Javascript must be enabled to continue!
The viscoelasticity, anisotropy and location-dependence of mechanical properties of rabbit iris investigated using uniaxial tensile tests
View through CrossRef
Purpose
Abnormal iris mechanical properties have been considered to be an important cause of pupillary-block and angle-closure glaucoma. In this research, viscoelasticity, anisotropy and location-dependence of mechanical properties of rabbit iris were investigated using uniaxial tensile test.
Methods
Iris strips were taken along three directions: inner-circumferential direction (ICD), outer-circumferential direction (OCD) and radial direction (RD), respectively. Quasi-static tensile tests and stress-relaxation tests were applied on the iris strips. Then the stress-stretch data was fitted with third order Ogden model; the stress-relaxation data was fitted with the third order Prony series model. Through comparing the tangent modulus and relaxation limit of the strips from different directions and locations, the viscoelasticity, anisotropy and location-dependence of mechanical properties of rabbit iris were explored.
Results
The tangent moduli of iris at the stretch of 1.05 along ICD, OCD, and RD were 3.2 ± 1.4 kPa, 4.2 ± 2.6 kPa and 1.5 ± 0.8 kPa, respectively. Iris strips in ICD and OCD were found to have almost the same stress-relaxation behavior, and both relaxed slower than iris strips in RD.
Conclusions
The mechanical properties of the iris were nonlinear, viscoelastic, anisotropic and location-dependent. The stress growth rate of the circumferential direction iris strip is significantly lower than that of RD, and the stress relaxation rate is significantly higher than that of RD. That is, the iris is more prone to deformation in RD. This study can provide more precise iris material parameters for exploring the mechanical causes of pupillary-block.
Politechnika Wroclawska Oficyna Wydawnicza
Title: The viscoelasticity, anisotropy and location-dependence of mechanical properties of rabbit iris investigated using uniaxial tensile tests
Description:
Purpose
Abnormal iris mechanical properties have been considered to be an important cause of pupillary-block and angle-closure glaucoma.
In this research, viscoelasticity, anisotropy and location-dependence of mechanical properties of rabbit iris were investigated using uniaxial tensile test.
Methods
Iris strips were taken along three directions: inner-circumferential direction (ICD), outer-circumferential direction (OCD) and radial direction (RD), respectively.
Quasi-static tensile tests and stress-relaxation tests were applied on the iris strips.
Then the stress-stretch data was fitted with third order Ogden model; the stress-relaxation data was fitted with the third order Prony series model.
Through comparing the tangent modulus and relaxation limit of the strips from different directions and locations, the viscoelasticity, anisotropy and location-dependence of mechanical properties of rabbit iris were explored.
Results
The tangent moduli of iris at the stretch of 1.
05 along ICD, OCD, and RD were 3.
2 ± 1.
4 kPa, 4.
2 ± 2.
6 kPa and 1.
5 ± 0.
8 kPa, respectively.
Iris strips in ICD and OCD were found to have almost the same stress-relaxation behavior, and both relaxed slower than iris strips in RD.
Conclusions
The mechanical properties of the iris were nonlinear, viscoelastic, anisotropic and location-dependent.
The stress growth rate of the circumferential direction iris strip is significantly lower than that of RD, and the stress relaxation rate is significantly higher than that of RD.
That is, the iris is more prone to deformation in RD.
This study can provide more precise iris material parameters for exploring the mechanical causes of pupillary-block.
Related Results
ANISOTROPY QUANTIFICATION USING HIGH-RESOLUTION WHOLE-CORE CT-SCAN IMAGES
ANISOTROPY QUANTIFICATION USING HIGH-RESOLUTION WHOLE-CORE CT-SCAN IMAGES
Spatial anisotropy and heterogeneity in petrophysical properties can significantly affect formation evaluation of hydrocarbon bearing formations. A common example is permeability a...
Bound states in the continuum in planar anisotropic structures
Bound states in the continuum in planar anisotropic structures
Bound states in the continuum (BICs) are modes that remain radiationless though they exist in the part of the spectrum that corresponds to radiating waves. They are a general wave ...
Effect of lattice mismatch stress on magnetic domain of epitaxial single crystal (BiTm)3(GaFe)5O12 film
Effect of lattice mismatch stress on magnetic domain of epitaxial single crystal (BiTm)3(GaFe)5O12 film
Yttrium iron garnet (YIG) film is a kind of magnetic film and has been investigated extensively because of its excellent magnetic properties and various applications in different f...
AFHIRIS: African Human Iris Dataset (Version 1)
AFHIRIS: African Human Iris Dataset (Version 1)
Biometric systems remain the most widely used methods for identification and authentication purposes. Their wide acceptability has opened up more research into new application area...
Quantifying Intrinsic and Extrinsic Contributions to Elastic Anisotropy Observed in Seismic Tomography Models
Quantifying Intrinsic and Extrinsic Contributions to Elastic Anisotropy Observed in Seismic Tomography Models
<p>Large-scale seismic anisotropy inferred from seismic observations has been loosely interpreted either in terms of intrinsic anisotropy due to Crystallographic Pref...
Short Axial Length and Iris Damage Are Associated With Iris Posterior Synechiae After Descemet Membrane Endothelial Keratoplasty in Asian Eyes
Short Axial Length and Iris Damage Are Associated With Iris Posterior Synechiae After Descemet Membrane Endothelial Keratoplasty in Asian Eyes
Purpose:
To evaluate the frequency and severity of iris posterior synechiae after Descemet membrane endothelial keratoplasty (DMEK) and to investigate possible causes o...
Study of the Effect of ASP Solution Viscoelasticity on Displacement Efficiency
Study of the Effect of ASP Solution Viscoelasticity on Displacement Efficiency
Abstract
In application of Alkali-surfactant-polymer flooding, people always follow after ultra low IFT and negate the effect of ASP solution viscoelasticity on disp...
Iris manipulation during phacoemulsification: intraoperative and postoperative complications
Iris manipulation during phacoemulsification: intraoperative and postoperative complications
AIM: To quantify intraoperative and postoperative complications in complex phacoemulsification cataract extraction (phacoemulsification) with iris manipulation compared to non-comp...

