Javascript must be enabled to continue!
Inhibiting sorbent stripping by designing a sorbent‐packed porous probe for headspace solid‐phase microextraction
View through CrossRef
To prevent the stripping of coating sorbents in headspace solid‐phase microextraction, a porous extraction probe with packed sorbent was introduced by using a porous stainless steel needle tube and homemade sol–gel sorbents. The traditional stainless‐steel needle tube was punched by a laser to obtain two rows of holes, which supply a passageway for analyte vapor during extraction and desorption. The sorbent was prepared by a traditional sol–gel method with both poly(ethylene glycol) and hydroxy‐terminated silicone oil as coating ingredients. Eight polycyclic aromatic hydrocarbons and six benzene series compounds were used as illustrative semi‐volatile and volatile organic compounds in sequence to verify the extraction performance of this porous headspace solid‐phase microextraction probe. It was found that the analysis method combining a headspace solid‐phase microextraction probe and gas chromatography with mass spectrometry yielded determination coefficients of no less than 0.985 and relative standard deviations of 4.3–12.4%. The porous headspace solid‐phase microextraction probe showed no decrease of extraction ability after 200 uses. These results demonstrate that the packed extraction probe with porous structure can be used for headspace solid‐phase microextraction. This novel design may overcome both the stripping and breakage problems of the conventional coating fiber.
Title: Inhibiting sorbent stripping by designing a sorbent‐packed porous probe for headspace solid‐phase microextraction
Description:
To prevent the stripping of coating sorbents in headspace solid‐phase microextraction, a porous extraction probe with packed sorbent was introduced by using a porous stainless steel needle tube and homemade sol–gel sorbents.
The traditional stainless‐steel needle tube was punched by a laser to obtain two rows of holes, which supply a passageway for analyte vapor during extraction and desorption.
The sorbent was prepared by a traditional sol–gel method with both poly(ethylene glycol) and hydroxy‐terminated silicone oil as coating ingredients.
Eight polycyclic aromatic hydrocarbons and six benzene series compounds were used as illustrative semi‐volatile and volatile organic compounds in sequence to verify the extraction performance of this porous headspace solid‐phase microextraction probe.
It was found that the analysis method combining a headspace solid‐phase microextraction probe and gas chromatography with mass spectrometry yielded determination coefficients of no less than 0.
985 and relative standard deviations of 4.
3–12.
4%.
The porous headspace solid‐phase microextraction probe showed no decrease of extraction ability after 200 uses.
These results demonstrate that the packed extraction probe with porous structure can be used for headspace solid‐phase microextraction.
This novel design may overcome both the stripping and breakage problems of the conventional coating fiber.
Related Results
PENJERAPAN GAS CO HASIL PEMBAKARAN SAMPAH MENGGUNAKAN SORBENT TERMODIFIKASI DALAM REAKTOR FIXED BED
PENJERAPAN GAS CO HASIL PEMBAKARAN SAMPAH MENGGUNAKAN SORBENT TERMODIFIKASI DALAM REAKTOR FIXED BED
ADSORPTION OF CO FROM WASTE COMBUSTION USING MODIFIED SORBENT IN A FIXED BED REACTOR. Gases produced by garbage burning consist of dangerous gases such as CO, SO2 and other gases. ...
Recent advances and trends in miniaturized sample preparation techniques
Recent advances and trends in miniaturized sample preparation techniques
AbstractAdvances in the area of sample preparation are significant and have been growing significantly in recent years. This initial step of the analysis is essential and must be c...
Sol–gel niobia sorbent with a positively charged octadecyl ligand providing enhanced enrichment of nucleotides and organophosphorus pesticides in capillary microextraction for online HPLC analysis
Sol–gel niobia sorbent with a positively charged octadecyl ligand providing enhanced enrichment of nucleotides and organophosphorus pesticides in capillary microextraction for online HPLC analysis
AbstractA niobia‐based sol–gel organic–inorganic hybrid sorbent carrying a positively charged C18 ligand (Nb2O5‐C18(+ve)) was synthesized to achieve enhanced enrichment capability ...
A New Mathematical Model for EOR Displacements Honouring Oil Ganglia
A New Mathematical Model for EOR Displacements Honouring Oil Ganglia
Abstract
During two-phase flow in porous media non-wetting phase is present simultaneously in states of mobile connected continuum and of trapped isolated ganglia...
Sorbent Membranes: Device Designs, Evaluations and Potential Applications
Sorbent Membranes: Device Designs, Evaluations and Potential Applications
ABSTRACTFor the biomedical application of sorbents in extracorporeal circulation, the system must be free of particle release and must be biocompatible. In addition, because of the...
Perilaku Beton Porous Dengan Penambahan Zat Aditif Superplastizer (Sika Viscocrete)
Perilaku Beton Porous Dengan Penambahan Zat Aditif Superplastizer (Sika Viscocrete)
ABSTRACT
According to ACI 522R-10, Larvious Concrete, or Pervious Concrete is defined as concrete that has a slump value almost close to zero, which is formed from Portland cement,...
To evaluate the outcome of varicose vein surgery with and without venous stripping
To evaluate the outcome of varicose vein surgery with and without venous stripping
Aim: The aim of this study to evaluate the outcome of varicose vein surgery with and without venous stripping.Material and methods: This research covered 100 varicose vein operatio...
Ionic liquid supported on an electrodeposited polycarbazole film for the headspace solid‐phase microextraction and gas chromatography determination of aromatic esters
Ionic liquid supported on an electrodeposited polycarbazole film for the headspace solid‐phase microextraction and gas chromatography determination of aromatic esters
A polycarbazole film was electrodeposited on a stainless‐steel wire from a solution of N,N‐dimethylformamide/propylene carbonate (1:9 v/v) containing 0.10 M carbazole and 0.10 M te...

