Javascript must be enabled to continue!
Optimalisasi Material Utama Pada Auto Transformator 100 MVA
View through CrossRef
Autotransformator is a transformer that has primary and secondary winding with the same common winding, so that it has a lighter weight compared to ordinary power transformers. The purpose of this study is to optimize the main material used in the three-phase Auto transformer in order to get the most optimum value approaching the calculation results and to know the comparison between the calculation results and the actual use of the main material in the Auto transformer and three-phase power transformer. The main material in power transformers is copper for winding and silicon steel for cores (transformer cores). Based on this research, it can be concluded that the use of main material in Auto three-phase power transformer is less than the three-phase power transformer for the same voltage and power, the magnitude of the difference in the range of 12.5% for Copper and core (transformer core) range of 47.3% of the main material in the power transformer can.
LPPMPK - Sekolah Tinggi Teknologi Muhammadiyah Cileungsi
Title: Optimalisasi Material Utama Pada Auto Transformator 100 MVA
Description:
Autotransformator is a transformer that has primary and secondary winding with the same common winding, so that it has a lighter weight compared to ordinary power transformers.
The purpose of this study is to optimize the main material used in the three-phase Auto transformer in order to get the most optimum value approaching the calculation results and to know the comparison between the calculation results and the actual use of the main material in the Auto transformer and three-phase power transformer.
The main material in power transformers is copper for winding and silicon steel for cores (transformer cores).
Based on this research, it can be concluded that the use of main material in Auto three-phase power transformer is less than the three-phase power transformer for the same voltage and power, the magnitude of the difference in the range of 12.
5% for Copper and core (transformer core) range of 47.
3% of the main material in the power transformer can.
Related Results
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
STUDI PENGARUH PELUAHAN PARSIAL TERHADAP PENUAAN KUALITAS MINYAK TRANSFORMATOR
STUDI PENGARUH PELUAHAN PARSIAL TERHADAP PENUAAN KUALITAS MINYAK TRANSFORMATOR
Transformator merupakan peralatan yang vital dalam sistem tenaga listrik. Apabila terjadi kerusakan pada transformator dapat menyebabkan pen yaluran listrik ke konsumen dapat terga...
Endothelial dysfunction and features of nociceptive sensitivity in patients with microvascular angina
Endothelial dysfunction and features of nociceptive sensitivity in patients with microvascular angina
Abstract
Funding Acknowledgements
Type of funding sources: Public Institution(s). Main funding source(s): фГБ ОУ ВО СЗГМУ им. И....
supriyatna ANALISIS KOORDINASI ISOLASI DI GARDU INDUK KUTA TERHADAP TEGANGAN LEBIH AKIBAT SAMBARAN PETIR PADA SALURAN TRANSMISI 150 KV (Pak Supriyatna)
supriyatna ANALISIS KOORDINASI ISOLASI DI GARDU INDUK KUTA TERHADAP TEGANGAN LEBIH AKIBAT SAMBARAN PETIR PADA SALURAN TRANSMISI 150 KV (Pak Supriyatna)
Sambaran petir pada saluran transmisi 150 kV dapat menimbulkan tegangan lebih yang akan membahayakan peralatan jika tegangan tersebut melampaui tingkat isolasi dasar peralatan (TID...
Rancang Bangun Modul Pembelajaran Transformator 1 Fasa dan 3 Fasa dengan Daya 120/360 VA
Rancang Bangun Modul Pembelajaran Transformator 1 Fasa dan 3 Fasa dengan Daya 120/360 VA
Transformator adalah salah satu komponen penting dalam sistem tenaga listrik. Maka dengan begitu harus adanya pemahaman yang baik mengenai karakteristik transformator. Sehingga per...
Rancangan Tap-Changer Elektronik Pada Transformator Generator Kapasitas 66 MVA, 13,8 kV/150 kV
Rancangan Tap-Changer Elektronik Pada Transformator Generator Kapasitas 66 MVA, 13,8 kV/150 kV
Tap-changer merupakan alat bantu pada transformator daya yang berfungsi untuk mengubah perbandingan/rasio transformasi guna mendapatkan tegangan operasi sekunder yang sesuai dengan...
Analisa Kualitas Tahanan Isolasi Transformator Daya
Analisa Kualitas Tahanan Isolasi Transformator Daya
Tranformator merupakan peralatan listrik statis terdiri dari inti besi berlapis dan belitan yang dapat memindahkan dan mengubah energi listrik dari satu atau lebih rangkaian listri...
Electronic Equipment Usage on Japanese Vehicles
Electronic Equipment Usage on Japanese Vehicles
<div class="htmlview paragraph">The application of a wide assortment of electronic systems to motor vehicles currently under serious consideration in the automotive and elect...


