Mechanistic Studies of Chromium Speciation with Thermospray

View through CrossRef
Thermospray (TSP) coupled with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) or inductively coupled plasma-mass spectrometry (ICP-MS) has been developed as a non-chromatographic method for chromium speciation to quantitatively separate and determine two chromium oxidation states: Cr(III) and Cr(VI). The limits of detection can reach 0.5 ng/mL with ICP-AES detection and 50 pg/mL with ICP-MS detection. The basis for this speciation method is that Cr(III) can selectively and nearly quantitatively deposit inside a thermospray system as Cr2O3, while Cr(VI) does not. To fully understand the mechanism of this deposition process, four questions were investigated: is aerosol formation necessary for the reaction to occur? Does the deposition occur in the aerosol or liquid regime? Does the deposit tend to be retained on the surface of the fused silica capillary? Can the reaction be predicted from thermodynamic calculations? These studies show that this reaction happens before solvent evaporates (i.e., the liquid regime). The high temperature inside the thermospray system is the major factor triggering this reaction. At the same time, the high pressure is important for its influence on the solvent boiling point, which affects the residence time (the time that the analyte spends in the solution before the solvent evaporates) and the kinetics of the reaction. The effects of the other parameters (vaporizer length, heating length, drawn tip, etc.) on the efficiency of the deposition reaction, represented as background residual signal (BRS), were also studied.
Title: Mechanistic Studies of Chromium Speciation with Thermospray
Description:
Thermospray (TSP) coupled with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) or inductively coupled plasma-mass spectrometry (ICP-MS) has been developed as a non-chromatographic method for chromium speciation to quantitatively separate and determine two chromium oxidation states: Cr(III) and Cr(VI).
The limits of detection can reach 0.
5 ng/mL with ICP-AES detection and 50 pg/mL with ICP-MS detection.
The basis for this speciation method is that Cr(III) can selectively and nearly quantitatively deposit inside a thermospray system as Cr2O3, while Cr(VI) does not.
To fully understand the mechanism of this deposition process, four questions were investigated: is aerosol formation necessary for the reaction to occur? Does the deposition occur in the aerosol or liquid regime? Does the deposit tend to be retained on the surface of the fused silica capillary? Can the reaction be predicted from thermodynamic calculations? These studies show that this reaction happens before solvent evaporates (i.
e.
, the liquid regime).
The high temperature inside the thermospray system is the major factor triggering this reaction.
At the same time, the high pressure is important for its influence on the solvent boiling point, which affects the residence time (the time that the analyte spends in the solution before the solvent evaporates) and the kinetics of the reaction.
The effects of the other parameters (vaporizer length, heating length, drawn tip, etc.
) on the efficiency of the deposition reaction, represented as background residual signal (BRS), were also studied.

Related Results

Fundamental Characteristics of Thermospray Aerosols and Sample Introduction for Atomic Spectrometry
Fundamental Characteristics of Thermospray Aerosols and Sample Introduction for Atomic Spectrometry
Sample introduction to inductively coupled plasma atomic emission using thermospray nebulization is studied at a fundamental level. Optimum signals and signal-to-noise ratios resul...
Sequential Speciation and Cascading Divergence
Sequential Speciation and Cascading Divergence
A central, long-standing, and largely untested premise in evolutionary ecology is that “biodiversity begets biodiversity” in a process referred to as “sequential” or “cascading” di...
Matrix Effects Studies with Fused-Silica Aperture Thermospray Sample Introduction to ICP-AES
Matrix Effects Studies with Fused-Silica Aperture Thermospray Sample Introduction to ICP-AES
Matrix effects with fused-silica aperture thermospray (FSApT) sample introduction for ICP-AES are found to be higher than those for pneumatic sample introduction. The effects are c...
An insight into the origin of elemental chromium in the lacquer of Qin terracotta warriors
An insight into the origin of elemental chromium in the lacquer of Qin terracotta warriors
Abstract The origin of elemental chromium for the archaeological weapons from the pits of Qin terracotta warriors in China has been highly controversial. Although previou...
Hexavalent Chromium Accumulation by Microscopic Fungi
Hexavalent Chromium Accumulation by Microscopic Fungi
Abstract The purpose of the study was to optimize the removal of Cr(VI) by means of the Trichoderma viride strain isolated from chromium mud samples a well as the Aspergillus n...
Valence Discrimination Effects with Thermospray Sample Introduction: Characterization and Prevention
Valence Discrimination Effects with Thermospray Sample Introduction: Characterization and Prevention
With thermospray sample introduction for atomic spectrometry, sensitivity for certain elements can be valence-dependent (valence discrimination effect). To this point, this effect ...
The Risk Implications of the Distribution of Chromium Forms in Environmental Media
The Risk Implications of the Distribution of Chromium Forms in Environmental Media
Chromium exhibits multiple oxidation (valence) states, ranging from (-II) to (+VI). Under natural conditions, however, chromium typically exists in the Cr(III) (trivalent) and/or C...
Removal of hexavalent chromium using polyphenol-based functional materials
Removal of hexavalent chromium using polyphenol-based functional materials
Chromium from industrial wastewater, waste, pesticides, fertilizers, etc., always causes serious environmental problems. High levels of chromium pollution can have adverse effects ...

Back to Top