Javascript must be enabled to continue!
The Influence of Temperature on Errors of Wim Systems Employing Piezoelectric Sensors Keywords: Piezoelectric Sensors, Temperature Influence, Temperature Error Of Wim Systems, Error Correction
View through CrossRef
Abstract
The paper provides analysis of the influence of temperature on the error of weigh-in-motion (WIM) systems utilizing piezoelectric polymer load sensors. Results of tests of these sensors in a climatic chamber, as well as results of long-term tests at the WIM site, are presented. Different methods for correction of the influence of changes in temperature were assessed for their effectiveness and compared.
Polish Academy of Sciences Chancellery
Title: The Influence of Temperature on Errors of Wim Systems Employing Piezoelectric Sensors Keywords: Piezoelectric Sensors, Temperature Influence, Temperature Error Of Wim Systems, Error Correction
Description:
Abstract
The paper provides analysis of the influence of temperature on the error of weigh-in-motion (WIM) systems utilizing piezoelectric polymer load sensors.
Results of tests of these sensors in a climatic chamber, as well as results of long-term tests at the WIM site, are presented.
Different methods for correction of the influence of changes in temperature were assessed for their effectiveness and compared.
Related Results
Review of high temperature piezoelectric materials, devices, and applications
Review of high temperature piezoelectric materials, devices, and applications
Piezoelectric functional materials have been extensively studied and employed in numerous devices. With the rapid development of modern industries, such as power plants, aerospace,...
Design, fabrication, and properties of 2-2 connectivity cement/polymer based piezoelectric composites with varied piezoelectric phase distribution
Design, fabrication, and properties of 2-2 connectivity cement/polymer based piezoelectric composites with varied piezoelectric phase distribution
The laminated 2-2 connectivity cement/polymer based piezoelectric composites with varied piezoelectric phase distribution were fabricated by employing Lead Zirconium Titanate ceram...
SMART TEMPERATURE SENSORS FOR TEMPERATURE CONTROL SYSTEMS
SMART TEMPERATURE SENSORS FOR TEMPERATURE CONTROL SYSTEMS
Temperature control systems are pivotal in various applications, ranging from industrial processes and environmental monitoring to everyday comfort and safety. Smart temperature se...
Future Prospects of Piezoelectric Perovskite Materials
Future Prospects of Piezoelectric Perovskite Materials
Piezoelectric perovskite materials have emerged as a promising class of
materials due to their unique combination of piezoelectric properties, mechanical
stability, and wide bandga...
A Comparative Study of Two Temperature Interpolation Methods: A Case Study of the Middle East of Qilian Mountain
A Comparative Study of Two Temperature Interpolation Methods: A Case Study of the Middle East of Qilian Mountain
Abstract
Background, aim, and scope The Middle East section of Qilian Mountain was used as the study area, and the temperature interpolation method based on DEM was ...
Detection of Subtle Sensor Errors in Mineral Processing Circuits Using Data-Mining Techniques
Detection of Subtle Sensor Errors in Mineral Processing Circuits Using Data-Mining Techniques
AbstractThe economics of a mineral processing circuit is dependent on the numerous sensors that are critical to optimization and control systems. The sheer volume of sensors result...
Deep Learning Phase Error Correction for Cerebrovascular 4D Flow MRI
Deep Learning Phase Error Correction for Cerebrovascular 4D Flow MRI
Abstract
Background and Purpose
Background phase errors in 4D Flow MRI may negatively impact blood flow quantification. In this study, we assessed their impact on cerebrov...
Piezoelectric Actuators – Recent Innovations 2024 –
Piezoelectric Actuators – Recent Innovations 2024 –
This article reviews recent innovations in piezoelectric actuators, then indicates the future research targets. In the materials, the piezoelectric performances of relaxor-lead tit...