Hammering Force during Cementless Total Hip Arthroplasty and Risk of Microfracture
View through CrossRef
During cementless stem fixation, impaction of the stem is occasionally complicated by bony injuries. Small fractures not visible to the eye during surgery or on post-operative radiographs may remain undetected, and the incidence of such injuries may be underestimated. Employing the same techniques as those employed during total hip arthroplasty, we implanted cementless stems into artificial femora, with equivalent mechanical characteristics to living femora. The hammering force applied to the femur and the displacement of the stem and femur were measured using a load sensor and imaging, respectively. The von Mises stress generated in the femur during cementless stem press-fixation was also measured using finite element analysis. Average hammering force under these conditions (9.25 kN) was sufficient to cause damage to the artificial femur. The first two of eight hammer strikes caused most displacement of the stem. The von Mises stresses generated by the first and second hammer strikes were 31 and 68 MPa, respectively. Applying a high average hammering force to the stem after displacement has ceased probably contributes to the generation of intraoperative fractures during cementless stem fixation. Given that two strikes appeared to be sufficient, we believe that hammering force should be reduced to a micro-adjustment level after the second hit.
Title: Hammering Force during Cementless Total Hip Arthroplasty and Risk of Microfracture
Description:
During cementless stem fixation, impaction of the stem is occasionally complicated by bony injuries.
Small fractures not visible to the eye during surgery or on post-operative radiographs may remain undetected, and the incidence of such injuries may be underestimated.
Employing the same techniques as those employed during total hip arthroplasty, we implanted cementless stems into artificial femora, with equivalent mechanical characteristics to living femora.
The hammering force applied to the femur and the displacement of the stem and femur were measured using a load sensor and imaging, respectively.
The von Mises stress generated in the femur during cementless stem press-fixation was also measured using finite element analysis.
Average hammering force under these conditions (9.
25 kN) was sufficient to cause damage to the artificial femur.
The first two of eight hammer strikes caused most displacement of the stem.
The von Mises stresses generated by the first and second hammer strikes were 31 and 68 MPa, respectively.
Applying a high average hammering force to the stem after displacement has ceased probably contributes to the generation of intraoperative fractures during cementless stem fixation.
Given that two strikes appeared to be sufficient, we believe that hammering force should be reduced to a micro-adjustment level after the second hit.
Related Results
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fragility, with a 22% one...
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
AIM: To investigate the risk factors of perioperative transfusion in hip arthroplasty and to construct a nomogram model to predict the risk of transfusion. METHODS: A total of 120 ...
Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty
Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty
AbstractAn adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musc...
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
AbstractObjectiveTo describe disability in individuals with hip arthroplasty and its evolution over 2 years compared with that in the general population, and to compare the degree ...
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Aims Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic looseni...
Do Stem Design and Surgical Approach Influence Early Aseptic Loosening in Cementless THA?
Do Stem Design and Surgical Approach Influence Early Aseptic Loosening in Cementless THA?
Abstract
Background
Some studies have revealed an increased risk of early aseptic loosening of cementless stems in THA when inserted through an a...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract
Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...