Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fused-Silica-Aperture Thermospray Sample Introduction into Axially Viewed Inductively Coupled Plasma—Atomic Emission Spectrometry

View through CrossRef
Axially viewed inductively coupled plasma–atomic emission spectrometry (ICP-AES) has encountered a resurgence in popularity over the past few years. It has been demonstrated that 5- to 10-fold improvements in limits of detection (LODs) can be obtained with axial viewing compared to conventional side-on-viewed ICP-AES. In this report, the coupling of fused-silica-aperture thermospray (FSApT)-based sample introduction with axially viewed ICP-AES is reported, in order to combine the properties of increased sample transport and reduced LODs for FSApT with the improved detection power of axially viewed ICP-AES. When FSApT was used with the standard axial torch having a large-diameter (2.3-mm) injector, high signal and background relative standard deviations (RSDs) resulted, as compared to results for pneumatic nebulization, limiting the LOD improvements obtained with FSApT. Smaller injectors (0.8-mm and 1.5-mm i.d.) allowed RSDs for FSApT that were similar to pneumatic sample introduction levels, and larger LOD improvements (10×) resulted. Data for FSApT with axially viewed ICP-AES were also compared with data for FSApT with side-on-viewed ICP-AES, and axial viewing averaged an improvement of only a factor of 2. This small level of improvement suggests that the optical system for the axial system is not optimized for use with high-performance sample introduction. On the basis of improvement factors for FSApT with side-on viewing, FSApT with axially viewed ICP-AES averages LODs that are about 73 times better than those for the conventional side-on-viewed ICP-AES with pneumatic nebulization.
Title: Fused-Silica-Aperture Thermospray Sample Introduction into Axially Viewed Inductively Coupled Plasma—Atomic Emission Spectrometry
Description:
Axially viewed inductively coupled plasma–atomic emission spectrometry (ICP-AES) has encountered a resurgence in popularity over the past few years.
It has been demonstrated that 5- to 10-fold improvements in limits of detection (LODs) can be obtained with axial viewing compared to conventional side-on-viewed ICP-AES.
In this report, the coupling of fused-silica-aperture thermospray (FSApT)-based sample introduction with axially viewed ICP-AES is reported, in order to combine the properties of increased sample transport and reduced LODs for FSApT with the improved detection power of axially viewed ICP-AES.
When FSApT was used with the standard axial torch having a large-diameter (2.
3-mm) injector, high signal and background relative standard deviations (RSDs) resulted, as compared to results for pneumatic nebulization, limiting the LOD improvements obtained with FSApT.
Smaller injectors (0.
8-mm and 1.
5-mm i.
d.
) allowed RSDs for FSApT that were similar to pneumatic sample introduction levels, and larger LOD improvements (10×) resulted.
Data for FSApT with axially viewed ICP-AES were also compared with data for FSApT with side-on-viewed ICP-AES, and axial viewing averaged an improvement of only a factor of 2.
This small level of improvement suggests that the optical system for the axial system is not optimized for use with high-performance sample introduction.
On the basis of improvement factors for FSApT with side-on viewing, FSApT with axially viewed ICP-AES averages LODs that are about 73 times better than those for the conventional side-on-viewed ICP-AES with pneumatic nebulization.

Related Results

Fundamental Characteristics of Thermospray Aerosols and Sample Introduction for Atomic Spectrometry
Fundamental Characteristics of Thermospray Aerosols and Sample Introduction for Atomic Spectrometry
Sample introduction to inductively coupled plasma atomic emission using thermospray nebulization is studied at a fundamental level. Optimum signals and signal-to-noise ratios resul...
Matrix Effects Studies with Fused-Silica Aperture Thermospray Sample Introduction to ICP-AES
Matrix Effects Studies with Fused-Silica Aperture Thermospray Sample Introduction to ICP-AES
Matrix effects with fused-silica aperture thermospray (FSApT) sample introduction for ICP-AES are found to be higher than those for pneumatic sample introduction. The effects are c...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Mechanistic Studies of Chromium Speciation with Thermospray
Mechanistic Studies of Chromium Speciation with Thermospray
Thermospray (TSP) coupled with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) or inductively coupled plasma-mass spectrometry (ICP-MS) has been developed as a no...
Valence Discrimination Effects with Thermospray Sample Introduction: Characterization and Prevention
Valence Discrimination Effects with Thermospray Sample Introduction: Characterization and Prevention
With thermospray sample introduction for atomic spectrometry, sensitivity for certain elements can be valence-dependent (valence discrimination effect). To this point, this effect ...
Atomic electron tomography: 3D structures without crystals
Atomic electron tomography: 3D structures without crystals
BACKGROUND To understand material properties and functionality at the most fundamental level, one must know the three-dimensional (3D) positions of atoms with high prec...
Determination of Nine Elements in Sherry Wine by Inductively Coupled Plasma-Atomic Emission Spectrometry
Determination of Nine Elements in Sherry Wine by Inductively Coupled Plasma-Atomic Emission Spectrometry
Abstract A quick and simple method was developed to analyze various "fino" sherry wines for routine determination of Al, Ca, Cu, Fe, K, Mg, Mn, Na, and Zn content. T...

Back to Top