Javascript must be enabled to continue!
The Influence of Temperature on Photoresist Profiles during TEM Sample Preparation using Cryo-FIB
View through CrossRef
Abstract
Photoresist (PR) profiles tend to have deformation and shrinkage with typical transmission electron microscopy (TEM) sample preparation methods using a focused ion beam scanning electron microscope (FIB-SEM). As the temperature increases during the TEM sample preparation, it may lead to deformation and shrinkage in PR profiles. In this study, we analyze the impact when performing the sample preparation at a cold temperature using a cryo-FIB to minimize deformation and shrinkage issues. To test this methodology, the TEM sample preparation process was performed under different conditions. From these experiments, the TEM results with full cryo conditions showed that the PR line to space ratio was closest to the target, which is the sample’s real line to space ratio (1:1), and the bottom anti-reflective coating (BARC) shrinkage was minimized.
Title: The Influence of Temperature on Photoresist Profiles during TEM Sample Preparation using Cryo-FIB
Description:
Abstract
Photoresist (PR) profiles tend to have deformation and shrinkage with typical transmission electron microscopy (TEM) sample preparation methods using a focused ion beam scanning electron microscope (FIB-SEM).
As the temperature increases during the TEM sample preparation, it may lead to deformation and shrinkage in PR profiles.
In this study, we analyze the impact when performing the sample preparation at a cold temperature using a cryo-FIB to minimize deformation and shrinkage issues.
To test this methodology, the TEM sample preparation process was performed under different conditions.
From these experiments, the TEM results with full cryo conditions showed that the PR line to space ratio was closest to the target, which is the sample’s real line to space ratio (1:1), and the bottom anti-reflective coating (BARC) shrinkage was minimized.
Related Results
Large-volume FIB-SEM 3D reconstruction: An effective method for characterizing pore space of lacustrine shales
Large-volume FIB-SEM 3D reconstruction: An effective method for characterizing pore space of lacustrine shales
Focused ion beam scanning electron microscopy (FIB-SEM) is a commonly used three-dimensional (3D) pore-network reconstruction method for shales due to its unique capability in imag...
A protected inert‐gas sample manipulation and transfer environment for cryo electron microscopy and analytics
A protected inert‐gas sample manipulation and transfer environment for cryo electron microscopy and analytics
The preservation of the native sample state during manipulation and exchange between sample preparation and imaging devices is a prerequisite for artefact and contamination free st...
A comprehensive foundation model for cryo-EM image processing
A comprehensive foundation model for cryo-EM image processing
AbstractCryogenic electron microscopy (cryo-EM) has become a premier technique for high-resolution structural determination of biological macromolecules1–4. However, its widespread...
Reliability Assessment of Indium Micro Bumps for 2.5D/3D Electronic Packaging Through Cryo-Argon Milling Technique
Reliability Assessment of Indium Micro Bumps for 2.5D/3D Electronic Packaging Through Cryo-Argon Milling Technique
Indium bumps are widely used in electronic packaging for interconnecting microelectronic devices due to their low melting point of 156.6 degrees C, excellent bonding capabilities a...
Tilted Microlens Fabrication Using Nano-Magnetic Particles
Tilted Microlens Fabrication Using Nano-Magnetic Particles
Double-layer heterogeneous photoresist method will be used firstly to obtain the round photoresist column with two layers of different photoresists. Since both photoresists are the...
The Nanoworkbench: Automated Nanorobotic system inside of Scanning Electron or Focused Ion Beam Microscopes
The Nanoworkbench: Automated Nanorobotic system inside of Scanning Electron or Focused Ion Beam Microscopes
The Nanoworkbench is the first system substituting eye‐hand coordination effectively with nano‐precision in a SEM/FIB‐system. It can be imagined how technology could evolve, when t...
TEM/FIB Technical Solutions to Electron Beam Induced Radiation Damage to Low K/Ultra Low K Dielectrics in Semiconductor Failure Analysis
TEM/FIB Technical Solutions to Electron Beam Induced Radiation Damage to Low K/Ultra Low K Dielectrics in Semiconductor Failure Analysis
Abstract
Electron-beam induced radiation damage can give rise to large structural collapse and deformation of low k and ultra low k IMD in semiconductor devices, pos...
Optimization of adhesion for high throughput cryo-electron tomography of vitreous sections
Optimization of adhesion for high throughput cryo-electron tomography of vitreous sections
ABSTRACT
Cellular cryo electron tomography explores tissue and cells in their unstained flash-frozen native state, revealing in situ the structure of macromolecules tog...