Javascript must be enabled to continue!
Analysis of the accuracy of the signal processing algorithm of the differential phase polarimeter
View through CrossRef
The purpose of this work is to analyze the effect of the polarimeter signal processing algorithm on the results of measurements of the optical rotation angle of the polarization plane to improve the accuracy of measurements in differential polarimetry. Methods. The paper considers the methods of polarimetry used for the analysis of optically active substances, based on the methods of phase measurements used to calculate the optical rotation angle. The expediency of using the Fourier transform to calculate the phase difference of differential polarimeter signals is noted. To analyze the error of the algorithm, mathematical modeling of the measurement information processing for various signal parameters is applied. Results. The results of the study of the effect of the bit depth of the analog-to-digital converter, the number of samples over the period of the signal and the accumulation time on the accuracy of restoring the phase difference are presented. The influence of the ratio of signal amplitudes and the level of amplitude and phase noise caused by the imperfection of the measuring system has also been investigated. Conclusion. The obtained results make it possible to optimize the operating mode and improve the accuracy of the optical rotation angle measurements using a differential phase polarimeter based on the Fourier transform.
Saratov State University
Title: Analysis of the accuracy of the signal processing algorithm of the differential phase polarimeter
Description:
The purpose of this work is to analyze the effect of the polarimeter signal processing algorithm on the results of measurements of the optical rotation angle of the polarization plane to improve the accuracy of measurements in differential polarimetry.
Methods.
The paper considers the methods of polarimetry used for the analysis of optically active substances, based on the methods of phase measurements used to calculate the optical rotation angle.
The expediency of using the Fourier transform to calculate the phase difference of differential polarimeter signals is noted.
To analyze the error of the algorithm, mathematical modeling of the measurement information processing for various signal parameters is applied.
Results.
The results of the study of the effect of the bit depth of the analog-to-digital converter, the number of samples over the period of the signal and the accumulation time on the accuracy of restoring the phase difference are presented.
The influence of the ratio of signal amplitudes and the level of amplitude and phase noise caused by the imperfection of the measuring system has also been investigated.
Conclusion.
The obtained results make it possible to optimize the operating mode and improve the accuracy of the optical rotation angle measurements using a differential phase polarimeter based on the Fourier transform.
Related Results
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
The signal detection in chaotic background has gradually become one of the research focuses in recent years. Previous research showed that the measured signals were often unavoidab...
Error analysis of a rotating-metasurface polarimeter
Error analysis of a rotating-metasurface polarimeter
Polarimeters, which measure the polarization states of light directly, are essentially desired in many areas of science and technology. In our previous work, we have constructed a ...
Cholesteric liquid crystal mirror-based imaging Stokes polarimeter
Cholesteric liquid crystal mirror-based imaging Stokes polarimeter
We have developed a cholesteric liquid crystal (CLC) mirror-based innovative model for detection and visualization of images in turbid media. Due to its unique optical-polarization...
Latest advancement in image processing techniques
Latest advancement in image processing techniques
Image processing is method of performing some operations on an image, for enhancing the image or for getting some information from that image, or for some other applications is not...
A phase processor used in terahertz interferometer for tokamak
A phase processor used in terahertz interferometer for tokamak
Abstract
The commonly used phase processing techniques include coherence method, zero-crossing comparison method and FFT method. Due to the influence of noise, ampli...
Photometric properties of Ryugu and its artificial impact crater
Photometric properties of Ryugu and its artificial impact crater
Introduction:  The JAXA’s Hayabusa2 mission [1] rendezvoused with the Ryugu near Earth, C-type asteroid from June 2018 to November 2019, performing two touchdown...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...