Three-Dimensional Nonlinear Dynamic Analysis of Base Isolated Cylindrical Steel Tank

View through CrossRef
Failure of a tank during an earthquake can result in significant financial, human, and environmental losses. Thus, their lack of resiliency against strong earthquakes may result in refinery disruption. This has the potential to have a considerable impact on any economic system. As a result, more research into the seismic performance of tank structures is required to attain the highest possible level of resistance against strong earthquakes. In this paper, we aim to look into the installation of seismic isolation systems in cylindrical steel storage tanks. A nonlinear 3D finite element model is developed with ANSYS software. Moreover, tank wall material nonlinearity, fluid-structure-interaction, and sloshing components are considered. The bilinear hysteretic LRB is used for modal and time-history analysis. In this work, three tanks with varying aspect ratios are studied: "Model A", "Model B", and "Model C". Furthermore, the fixed tank's fundamental frequencies were compared to the analytical results of the American API 650 Standard. Subsequently, the dynamic behavior response of the researched tanks to the horizontal component of the El-Centro 1940 earthquake with PGAs of 0.34g and 0.5g is investigated. As a result, the dominating frequency of the seismic isolation system is within the effective frequency range of seismically isolated systems. The results illustrate that the base isolation limits the tank wall movement with a large displacement in the isolators; the mode shape is a cantilever beam in all isolated circumstances. The total seismic response reduction in the slender tanks is greater as compared to the broad case in the base-isolated tanks. The sloshing displacement increases with an increase in the tank aspect ratio. Additionally, the isolation device eliminates tank buckling at the base and top of the tank shell during seismic excitation (elephant foot and diamond buckling). It can be concluded that the seismic isolation technique has a more significant impact on reducing the dynamic response of ground-supported tanks, particularly in taller tanks as compared to broad tanks. Doi: 10.28991/CEJ-2022-08-06-013 Full Text: PDF
Title: Three-Dimensional Nonlinear Dynamic Analysis of Base Isolated Cylindrical Steel Tank
Description:
Failure of a tank during an earthquake can result in significant financial, human, and environmental losses.
Thus, their lack of resiliency against strong earthquakes may result in refinery disruption.
This has the potential to have a considerable impact on any economic system.
As a result, more research into the seismic performance of tank structures is required to attain the highest possible level of resistance against strong earthquakes.
In this paper, we aim to look into the installation of seismic isolation systems in cylindrical steel storage tanks.
A nonlinear 3D finite element model is developed with ANSYS software.
Moreover, tank wall material nonlinearity, fluid-structure-interaction, and sloshing components are considered.
The bilinear hysteretic LRB is used for modal and time-history analysis.
In this work, three tanks with varying aspect ratios are studied: "Model A", "Model B", and "Model C".
Furthermore, the fixed tank's fundamental frequencies were compared to the analytical results of the American API 650 Standard.
Subsequently, the dynamic behavior response of the researched tanks to the horizontal component of the El-Centro 1940 earthquake with PGAs of 0.
34g and 0.
5g is investigated.
As a result, the dominating frequency of the seismic isolation system is within the effective frequency range of seismically isolated systems.
The results illustrate that the base isolation limits the tank wall movement with a large displacement in the isolators; the mode shape is a cantilever beam in all isolated circumstances.
The total seismic response reduction in the slender tanks is greater as compared to the broad case in the base-isolated tanks.
The sloshing displacement increases with an increase in the tank aspect ratio.
Additionally, the isolation device eliminates tank buckling at the base and top of the tank shell during seismic excitation (elephant foot and diamond buckling).
It can be concluded that the seismic isolation technique has a more significant impact on reducing the dynamic response of ground-supported tanks, particularly in taller tanks as compared to broad tanks.
 Doi: 10.
28991/CEJ-2022-08-06-013 Full Text: PDF.

Related Results

[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Comprehensive stiffness analysis of the cylindrical roller bearing for aircraft engines considering the radial clearance
Comprehensive stiffness analysis of the cylindrical roller bearing for aircraft engines considering the radial clearance
Purpose The rotor system supported by the cylindrical roller bearings is widely used in various fields such as aviation, space and machinery due to its importance. In the study of ...
DYNAMIC CALCULATION OF THE BALL TANK UNDER THE ACTION OF LOADS AT THE SUPPORT SUBSIDENCE
DYNAMIC CALCULATION OF THE BALL TANK UNDER THE ACTION OF LOADS AT THE SUPPORT SUBSIDENCE
The work is devoted to the study of stress-strain state (SSS) of a ball tank under the action of loads at support subsidence, to conducting static and dynamic calculation. The esse...
Tank Cleaning Process Optimization For Loading Tanks MT Bauhinia Guna Cargo Change
Tank Cleaning Process Optimization For Loading Tanks MT Bauhinia Guna Cargo Change
Suboptimal implementation of tank cleaning will produce suboptimal results and can affect loading failure. These less than optimal results are influenced by several things. Tank Cl...
Study on the Bearing Plate of Steel Clarification Tank under Earthquake
Study on the Bearing Plate of Steel Clarification Tank under Earthquake
The stress at the support structure of the clarification tank is large, which will have a certain impact on the whole clarification tank structure. The typical stress concentration...
Investigation of Sloshing in Different Tank Shapes using Smoothed Particle Hydrodynamics
Investigation of Sloshing in Different Tank Shapes using Smoothed Particle Hydrodynamics
Sloshing is the violent motion of a resonant fluid in a moving tank; when the fluid moves and interacts with the tank, the dynamic pressure from such an interaction can cause large...
Influence of the unilateral elastic base on the backbone curves of an imperfect cylindrical panel
Influence of the unilateral elastic base on the backbone curves of an imperfect cylindrical panel
This work evaluates the influence of a discontinuous unilateral elastic base and an initial geometrical imperfection on the nonlinear free vibration of cylindrical panels. The Donn...