Javascript must be enabled to continue!
Case Report: STENT DISLODGEDMENT
View through CrossRef
Male 61 years old who presented with stable angina since 1 month ago, with Risk factor of CAD: hypertension, Dyslipidemia and heavy smoker. The ECG showed inferior old myocardial infarction. Diagnostic coronary angiography found: bifurcatio lesion at distal LMCA with significant stenosis 60% at the distal LM and 85% at the osteal LCx (Medina score 1-1-0), high D1 and diffuse disease with maximal stenosis 85% at the distal LAD after D2, Significant stenosis 85% at the osteal LCx and CTO at the distal after OM1, diffuse disease with maximal stenosis 85% at the mid RCA. A 6-Fr JR 4.0 guiding catheter (Launcher, Medtronic) was engaged into the right coronary artery ostium via the femoral artery. GW pilot 50 (Hi-Torque Pilot 50) inserted to distal RCA. Perform Balloon support by Saphire II inserted to mid RCA and dilated, after that perform balloon to proximal RCA and dilated. Stent DES Firebird II (Rapamycin) to mid RCA and dilated. Stent BMS Apollo 3.0x36 mm inserted to proximal-mid RCA, overlapping with previous stent, but was loss or dislodged and insert to the guiding catheter. BMS stent was pulled out with small balloon ex stent. GC 6F 4.0 inserted to ascending Aorta and engaged at ostium RCA. BMS stent Arthos PICO 3.0x 34 mm inserted to proximal-mid RCA, overlapping with previous stent and dilated. Final angiography confirmed successful pull out of loss stent and dilation of the RCA.
Title: Case Report: STENT DISLODGEDMENT
Description:
Male 61 years old who presented with stable angina since 1 month ago, with Risk factor of CAD: hypertension, Dyslipidemia and heavy smoker.
The ECG showed inferior old myocardial infarction.
Diagnostic coronary angiography found: bifurcatio lesion at distal LMCA with significant stenosis 60% at the distal LM and 85% at the osteal LCx (Medina score 1-1-0), high D1 and diffuse disease with maximal stenosis 85% at the distal LAD after D2, Significant stenosis 85% at the osteal LCx and CTO at the distal after OM1, diffuse disease with maximal stenosis 85% at the mid RCA.
A 6-Fr JR 4.
0 guiding catheter (Launcher, Medtronic) was engaged into the right coronary artery ostium via the femoral artery.
GW pilot 50 (Hi-Torque Pilot 50) inserted to distal RCA.
Perform Balloon support by Saphire II inserted to mid RCA and dilated, after that perform balloon to proximal RCA and dilated.
Stent DES Firebird II (Rapamycin) to mid RCA and dilated.
Stent BMS Apollo 3.
0x36 mm inserted to proximal-mid RCA, overlapping with previous stent, but was loss or dislodged and insert to the guiding catheter.
BMS stent was pulled out with small balloon ex stent.
GC 6F 4.
0 inserted to ascending Aorta and engaged at ostium RCA.
BMS stent Arthos PICO 3.
0x 34 mm inserted to proximal-mid RCA, overlapping with previous stent and dilated.
Final angiography confirmed successful pull out of loss stent and dilation of the RCA.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Chest Wall Hydatid Cysts: A Systematic Review
Chest Wall Hydatid Cysts: A Systematic Review
Abstract
Introduction
Given the rarity of chest wall hydatid disease, information on this condition is primarily drawn from case reports. Hence, this study systematically reviews t...
CLINICAL APPLICATION OF DOMESTIC LONG BIODEGRADABLE POLYMER COATED SIROLIMUS ELUTING STENTS FOR TREATMENT OF LONG CORONARY ARTERY LESIONS
CLINICAL APPLICATION OF DOMESTIC LONG BIODEGRADABLE POLYMER COATED SIROLIMUS ELUTING STENTS FOR TREATMENT OF LONG CORONARY ARTERY LESIONS
Objectives
To evaluate the efficacy and safety of domestic long biodegradable polymer coated sirolimus eluting stents (Excel stent, Shandong JW) for treatment of ...
Minimum stent area, stent expansion and ultrasonic flow ratio post pci: insights from multivessel talent trial
Minimum stent area, stent expansion and ultrasonic flow ratio post pci: insights from multivessel talent trial
Abstract
Background
Ultrasonic flow ratio (UFR) is a novel method for fast computation of fractional flow reserve (FFR) from int...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Introduction: One of the popular treatment strategies for complex cerebral aneurysms with wide necks or low dome-to-neck ratios is stent-assisted coiling. The most widely used intr...
Value of stent boost imaging in decision making after coronary stenting
Value of stent boost imaging in decision making after coronary stenting
AbstractBackground: Several studies reported the comparability of digital stent enhancement techniques (including stent boost imaging) in detecting suboptimal results of coronary s...

