Javascript must be enabled to continue!
Three-Dimensional Nonlinear Dynamic Analysis of Base Isolated Cylindrical Steel Tank
View through CrossRef
Failure of a tank during an earthquake can result in significant financial, human, and environmental losses. Thus, their lack of resiliency against strong earthquakes may result in refinery disruption. This has the potential to have a considerable impact on any economic system. As a result, more research into the seismic performance of tank structures is required to attain the highest possible level of resistance against strong earthquakes. In this paper, we aim to look into the installation of seismic isolation systems in cylindrical steel storage tanks. A nonlinear 3D finite element model is developed with ANSYS software. Moreover, tank wall material nonlinearity, fluid-structure-interaction, and sloshing components are considered. The bilinear hysteretic LRB is used for modal and time-history analysis. In this work, three tanks with varying aspect ratios are studied: "Model A", "Model B", and "Model C". Furthermore, the fixed tank's fundamental frequencies were compared to the analytical results of the American API 650 Standard. Subsequently, the dynamic behavior response of the researched tanks to the horizontal component of the El-Centro 1940 earthquake with PGAs of 0.34g and 0.5g is investigated. As a result, the dominating frequency of the seismic isolation system is within the effective frequency range of seismically isolated systems. The results illustrate that the base isolation limits the tank wall movement with a large displacement in the isolators; the mode shape is a cantilever beam in all isolated circumstances. The total seismic response reduction in the slender tanks is greater as compared to the broad case in the base-isolated tanks. The sloshing displacement increases with an increase in the tank aspect ratio. Additionally, the isolation device eliminates tank buckling at the base and top of the tank shell during seismic excitation (elephant foot and diamond buckling). It can be concluded that the seismic isolation technique has a more significant impact on reducing the dynamic response of ground-supported tanks, particularly in taller tanks as compared to broad tanks. Doi: 10.28991/CEJ-2022-08-06-013 Full Text: PDF
Title: Three-Dimensional Nonlinear Dynamic Analysis of Base Isolated Cylindrical Steel Tank
Description:
Failure of a tank during an earthquake can result in significant financial, human, and environmental losses.
Thus, their lack of resiliency against strong earthquakes may result in refinery disruption.
This has the potential to have a considerable impact on any economic system.
As a result, more research into the seismic performance of tank structures is required to attain the highest possible level of resistance against strong earthquakes.
In this paper, we aim to look into the installation of seismic isolation systems in cylindrical steel storage tanks.
A nonlinear 3D finite element model is developed with ANSYS software.
Moreover, tank wall material nonlinearity, fluid-structure-interaction, and sloshing components are considered.
The bilinear hysteretic LRB is used for modal and time-history analysis.
In this work, three tanks with varying aspect ratios are studied: "Model A", "Model B", and "Model C".
Furthermore, the fixed tank's fundamental frequencies were compared to the analytical results of the American API 650 Standard.
Subsequently, the dynamic behavior response of the researched tanks to the horizontal component of the El-Centro 1940 earthquake with PGAs of 0.
34g and 0.
5g is investigated.
As a result, the dominating frequency of the seismic isolation system is within the effective frequency range of seismically isolated systems.
The results illustrate that the base isolation limits the tank wall movement with a large displacement in the isolators; the mode shape is a cantilever beam in all isolated circumstances.
The total seismic response reduction in the slender tanks is greater as compared to the broad case in the base-isolated tanks.
The sloshing displacement increases with an increase in the tank aspect ratio.
Additionally, the isolation device eliminates tank buckling at the base and top of the tank shell during seismic excitation (elephant foot and diamond buckling).
It can be concluded that the seismic isolation technique has a more significant impact on reducing the dynamic response of ground-supported tanks, particularly in taller tanks as compared to broad tanks.
Doi: 10.
28991/CEJ-2022-08-06-013 Full Text: PDF.
Related Results
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Tank Cleaning Process Optimization For Loading Tanks MT Bauhinia Guna Cargo Change
Tank Cleaning Process Optimization For Loading Tanks MT Bauhinia Guna Cargo Change
Suboptimal implementation of tank cleaning will produce suboptimal results and can affect loading failure. These less than optimal results are influenced by several things. Tank Cl...
Research on Dynamics Characteristic of The Filling Liquid Tank
Research on Dynamics Characteristic of The Filling Liquid Tank
Abstract
The dynamics characteristic of the rocket tank with liquid propellant in it, which takes the large part of a carrier rocket, make a great influence to the w...
Analysis of Uneven Settlement of Large Oil Storage Tank
Analysis of Uneven Settlement of Large Oil Storage Tank
Abstract
The uneven settlement of large oil storage tank will not only cause the tank wall to be elliptical and the upper floating plate to be blocked, but also caus...
Effects of Surge Tank Geometry on the Water Hammer Phenomenon: Numerical Investigation
Effects of Surge Tank Geometry on the Water Hammer Phenomenon: Numerical Investigation
Abstract
A surge tank, as one of the most common control facilities, is applied to control head pressure level in long pressurized pipelines during the water hammer occurre...
Monitoring Sistem Ketersediaan dan Pengontrolan Pengisisan Air Secara Otomatis Pada Gedung Perkantoran Berbasis Mikrokontroler
Monitoring Sistem Ketersediaan dan Pengontrolan Pengisisan Air Secara Otomatis Pada Gedung Perkantoran Berbasis Mikrokontroler
Employees who work in offices absolutely need water, for example to wash hands, to defecate, or other household needs. Water availability must be a concern of managers. But in fact...
Seismic Vulnerability Analysis of Steel Clarification Tank
Seismic Vulnerability Analysis of Steel Clarification Tank
As a physical analysis method, susceptibility not only predicts the probability of failure of a structure under different hazard levels but also prevents disasters induced by struc...
Blast-Induced Failure Analysis of Liquid Ammonia Storage Tank
Blast-Induced Failure Analysis of Liquid Ammonia Storage Tank
Abstract
Ammonium nitrate (AN) is a widely used compound in the agriculture and mining industries that, if improperly handled, poses a significant explosive hazard, ...

