Javascript must be enabled to continue!
Flicker Emission Analysis of a Wind Farm
View through CrossRef
In this paper is presented the criteria used by UTE, with respect to the Flicker emission of power plants; considering that this is one of the quality parameters monitored at the connection node. This work is focused in the flicker emission phenomenon. It sets out the criteria used to determine the emission limits for individual users connected to the distribution network. Additionally it presents a theoretical method, based on international standards, to estimate the total emission of flicker that will produce a wind farm in the connection node. The aim of this paper is to compare the theoretical emission flicker, with the field measurements in the connection node of a power generator. Here are calculated individual emission limits and the theoretical estimation of the flicker emission from a wind farm of 10MW connected to a network of 31.5kV. Finally, these values are compared with Pst and Plt parameters, short-term flicker disturbance factor and long-term flicker disturbance factor of the installation of wind turbines, which arise from a registry conducted in the field, with real data measured in the connection node of the wind farm.
Cultech Publishing Sdn. Bhd.
Title: Flicker Emission Analysis of a Wind Farm
Description:
In this paper is presented the criteria used by UTE, with respect to the Flicker emission of power plants; considering that this is one of the quality parameters monitored at the connection node.
This work is focused in the flicker emission phenomenon.
It sets out the criteria used to determine the emission limits for individual users connected to the distribution network.
Additionally it presents a theoretical method, based on international standards, to estimate the total emission of flicker that will produce a wind farm in the connection node.
The aim of this paper is to compare the theoretical emission flicker, with the field measurements in the connection node of a power generator.
Here are calculated individual emission limits and the theoretical estimation of the flicker emission from a wind farm of 10MW connected to a network of 31.
5kV.
Finally, these values are compared with Pst and Plt parameters, short-term flicker disturbance factor and long-term flicker disturbance factor of the installation of wind turbines, which arise from a registry conducted in the field, with real data measured in the connection node of the wind farm.
Related Results
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background:
In a wind farm, the wind speed of the downstream wind turbine will be
lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Wind lidars within Dutch offshore wind farms
Wind lidars within Dutch offshore wind farms
The growing number of wind farms in the Dutch part of the North Sea [1] offers the necessity, as well as the opportunity, to measure the meteorological conditions at these location...
Contributions of flywheel systems in wind power plants
Contributions of flywheel systems in wind power plants
The stepwise replacement of conventional power plants by renewable-based ones such as wind power plants could a ect the system behaviour and planning. First, the network stability ...
Probabilistic Modeling of Structural Wind Loads and Reliability Implications Considering Wind Direction Effects in Northeast China
Probabilistic Modeling of Structural Wind Loads and Reliability Implications Considering Wind Direction Effects in Northeast China
Wind speed and wind direction are key random variables governing structural wind-load effects and reliability levels. Conventional probabilistic wind-load analyses usually derive r...
Solar wind interaction with comet 67P around perihelion
Solar wind interaction with comet 67P around perihelion
AbstractNear perihelion, when comet 67P was most active, the Rosetta spacecraft resided inside the comet induced magnetosphere. The solar wind magnetic field was still present, but...
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Recently, offshore wind farms have emerged as the most promising sector in the global renewable energy industry. The main reasons for the rapid development of offshore wind farms i...
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Recently, offshore wind farms have emerged as the most promising sector in the global renewable energy industry. The main reasons for the rapid development of offshore wind farms i...
Assessment of wind energy potential ofthe Murmansk Regionand performance of Kola wind farm
Assessment of wind energy potential ofthe Murmansk Regionand performance of Kola wind farm
The paper gives an analysis of perspectives for development of wind power generation, information on the share of wind energy in electricity generation in the world and in Russian ...