Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of LC-MS/MS and Enzymatic Methods for the Determination of Total Choline and Total Carnitine in Infant Formula and Milk Products

View through CrossRef
Abstract Background Choline and l-carnitine are classified as pseudo-vitamins because of their conditionally essential status. As they are involved in multiple physiological metabolic pathways in the human body, they are routinely fortified in infant and adult nutritional formulas. Objective The performance of an LC-MS/MS method for the analysis of choline and carnitine, compared with enzymatic methods in routine use for the analysis of total carnitine and total choline, is described. Method Powder samples were reconstituted, with release of carnitine and choline facilitated by both acid and alkaline hydrolysis and the extract analyzed by LC-MS/MS. Quantitation was by internal standard technique using deuterium-labeled carnitine and deuterium-labeled choline. Results Method range, specificity, sensitivity, precision, recovery, accuracy, and ruggedness were assessed for milk powders, infant formulas, and soy- and milk-based nutritional products. Spike recoveries of 94.0–108.4% were obtained for both total carnitine and choline, and no statistical bias (α = 0.05) between measured results and certified values (choline: P = 0.36; free carnitine: P = 0.67) was found for NIST 1849a certified reference material (NIST1849a). Precision, as repeatability relative standard deviation (RSD), was 2.0% RSDr for total carnitine and 1.7% RSDr for total choline. Equivalent results for total choline and total carnitine were obtained by LC-MS/MS and enzymatic methods (n = 30). Conclusions The described LC-MS/MS method is fit for purpose for routine product compliance release testing environments. This validation study has confirmed that alternative enzymatic assays can be used with confidence in laboratories in which LC-MS/MS platforms are unavailable. Highlights An LC-MS/MS method was evaluated and found to be fit-for-purpose for routine product compliance release testing of infant formula. The LC-MS/MS method was compared with enzymatic methods for the analysis of total carnitine and total choline. Alternative enzymatic assays can be used with confidence in laboratories in which LC-MS/MS platforms are unavailable.
Title: Comparison of LC-MS/MS and Enzymatic Methods for the Determination of Total Choline and Total Carnitine in Infant Formula and Milk Products
Description:
Abstract Background Choline and l-carnitine are classified as pseudo-vitamins because of their conditionally essential status.
As they are involved in multiple physiological metabolic pathways in the human body, they are routinely fortified in infant and adult nutritional formulas.
Objective The performance of an LC-MS/MS method for the analysis of choline and carnitine, compared with enzymatic methods in routine use for the analysis of total carnitine and total choline, is described.
Method Powder samples were reconstituted, with release of carnitine and choline facilitated by both acid and alkaline hydrolysis and the extract analyzed by LC-MS/MS.
Quantitation was by internal standard technique using deuterium-labeled carnitine and deuterium-labeled choline.
Results Method range, specificity, sensitivity, precision, recovery, accuracy, and ruggedness were assessed for milk powders, infant formulas, and soy- and milk-based nutritional products.
Spike recoveries of 94.
0–108.
4% were obtained for both total carnitine and choline, and no statistical bias (α = 0.
05) between measured results and certified values (choline: P = 0.
36; free carnitine: P = 0.
67) was found for NIST 1849a certified reference material (NIST1849a).
Precision, as repeatability relative standard deviation (RSD), was 2.
0% RSDr for total carnitine and 1.
7% RSDr for total choline.
Equivalent results for total choline and total carnitine were obtained by LC-MS/MS and enzymatic methods (n = 30).
Conclusions The described LC-MS/MS method is fit for purpose for routine product compliance release testing environments.
This validation study has confirmed that alternative enzymatic assays can be used with confidence in laboratories in which LC-MS/MS platforms are unavailable.
Highlights An LC-MS/MS method was evaluated and found to be fit-for-purpose for routine product compliance release testing of infant formula.
The LC-MS/MS method was compared with enzymatic methods for the analysis of total carnitine and total choline.
Alternative enzymatic assays can be used with confidence in laboratories in which LC-MS/MS platforms are unavailable.

Related Results

A2 milk: a new way to offer a flat white?
A2 milk: a new way to offer a flat white?
This research sought feedback from professional baristas on their views and experiences of A2 milk use in café coffee production. Their views are important because Aotearoa New Zea...
Carnitine Inborn Errors of Metabolism
Carnitine Inborn Errors of Metabolism
Carnitine plays essential roles in intermediary metabolism. In non-vegetarians, most of carnitine sources (~75%) are obtained from diet whereas endogenous synthesis accounts for ar...
Formula Tolerance in Postbreastfed and Exclusively Formula-fed Infants
Formula Tolerance in Postbreastfed and Exclusively Formula-fed Infants
Objective.  Perceived intolerance to infant formula is a frequently reported reason for formula switching. Formula intolerance may be related to perceived symptom...
Choline and Betaine Levels in Plasma Mirror Choline Intake in Very Preterm Infants
Choline and Betaine Levels in Plasma Mirror Choline Intake in Very Preterm Infants
Choline is essential for cell membrane formation and methyl transfer reactions, impacting parenchymal and neurological development. It is therefore enriched via placental transfer,...
Role of carnitine in regulation of hypoglycemia-induced hypertension and cardiac hypertrophy
Role of carnitine in regulation of hypoglycemia-induced hypertension and cardiac hypertrophy
Abstract Background: Cardiovascular disease is a leading cause of death in diabetic patients. Hyperglycemia and iatrogenic hypoglycemia exacerbate several pathogenic mechan...
British Food Journal Volume 45 Issue 6 1943
British Food Journal Volume 45 Issue 6 1943
In 1934 the Milk Marketing Board came into being, and with it the “Milk in Schools Scheme.” and all its promises to provide millions of school children with milk “approved” by Coun...
Choline in Pediatric Nutrition: Assessing Formula, Fortifiers and Supplements Across Age Groups and Clinical Indications
Choline in Pediatric Nutrition: Assessing Formula, Fortifiers and Supplements Across Age Groups and Clinical Indications
Background: Sufficient choline supply is essential for tissue functions via phosphatidylcholine and sphingomyelin within membranes and secretions like bile, lipoproteins and surfac...
Theoretical study of laser-cooled SH<sup>–</sup> anion
Theoretical study of laser-cooled SH<sup>–</sup> anion
The potential energy curves, dipole moments, and transition dipole moments for the <inline-formula><tex-math id="M13">\begin{document}${{\rm{X}}^1}{\Sigma ^ + }$\end{do...

Back to Top