Javascript must be enabled to continue!
Experimental Research On the Performance of a Novel Geo-Filament Anchor For An Earthen Architectural Site
View through CrossRef
Abstract
An efficient anchoring method, explicitly developed for small sliders, has hitherto been missing in the practice of earthen architecture conservation. Furthermore, anchoring performance studies conducted so far, have failed to fully take into account the soil characteristics of certain targets. To address these concerns, the conservation project conceived for the Gaochang Ruins, Turpan, in China, was selected as the testing ground to design a novel Geotechnical Filament Anchor (GFA) for reinforcing small sliders in the earthen historical ramparts. In-situ experiments were conducted for evaluating six parameters—anchoring length (L), GF thickness (H), bore diameter (D), grouting strength (S), GFA surface status (R), and inclination angle (A). These parameters were varied in order to determine the effect they produce on anchoring performance, as demonstrated by the indicators, including tensile strength, destruction mode, load displacement (P-S) relation, and strain (ζ-L) distribution characteristics of the novel GFA. Data acquired from the experiments, in combination with the conservation specifics of earthen architectural sites, anchoring performance, and safety reserve, were further employed to introduce a calculation formula for computing the designed force value (N) through L. A simplified model depicting the shear stress distribution of the anchoring system under N was devised by extracting the strain distribution data with respect to the GF-grouting interface. Taking into account the soil properties of the above-mentioned site, the shear stress diffusion coefficient (α) was conceptualized, the formula for the shear strength of the grouting material was devised, and the tolerable ranges of L, D, H, R, and S were determined. Thus, a feasible anchoring method for small sliders used in earthen architectural sites is proposed, and validated by strong and reliable experimental and theoretical groundwork.
Title: Experimental Research On the Performance of a Novel Geo-Filament Anchor For An Earthen Architectural Site
Description:
Abstract
An efficient anchoring method, explicitly developed for small sliders, has hitherto been missing in the practice of earthen architecture conservation.
Furthermore, anchoring performance studies conducted so far, have failed to fully take into account the soil characteristics of certain targets.
To address these concerns, the conservation project conceived for the Gaochang Ruins, Turpan, in China, was selected as the testing ground to design a novel Geotechnical Filament Anchor (GFA) for reinforcing small sliders in the earthen historical ramparts.
In-situ experiments were conducted for evaluating six parameters—anchoring length (L), GF thickness (H), bore diameter (D), grouting strength (S), GFA surface status (R), and inclination angle (A).
These parameters were varied in order to determine the effect they produce on anchoring performance, as demonstrated by the indicators, including tensile strength, destruction mode, load displacement (P-S) relation, and strain (ζ-L) distribution characteristics of the novel GFA.
Data acquired from the experiments, in combination with the conservation specifics of earthen architectural sites, anchoring performance, and safety reserve, were further employed to introduce a calculation formula for computing the designed force value (N) through L.
A simplified model depicting the shear stress distribution of the anchoring system under N was devised by extracting the strain distribution data with respect to the GF-grouting interface.
Taking into account the soil properties of the above-mentioned site, the shear stress diffusion coefficient (α) was conceptualized, the formula for the shear strength of the grouting material was devised, and the tolerable ranges of L, D, H, R, and S were determined.
Thus, a feasible anchoring method for small sliders used in earthen architectural sites is proposed, and validated by strong and reliable experimental and theoretical groundwork.
Related Results
Monogenean anchor morphometry: systematic value, phylogenetic signal, and evolution
Monogenean anchor morphometry: systematic value, phylogenetic signal, and evolution
Background.Anchors are one of the important attachment appendages for monogenean parasites. Common descent and evolutionary processes have left their mark on anchor morphometry, in...
Experimental Research on the Performance of a Novel Geo- filament Anchor for an Earthen Architectural Site
Experimental Research on the Performance of a Novel Geo- filament Anchor for an Earthen Architectural Site
Abstract
An efficient anchoring method, explicitly developed for small sliders, has hitherto been missing in the practice of earthen architecture conservation. Furthermore,...
Experimental Research on the Performance of a Novel Geo- filament Anchor for an Earthen Architectural Site
Experimental Research on the Performance of a Novel Geo- filament Anchor for an Earthen Architectural Site
Abstract
An efficient anchoring method, explicitly developed for small sliders, has hitherto been missing in the practice of earthen architecture conservation. Furthermore,...
Earthen Architecture in Southern Algeria: An Assessment of Social Values and the Impact of Industrial Building Practices
Earthen Architecture in Southern Algeria: An Assessment of Social Values and the Impact of Industrial Building Practices
Abstract
Earthen architecture constitutes a significant component of cultural heritage worldwide. However, this heritage is under threat due to a multitude of factor...
Tamaki Ura and Yoshiyuki Yamamoto, University of Tokyo
Tamaki Ura and Yoshiyuki Yamamoto, University of Tokyo
Abstract
Since soil-loading on an anchor embedded has not been clarified, modern mooring anchors have been obliged to be designed on the basis of previous experie...
The Observatory
The Observatory
<p><b>This thesis investigation looks at how transformative heritage stories linked to abandoned architectural sites can be reawakened through an allegorical architectu...
Interpositional Bioresorbable Scaffold-Anchor Appears Non-inferior to a Standard Anchor in the Treatment of Rotator Cuff Tears
Interpositional Bioresorbable Scaffold-Anchor Appears Non-inferior to a Standard Anchor in the Treatment of Rotator Cuff Tears
Background
Failure after rotator cuff repair is typically due to a loss of integrity of the bone-tendon interface. The BioWick anchor (Zimmer-Biomet) is an interpositio...
Monogenean anchor morphometry: systematic value, phylogenetic signal, and evolution
Monogenean anchor morphometry: systematic value, phylogenetic signal, and evolution
Anchors are important attachment appendages that prevent the physical dislodging of a monogenean parasite from fish host gills. Common descent and evolutionary processes have left ...

