Javascript must be enabled to continue!
Analysis of the accuracy of the signal processing algorithm of the differential phase polarimeter
View through CrossRef
The purpose of this work is to analyze the effect of the polarimeter signal processing algorithm on the results of measurements of the optical rotation angle of the polarization plane to improve the accuracy of measurements in differential polarimetry. Methods. The paper considers the methods of polarimetry used for the analysis of optically active substances, based on the methods of phase measurements used to calculate the optical rotation angle. The expediency of using the Fourier transform to calculate the phase difference of differential polarimeter signals is noted. To analyze the error of the algorithm, mathematical modeling of the measurement information processing for various signal parameters is applied. Results. The results of the study of the effect of the bit depth of the analog-to-digital converter, the number of samples over the period of the signal and the accumulation time on the accuracy of restoring the phase difference are presented. The influence of the ratio of signal amplitudes and the level of amplitude and phase noise caused by the imperfection of the measuring system has also been investigated. Conclusion. The obtained results make it possible to optimize the operating mode and improve the accuracy of the optical rotation angle measurements using a differential phase polarimeter based on the Fourier transform.
Saratov State University
Title: Analysis of the accuracy of the signal processing algorithm of the differential phase polarimeter
Description:
The purpose of this work is to analyze the effect of the polarimeter signal processing algorithm on the results of measurements of the optical rotation angle of the polarization plane to improve the accuracy of measurements in differential polarimetry.
Methods.
The paper considers the methods of polarimetry used for the analysis of optically active substances, based on the methods of phase measurements used to calculate the optical rotation angle.
The expediency of using the Fourier transform to calculate the phase difference of differential polarimeter signals is noted.
To analyze the error of the algorithm, mathematical modeling of the measurement information processing for various signal parameters is applied.
Results.
The results of the study of the effect of the bit depth of the analog-to-digital converter, the number of samples over the period of the signal and the accumulation time on the accuracy of restoring the phase difference are presented.
The influence of the ratio of signal amplitudes and the level of amplitude and phase noise caused by the imperfection of the measuring system has also been investigated.
Conclusion.
The obtained results make it possible to optimize the operating mode and improve the accuracy of the optical rotation angle measurements using a differential phase polarimeter based on the Fourier transform.
Related Results
HIGH-SPEED COMPUTER POLARIMETER BASED ON CMOS MATRIX
HIGH-SPEED COMPUTER POLARIMETER BASED ON CMOS MATRIX
Under the conditions of the COVID-19 pandemic and a full-scale war in Ukraine, the lack of computer equipment for conducting online chemical experiments is experienced. In connecti...
Method for Estimating and Compensating the Phase Imbalance of Quadrature Signal Components
Method for Estimating and Compensating the Phase Imbalance of Quadrature Signal Components
Currently, methods of direct modulation using complex signals are widely used. A complex signal consists of in-phase I (In-phase) and quadrature Q (Quadrature) components. When a s...
Sensitive and selective polarimeter for application in crystal optics
Sensitive and selective polarimeter for application in crystal optics
A polarimeter was constructed that modulates the polarization state of a light wave at the frequencies ν1 and ν2. Depending on the property searched for, the frequencies of recorde...
Exploring Strategies for Optimizing Mobilenetv2 Performance in Classification Tasks Through Transfer Learning and Hyperparameter Tuning with A Local Dataset from Kigezi, Uganda.
Exploring Strategies for Optimizing Mobilenetv2 Performance in Classification Tasks Through Transfer Learning and Hyperparameter Tuning with A Local Dataset from Kigezi, Uganda.
Abstract
Background
Deep learning has proved to very vital in numerous applications in recent years. However, the development of a model may require access to datasets. Trainin...
A New Mathematical Model for EOR Displacements Honouring Oil Ganglia
A New Mathematical Model for EOR Displacements Honouring Oil Ganglia
Abstract
During two-phase flow in porous media non-wetting phase is present simultaneously in states of mobile connected continuum and of trapped isolated ganglia...
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
The signal detection in chaotic background has gradually become one of the research focuses in recent years. Previous research showed that the measured signals were often unavoidab...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract
Introduction
Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...

