Does stent strut design impact clinical outcomes: comparative safety and efficacy of Endeavor Resolute versus Resolute Integrity zotarolimus-eluting stents

View through CrossRef
Purpose Percutaneous coronary intervention is the most commonly performed method of revascularizing obstructive coronary artery disease. The impact of stent strut design on clinical outcomes remains unclear. The Endeavour Resolute (ER-ZES) and the Resolute Integrity (RI-ZES) zotarolimus-eluting stents utilize identical polymers and anti-proliferative agents, differing only in their respective strut design. This study assessed the comparative safety and efficacy of these two stents in unrestricted contemporary real-world practice. Methods A total of 542 patients were identified, corresponding to 340 ER-ZES and 480 RI-ZES. The primary endpoint was major adverse cardiac events (MACE) defined by a composite of death, nonfatal myocardial infarction and stroke. Secondary endpoints included post-procedural length of stay, in-stent restenosis, target lesion revascularization, target vessel revascularization, coronary artery bypass grafting and stent thrombosis. Results MACE occurred in 3.2% of the ER-ZES cohort and 5.0% of the RI-ZES cohort (p= 0.43). Adjusted analysis utilizing propensity score-adjusted odds ratio for MACE, was 1.37 (95% CI 0.46-4.07, p=0.57). The mortality rate (0.9% ER-ZES vs. 1.9% RI-ZES, p=0.59), non-fatal MI (2.3% ER-ZES vs. 3.1% RI-ZES, p=0.75) and stroke (0.0% ER-ZES vs. 0.3% RI-ZES, p=0.85) were not different. Additionally, there was no difference in any of secondary outcomes. Conclusions The clinical performance and safety of both ER-ZES and RI-ZES were not statistically different, despite differences in stent strut design.
Title: Does stent strut design impact clinical outcomes: comparative safety and efficacy of Endeavor Resolute versus Resolute Integrity zotarolimus-eluting stents
Description:
Purpose Percutaneous coronary intervention is the most commonly performed method of revascularizing obstructive coronary artery disease.
The impact of stent strut design on clinical outcomes remains unclear.
The Endeavour Resolute (ER-ZES) and the Resolute Integrity (RI-ZES) zotarolimus-eluting stents utilize identical polymers and anti-proliferative agents, differing only in their respective strut design.
This study assessed the comparative safety and efficacy of these two stents in unrestricted contemporary real-world practice.
Methods A total of 542 patients were identified, corresponding to 340 ER-ZES and 480 RI-ZES.
The primary endpoint was major adverse cardiac events (MACE) defined by a composite of death, nonfatal myocardial infarction and stroke.
Secondary endpoints included post-procedural length of stay, in-stent restenosis, target lesion revascularization, target vessel revascularization, coronary artery bypass grafting and stent thrombosis.
Results MACE occurred in 3.
2% of the ER-ZES cohort and 5.
0% of the RI-ZES cohort (p= 0.
43).
Adjusted analysis utilizing propensity score-adjusted odds ratio for MACE, was 1.
37 (95% CI 0.
46-4.
07, p=0.
57).
The mortality rate (0.
9% ER-ZES vs.
1.
9% RI-ZES, p=0.
59), non-fatal MI (2.
3% ER-ZES vs.
3.
1% RI-ZES, p=0.
75) and stroke (0.
0% ER-ZES vs.
0.
3% RI-ZES, p=0.
85) were not different.
Additionally, there was no difference in any of secondary outcomes.
Conclusions The clinical performance and safety of both ER-ZES and RI-ZES were not statistically different, despite differences in stent strut design.

Related Results

Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial
Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial
BACKGROUND: Limited information is available on the comparative efficacy and safety of different stent platforms in patients at high bleeding risk undergoing an abbrevi...
3D-printed polymeric bioresorbable stents for cardiovascular applications
3D-printed polymeric bioresorbable stents for cardiovascular applications
(English) Bioresorbable stents (BRS) have been envisioned as a revolution in the treatment of coronary heart disease. Ideally, stents would initially retain sufficient radial stren...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
Crush Stenting With Paclitaxel-Eluting or Sirolimus-Eluting Stents for the Treatment of Coronary Bifurcation Lesions
Crush Stenting With Paclitaxel-Eluting or Sirolimus-Eluting Stents for the Treatment of Coronary Bifurcation Lesions
Two hundred forty-six patients with 252 bifurcation lesions were enrolled into a prospective, nonrandomized study to use paclitaxel-eluting or sirolimus-eluting stent for crush ste...
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Objective This study compared the clinical efficacy and safety of homemade biodegradable polymer rapamycin-eluting stent (EXCEL TM) and durable polymer rapamycin-...

Back to Top