Flicker Emission Analysis of a Wind Farm

View through CrossRef
In this paper is presented the criteria used by UTE, with respect to the Flicker emission of power plants; considering that this is one of the quality parameters monitored at the connection node. This work is focused in the flicker emission phenomenon. It sets out the criteria used to determine the emission limits for individual users connected to the distribution network. Additionally it presents a theoretical method, based on international standards, to estimate the total emission of flicker that will produce a wind farm in the connection node. The aim of this paper is to compare the theoretical emission flicker, with the field measurements in the connection node of a power generator. Here are calculated individual emission limits and the theoretical estimation of the flicker emission from a wind farm of 10MW connected to a network of 31.5kV. Finally, these values are compared with Pst and Plt parameters, short-term flicker disturbance factor and long-term flicker disturbance factor of the installation of wind turbines, which arise from a registry conducted in the field, with real data measured in the connection node of the wind farm.
Title: Flicker Emission Analysis of a Wind Farm
Description:
In this paper is presented the criteria used by UTE, with respect to the Flicker emission of power plants; considering that this is one of the quality parameters monitored at the connection node.
This work is focused in the flicker emission phenomenon.
It sets out the criteria used to determine the emission limits for individual users connected to the distribution network.
Additionally it presents a theoretical method, based on international standards, to estimate the total emission of flicker that will produce a wind farm in the connection node.
The aim of this paper is to compare the theoretical emission flicker, with the field measurements in the connection node of a power generator.
Here are calculated individual emission limits and the theoretical estimation of the flicker emission from a wind farm of 10MW connected to a network of 31.
5kV.
Finally, these values are compared with Pst and Plt parameters, short-term flicker disturbance factor and long-term flicker disturbance factor of the installation of wind turbines, which arise from a registry conducted in the field, with real data measured in the connection node of the wind farm.

Related Results

Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background: In a wind farm, the wind speed of the downstream wind turbine will be lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Recently, offshore wind farms have emerged as the most promising sector in the global renewable energy industry. The main reasons for the rapid development of offshore wind farms i...
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Recently, offshore wind farms have emerged as the most promising sector in the global renewable energy industry. The main reasons for the rapid development of offshore wind farms i...
Assessment of wind energy potential ofthe Murmansk Regionand performance of Kola wind farm
Assessment of wind energy potential ofthe Murmansk Regionand performance of Kola wind farm
The paper gives an analysis of perspectives for development of wind power generation, information on the share of wind energy in electricity generation in the world and in Russian ...
Modelling and performance analysis of doubly fed induction generator wind farm
Modelling and performance analysis of doubly fed induction generator wind farm
Power generation from renewable sources like wind and sun have increased substantially owing to various challenges such as government regulations, environmental pollution and deple...
Savonius Rotor for Offshore Wind Energy Conversion
Savonius Rotor for Offshore Wind Energy Conversion
Abstract Analysis of performance is presented for wind energy conversion by a Savonius type vertical axis rotor configured for generation of electrical power. The...
Calculation Method of Instantaneous Wind Speed Spatial Distribution of Wind Farm
Calculation Method of Instantaneous Wind Speed Spatial Distribution of Wind Farm
Instantaneous wind speed spatial distribution of wind farm is the basis of the optimal control for wind turbines. A calculation method was proposed for the instantaneous wind speed...
Equivalent Modeling of Double-fed Wind Farm Based on Flow Field Characteristics
Equivalent Modeling of Double-fed Wind Farm Based on Flow Field Characteristics
The entire wind farm is regarded as a large-capacity wind turbine for modeling double-fed wind farm. The influence of flow field characteristics in the wind farm has been ignored. ...

Back to Top