EPR/PTFE Dosimetry for Test Reactor Environments
View through CrossRef
In 1992 the Radiation Metrology Laboratory (RML) at Sandia National Laboratories implemented EPR/Alanine capabilities for use in routine and calibration activities at its Co-60 and pulsed-power facilities. At that time it also investigated the usefulness of the system for measurement of absorbed dose in the mixed neutron/photon environments of reactors such as the Sandia Pulsed Reactor and the Annular Core Research Reactor used for hardness testing of electronics. The RML concluded that the neutron response of alanine was a sufficiently high fraction of the overall dosimeter response that the resulting uncertainties in the photon dose would be unacceptably large for silicon-device testing. However, it also suggested that nonhydrogenous materials such as polytetrafluoroethylene (PTFE) would exhibit smaller neutron response and might be useful in mixed environments. Preliminary research with PTFE in photon environments indicated considerable promise, but further development was not pursued at that time. Because of renewed interest in absorbed dose measurements that could better define the individual contributions of photon and neutron components to the overall dose delivered to a test object, the RML has re-initiated the development of an EPR/PTFE dosimetry system. This paper presents a summary of the research, a description of the EPR/PTFE dosimetry system, and recommendations for preparation and fielding of the dosimetry in photon and mixed neutron/photon environments.
ASTM International100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959
Title: EPR/PTFE Dosimetry for Test Reactor Environments
Description:
In 1992 the Radiation Metrology Laboratory (RML) at Sandia National Laboratories implemented EPR/Alanine capabilities for use in routine and calibration activities at its Co-60 and pulsed-power facilities.
At that time it also investigated the usefulness of the system for measurement of absorbed dose in the mixed neutron/photon environments of reactors such as the Sandia Pulsed Reactor and the Annular Core Research Reactor used for hardness testing of electronics.
The RML concluded that the neutron response of alanine was a sufficiently high fraction of the overall dosimeter response that the resulting uncertainties in the photon dose would be unacceptably large for silicon-device testing.
However, it also suggested that nonhydrogenous materials such as polytetrafluoroethylene (PTFE) would exhibit smaller neutron response and might be useful in mixed environments.
Preliminary research with PTFE in photon environments indicated considerable promise, but further development was not pursued at that time.
Because of renewed interest in absorbed dose measurements that could better define the individual contributions of photon and neutron components to the overall dose delivered to a test object, the RML has re-initiated the development of an EPR/PTFE dosimetry system.
This paper presents a summary of the research, a description of the EPR/PTFE dosimetry system, and recommendations for preparation and fielding of the dosimetry in photon and mixed neutron/photon environments.
Related Results
Study on Glass Fabric Reinforced Polytetrafluoroethylene Composites Infused with Melted Cyanate Ester Resin
Study on Glass Fabric Reinforced Polytetrafluoroethylene Composites Infused with Melted Cyanate Ester Resin
Melted bisphenol A dicyanate ester (BADCy) resin was infused into glass fabric/ PTFE(GF/PTFE) wave-transparent composites to improve the mechanical properties of GF/PTFE composites...
Reactor Dosimetry and Nuclear Reactor Regulation
Reactor Dosimetry and Nuclear Reactor Regulation
An important function of reactor dosimetry is the verification of fluence values used in the calculation of pressure vessel embrittlement and its impact on (a) the fracture toughne...
Technologies for retrospective radiation dosimetry
Technologies for retrospective radiation dosimetry
Abstract
Radiation dosimetry is an important task for assessing the biological damages created in human being due to ionising radiation exposure. Ionising radiation ...
Microstructure and Tribological Properties of TPU/Fluoropolymer Composites
Microstructure and Tribological Properties of TPU/Fluoropolymer Composites
Abstract
A network of poly(tetrafluoroethylene) (PTFE) microfibers in a thermoplastic polyurethane (TPU) was prepared by melt mixing the TPU with solid PTFE particle...
Three Key Concerns for a Successful EPR Deployment and Usage
Three Key Concerns for a Successful EPR Deployment and Usage
The health care environment is unique because of the large and complex organisation with a traditional hierarchic structure that is governed by laws and regulations. This paper exa...
Polytetrafluoroethylene–N‐Vinylpyrrolidone graft copolymers: Affinity with plasma proteins
Polytetrafluoroethylene–N‐Vinylpyrrolidone graft copolymers: Affinity with plasma proteins
AbstractN‐vinylpyrrolidone was grafted onto films, grains, and tubes of polytetrafluoroethylene (PTFE) using a radiation procedure. By controlling the experimental conditions, it w...
Electron Paramagnetic Resonance Spectroscopy
Electron Paramagnetic Resonance Spectroscopy
AbstractElectron paramagnetic resonance (EPR) spectroscopy, also called electron spin resonance (ESR) or electron magnetic resonance (EMR), measures the absorption of electromagnet...
Developments in Reactor Dosimetry in Japan
Developments in Reactor Dosimetry in Japan
Recent activities in reactor dosimetry developments in Japan are reviewed. First, those of research, test and prototype reactors are shown. Next, the present status of surveillance...