Convergent Validity of 3 Low Cost Motion Sensors With the ActiGraph Accelerometer
View through CrossRef
Background:This study evaluated the utility of several lower cost physical activity (PA) assessment instruments for detecting PA volume (steps) and intensity (time in MVPA or activity time) using convergent methods of assessment.Methods:Participants included 26 adults (9 male) age 27.3 ± 7.1 years with a BMI of 23.8 ± 2.8 kg/m2. Instruments evaluated included the Omron HJ-151 (OM), New Lifestyles NL-1000 (NL), Walk4Life W4L Pro (W4L), and ActiGraph GT1M (AG). Participants wore all instruments during a laboratory phase, consisting of 10 single minute treadmill walking bouts ranging in speed from 40 to 112 m/min, and immediate following the laboratory phase and during the remainder of their free-living day (11.3 ± 1.5 hours). Previously validated AG MVPA cutpoints were used for comparison with OM, NL, and W4L MVPA or activity time outputs during the laboratory and free-living phase.Results:OM and NL produced similar MVPA estimates during free-living to commonly used AG walking cutpoints, and W4L activity time estimates were similar to one AG lifestyle cutpoint evaluated.Conclusion:Current findings indicate that the OM, NL, and W4L, ranging in price from $15 to $49, can provide reasonable estimates of free-living MVPA or activity time in comparison with a range of AG walking and lifestyle cutpoints.
Title: Convergent Validity of 3 Low Cost Motion Sensors With the ActiGraph Accelerometer
Description:
Background:This study evaluated the utility of several lower cost physical activity (PA) assessment instruments for detecting PA volume (steps) and intensity (time in MVPA or activity time) using convergent methods of assessment.
Methods:Participants included 26 adults (9 male) age 27.
3 ± 7.
1 years with a BMI of 23.
8 ± 2.
8 kg/m2.
Instruments evaluated included the Omron HJ-151 (OM), New Lifestyles NL-1000 (NL), Walk4Life W4L Pro (W4L), and ActiGraph GT1M (AG).
Participants wore all instruments during a laboratory phase, consisting of 10 single minute treadmill walking bouts ranging in speed from 40 to 112 m/min, and immediate following the laboratory phase and during the remainder of their free-living day (11.
3 ± 1.
5 hours).
Previously validated AG MVPA cutpoints were used for comparison with OM, NL, and W4L MVPA or activity time outputs during the laboratory and free-living phase.
Results:OM and NL produced similar MVPA estimates during free-living to commonly used AG walking cutpoints, and W4L activity time estimates were similar to one AG lifestyle cutpoint evaluated.
Conclusion:Current findings indicate that the OM, NL, and W4L, ranging in price from $15 to $49, can provide reasonable estimates of free-living MVPA or activity time in comparison with a range of AG walking and lifestyle cutpoints.
Related Results
Development of low-cost sensors for structural health monitoring applications
Development of low-cost sensors for structural health monitoring applications
(English) There is increasing interest in developing low-cost sensors for economical structural health monitoring of civil engineering infrastructures. In addition to their price, ...
Convergent transcriptomic and genomic adaptation in xeric rodents
Convergent transcriptomic and genomic adaptation in xeric rodents
ABSTRACTRepeated adaptations rely in part on convergent genetic changes. The extent of convergent changes at the genomic scale is debated and may depend on the interplay between di...
Validity of the Walked Distance Estimated by Wearable Devices in Stroke Individuals
Validity of the Walked Distance Estimated by Wearable Devices in Stroke Individuals
Background: Health professionals need valid devices to assess a stroke individual’s ability to walk. The aim was to evaluate the validity of the estimation of the walked distance b...
Nafion Based Two Electrode CO Sensor
Nafion Based Two Electrode CO Sensor
The aim of this work is to determine the optimal platinum loading for the preparation of membrane-based electrochemical sensors for carbon monoxide detection. Platinum is a require...
ONERA accelerometers for future gravity mission
ONERA accelerometers for future gravity mission
The 2017-2027 Decadal Survey for Earth Science and Applications from Space has identified the Targeted Mass Change Observable as one of 5 Designated Mission. In Europe, ESA has pro...
ONERA accelerometers for future gravity mission
ONERA accelerometers for future gravity mission
The 2017-2027 Decadal Survey for Earth Science and Applications from Space has identified the Targeted Mass Change Observable as one of 5 Designated Mission. In Europe, ESA has con...
All-Fabric Piezoionic Sensor for Simultaneous Sensing of Static and Dynamic Pressures
All-Fabric Piezoionic Sensor for Simultaneous Sensing of Static and Dynamic Pressures
The development of flexible and textile-based wearable pressure sensors has provided the opportunity of continuous and real time measurement of human physiological and biomechanica...
A self-centering and stiffness-controlled MEMS accelerometer
A self-centering and stiffness-controlled MEMS accelerometer
AbstractThis paper presents a high-performance MEMS accelerometer with a DC/AC electrostatic stiffness tuning capability based on double-sided parallel plates (DSPPs). DC and AC el...