateral and one medial large pin (1.6 mm) configuration required the highest amount of torque to produce both 15° and 25° of rotation. Conclusions In a synthetic pediatric humerus model of supracondylar humerus fractures, larger diameter pins (1.6 mm) provided increased stability compared with small diameter pins (1.25 mm). Fixation using larger diameter pins created a stronger construct and improved the strength of fixation.
Title: Increased pin diameter improves torsional stability in supracondylar humerus fractures: An experimental study
Description:
Background Pediatric supracondylar humerus fractures are the most common elbow fractures seen in children, and account for 16 % of all pediatric fractures.
Closed reduction and percutaneous pin fixation is the current treatment technique of choice for displaced supracondylar fractures of the distal humerus in children.
The purpose of this study was to determine whether pin diameter affects the torsional strength of supracondylar humerus fractures treated by closed reduction and pin fixation.
Methods Pediatric sawbone humeri simulating a Gartland type III fracture were utilized.
Four different pin configurations were compared.
Specimens were subjected to a torsional load producing internal rotation of the distal fragment.
The stability provided by 1.
25- and 1.
6-mm pins was compared.
Results The amount of torque required to produce 15° and 25° of rotation was greater using larger diameter pins in all models tested.
The two lateral and one medial large pin (1.
6 mm) configuration required the highest amount of torque to produce both 15° and 25° of rotation.
Conclusions In a synthetic pediatric humerus model of supracondylar humerus fractures, larger diameter pins (1.
6 mm) provided increased stability compared with small diameter pins (1.
25 mm).
Fixation using larger diameter pins created a stronger construct and improved the strength of fixation.

Related Results

COMPARISON OF TWO TECHNIQUES OF TREATING GARTLAND TYPE III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
COMPARISON OF TWO TECHNIQUES OF TREATING GARTLAND TYPE III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
Background: Supracondylar fractures of humerus are one of the largest sources of serious problems and treatment controversy in childhood fractures. The advantages and disadvantages...
A study on management of paediatric supracondylar humerus fractures with lateral percutaneous Kirschner wire fixation
A study on management of paediatric supracondylar humerus fractures with lateral percutaneous Kirschner wire fixation
<p class="abstract"><strong>Background:</strong> Supracondylar fracture of the humerus in children is a common injury encountered in orthopaedic practice. Undispl...
Influence of structural torsional degree of freedom on nose landing gear shimmy
Influence of structural torsional degree of freedom on nose landing gear shimmy
Abstract The structural characteristic of combining a maneuvering mechanism and a shimmy damper into a single component is present in the nose landing gear of large civil a...
<b>Functional Outcome of Percutaneous Pining in Gartland Type III Supracondylar Humerus Fractures</b>
<b>Functional Outcome of Percutaneous Pining in Gartland Type III Supracondylar Humerus Fractures</b>
Background: Supracondylar fractures of the humerus are the most common pediatric elbow injuries, accounting for nearly two-thirds of cases, with Gartland type III representing the ...
OUTCOME OF CROSSED K-WIRES WITH LATERAL K-WIRES FOR TYPE-III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
OUTCOME OF CROSSED K-WIRES WITH LATERAL K-WIRES FOR TYPE-III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
Background and Objectives: Elbow is the most common site of fractures in children. It accounts for approximately 60% of all injuries in children. These fractures are caused by dire...
Surgical management of proximal humerus fracture treated with locking compression plate
Surgical management of proximal humerus fracture treated with locking compression plate
<p class="abstract"><strong>Background:</strong> Proximal humerus fractures accounts for about 4 to 5% of all fractures.  Treatment of unstable, displaced, and co...
Nail-plate Combination Treatment of Ipsilateral Humeral Shaft and Distal Humerus Fractures – A Case Report
Nail-plate Combination Treatment of Ipsilateral Humeral Shaft and Distal Humerus Fractures – A Case Report
Introduction: Humeral shaft and distal humerus fractures have several different treatment options, including plate fixation and intramedullary nailing. Each has its own benefits, b...