Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Two-dimensional sound pressure distribution: Visualization and calibration-free quantification via optical wave microphone CT scanning

View through CrossRef
In recent years, the optical wave microphone has emerged as an innovative technique, employing Fraunhofer diffraction of a laser beam, and shows promising applications in various acoustic domains where high electric and/or magnetic fields preclude the use of traditional microphones. This study utilized an optical wave microphone computed tomography (CT) scan and calibration-free quantification to ascertain sound pressure levels at multiple distances from the ultrasonic oscillator. The cornerstone of this study, which is different from the author’s previous studies, is the quantification of sound pressure distribution via a theoretical model that encompasses all physical parameters pertinent to the optical wave microphone’s experimental arrangement. This method has proven effective in visualizing and quantifying the two-dimensional sound pressure distribution emitted by an ultrasonic oscillator (40 kHz) without the necessity for calibration. The results demonstrate that the sound pressure distribution determined using the calibration-free optical wave microphone CT scan is in good agreement with the measurements obtained through a condenser microphone.
Title: Two-dimensional sound pressure distribution: Visualization and calibration-free quantification via optical wave microphone CT scanning
Description:
In recent years, the optical wave microphone has emerged as an innovative technique, employing Fraunhofer diffraction of a laser beam, and shows promising applications in various acoustic domains where high electric and/or magnetic fields preclude the use of traditional microphones.
This study utilized an optical wave microphone computed tomography (CT) scan and calibration-free quantification to ascertain sound pressure levels at multiple distances from the ultrasonic oscillator.
The cornerstone of this study, which is different from the author’s previous studies, is the quantification of sound pressure distribution via a theoretical model that encompasses all physical parameters pertinent to the optical wave microphone’s experimental arrangement.
This method has proven effective in visualizing and quantifying the two-dimensional sound pressure distribution emitted by an ultrasonic oscillator (40 kHz) without the necessity for calibration.
The results demonstrate that the sound pressure distribution determined using the calibration-free optical wave microphone CT scan is in good agreement with the measurements obtained through a condenser microphone.

Related Results

Under-Sampled Microphone Data as a Wind Measurement
Under-Sampled Microphone Data as a Wind Measurement
It is common human experience that wind is associated with noise. Acoustic noise is generated by the turbulent pressure fluctuations  associated with the shearing flow near the gro...
Characterization of Micromachined Seesaw Type Microphone
Characterization of Micromachined Seesaw Type Microphone
A seesaw type microphone is characterized to study its feasibility for sound source localization. The microphone is composed of a flexible rectangular diaphragm sustained by two to...
A catalogue of Martian sound
A catalogue of Martian sound
IntroductionThe two microphones onboard the Perseverance rover have now been operating for more than three years on the surface of Mars. They have provided the first sound recordin...
Hurricane Eloise Directional Wave Energy Spectra
Hurricane Eloise Directional Wave Energy Spectra
ABSTRACT Directiona1 wave energy spectra, calculated from data recorded during Hurricane Eloise (Gulf of Mexico, 1975), are presented. The spectra, based on an en...
Synchronized observation of pressure wave influence on plasma–target interaction using optical wave microphone and high-speed camera
Synchronized observation of pressure wave influence on plasma–target interaction using optical wave microphone and high-speed camera
Plasma–target interaction of atmospheric pressure plasma jet is one of the considerable things in a very wide range of biomedical applications with the transportation of reactive o...
Wave Force Calculations for Stokes and Non-Stokes Waves
Wave Force Calculations for Stokes and Non-Stokes Waves
ABSTRACT A new wave particle velocity procedure permits calculation of forces from regular wave profiles of more or less arbitrary wave crest to height ratios, as...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
Objectives To investigate the relationship between atrial fibrillation cardioversion and f wave in electrocardiogram, providing an ordinary and noninvasive method...

Back to Top