Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Histological Processing of CAD/CAM Titanium Scaffold after Long-Term Failure in Cranioplasty

View through CrossRef
Cranioplasty is a frequently performed procedure after craniectomy and includes several techniques with different materials. Due to high overall complication rates, alloplastic implants are removed in many cases. Lack of implant material osseointegration is often assumed as a reason for failure, but no study has proven this in cranioplasty. This study histologically evaluates the osteointegration of a computer-aided design and computer-aided manufacturing (CAD/CAM) titanium scaffold with an open mesh structure used for cranioplasty. A CAD/CAM titanium scaffold was removed due to late soft tissue complications 7.6 years after cranioplasty. The histological analyses involved the preparation of non-decalcified slices from the scaffold’s inner and outer sides as well as a light-microscopic evaluation, including the quantification of the bone that had formed over the years. Within the scaffold pores, vital connective tissue with both blood vessels and nerves was found. Exclusive bone formation only occurred at the edges of the implant, covering 0.21% of the skin-facing outer surface area. The inner scaffold surface, facing towards the brain, did not show any mineralization at all. Although conventional alloplastic materials for cranioplasty reduce surgery time and provide good esthetic results while mechanically protecting the underlying structures, a lack of adequate stimuli could explain the limited bone formation found. CAD/CAM porous titanium scaffolds alone insufficiently osseointegrate in such large bone defects of the skull. Future research should investigate alternative routes that enable long-term osteointegration in order to reduce complication rates after cranioplasty. Opportunities could be found in mechano-biologically optimized scaffolds, material modifications, surface coatings, or other routes to sustain bone formation.
Title: Histological Processing of CAD/CAM Titanium Scaffold after Long-Term Failure in Cranioplasty
Description:
Cranioplasty is a frequently performed procedure after craniectomy and includes several techniques with different materials.
Due to high overall complication rates, alloplastic implants are removed in many cases.
Lack of implant material osseointegration is often assumed as a reason for failure, but no study has proven this in cranioplasty.
This study histologically evaluates the osteointegration of a computer-aided design and computer-aided manufacturing (CAD/CAM) titanium scaffold with an open mesh structure used for cranioplasty.
A CAD/CAM titanium scaffold was removed due to late soft tissue complications 7.
6 years after cranioplasty.
The histological analyses involved the preparation of non-decalcified slices from the scaffold’s inner and outer sides as well as a light-microscopic evaluation, including the quantification of the bone that had formed over the years.
Within the scaffold pores, vital connective tissue with both blood vessels and nerves was found.
Exclusive bone formation only occurred at the edges of the implant, covering 0.
21% of the skin-facing outer surface area.
The inner scaffold surface, facing towards the brain, did not show any mineralization at all.
Although conventional alloplastic materials for cranioplasty reduce surgery time and provide good esthetic results while mechanically protecting the underlying structures, a lack of adequate stimuli could explain the limited bone formation found.
CAD/CAM porous titanium scaffolds alone insufficiently osseointegrate in such large bone defects of the skull.
Future research should investigate alternative routes that enable long-term osteointegration in order to reduce complication rates after cranioplasty.
Opportunities could be found in mechano-biologically optimized scaffolds, material modifications, surface coatings, or other routes to sustain bone formation.

Related Results

Comparative Cost-Effectiveness of Cranioplasty Implants
Comparative Cost-Effectiveness of Cranioplasty Implants
Purpose: The aim of this study was to compare operative duration and total hospital costs incurred for patients undergoing elective cranioplasty with a variety of materials, includ...
Cranioplasty in Acoustic Neuroma Surgery
Cranioplasty in Acoustic Neuroma Surgery
AbstractObjectives To measure the incidence of postoperative headaches after retrosigmoid resections of acoustic neuromas and to evaluate the impact of cranioplasty on the preventi...
Synthesis and Investigation into Apatite-forming Ability of Hydroxyapatite/Chitosan-based Scaffold
Synthesis and Investigation into Apatite-forming Ability of Hydroxyapatite/Chitosan-based Scaffold
In this study, porous scaffolds were fabricated using inorganic material-hydroxyapatite and chitosan for bone-tissue engineering. The combination of hydroxyapatite and chitosan may...
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cement...
Effects of Veneering Ceramic and Methods on Failure Load of Veneered Zirconia
Effects of Veneering Ceramic and Methods on Failure Load of Veneered Zirconia
Background: A variety of veneering options to zirconia frameworks are now available. The purpose of this study is to evaluate the effect of veneer materials, veneering methods, cem...

Back to Top