Javascript must be enabled to continue!
serpent 2 Validation for Radiation Shielding Applications
View through CrossRef
Abstract
This paper contributes to the validation of serpent's photon transport and coupled neutron–photon transport routines. Two benchmarks presenting measurements of neutron and photon flux through different sized iron and lead spheres have been calculated using a development version of serpent and mcnp6.2. The serpent results were compared to the measurement results and the mcnp6.2 calculations. Additionally, the development version has been compared to the currently distributed serpent version 2.1.31. In all cases, the serpent calculated neutron and photon spectra followed the measured spectra fairly well. For the iron spheres, differences between serpent and mcnp6.2 calculated neutron spectra were mostly below 2% at neutron energies below 4 MeV. Differences between photon spectra through the iron spheres were mostly below 3%. For the lead spheres, differences in the calculated neutron spectra were mostly below 1.5% in the energy range 0.04–4.0 MeV. Differences between photon spectra through the 10 cm lead sphere were mostly below 5% and for the larger spheres below 10% except at higher photon energies above 6.5 MeV. Differences between the development version and the serpent version 2.1.31 of the order of 3% were observed in the photon spectra through the largest lead spheres with radius 20 and 30 cm when Gaussian Energy Broadening was not applied. These are probably related to the coupled neutron-photon transport routines in the different versions.
Title: serpent 2 Validation for Radiation Shielding Applications
Description:
Abstract
This paper contributes to the validation of serpent's photon transport and coupled neutron–photon transport routines.
Two benchmarks presenting measurements of neutron and photon flux through different sized iron and lead spheres have been calculated using a development version of serpent and mcnp6.
2.
The serpent results were compared to the measurement results and the mcnp6.
2 calculations.
Additionally, the development version has been compared to the currently distributed serpent version 2.
1.
31.
In all cases, the serpent calculated neutron and photon spectra followed the measured spectra fairly well.
For the iron spheres, differences between serpent and mcnp6.
2 calculated neutron spectra were mostly below 2% at neutron energies below 4 MeV.
Differences between photon spectra through the iron spheres were mostly below 3%.
For the lead spheres, differences in the calculated neutron spectra were mostly below 1.
5% in the energy range 0.
04–4.
0 MeV.
Differences between photon spectra through the 10 cm lead sphere were mostly below 5% and for the larger spheres below 10% except at higher photon energies above 6.
5 MeV.
Differences between the development version and the serpent version 2.
1.
31 of the order of 3% were observed in the photon spectra through the largest lead spheres with radius 20 and 30 cm when Gaussian Energy Broadening was not applied.
These are probably related to the coupled neutron-photon transport routines in the different versions.
Related Results
WE‐B‐330A‐01: Shielding Design Workshop: PET/CT
WE‐B‐330A‐01: Shielding Design Workshop: PET/CT
The application of the structural shielding design techniques and goals as outlined in AAPM Task Group Report 108: PET and PET/CT Shielding Requirements Medical Physics (Vol. 33., ...
Validation in Doctoral Education: Exploring PhD Students’ Perceptions of Belonging to Scaffold Doctoral Identity Work
Validation in Doctoral Education: Exploring PhD Students’ Perceptions of Belonging to Scaffold Doctoral Identity Work
Aim/Purpose: The aim of this article is to make a case of the role of validation in doctoral education. The purpose is to detail findings from three studies which explore PhD stude...
Enhancing Gamma-Neutron Shielding Effectiveness of Polyvinylidene Fluoride for Potent Applications in Nuclear Industries: A Study on the Impact of Tungsten Carbide, Trioxide, and Disulfide Using EpiXS, Phy-X/PSD, and MCNP5 Code
Enhancing Gamma-Neutron Shielding Effectiveness of Polyvinylidene Fluoride for Potent Applications in Nuclear Industries: A Study on the Impact of Tungsten Carbide, Trioxide, and Disulfide Using EpiXS, Phy-X/PSD, and MCNP5 Code
Background: Radiation protection is crucial in various fields due to the harmful effects of radiation. Shielding is used to reduce radiation exposure, but gamma radiation poses cha...
Boron and Boron Compounds in Radiation Shielding Materials
Boron and Boron Compounds in Radiation Shielding Materials
A risk to the nuclear industry is radiation, specifically neutron radiation. In order to maintain a safe workspace for workers, better shielding is being developed. Current shieldi...
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Cathlab radiation workers, when performing interventional procedures, are at high risk of the effects of radiation exposure. The risk of radiation exposure is deterministic and sto...
CO
2
, Fiber, and
UV
Direct Laser Writing of Graphene for Flexible
EMI
Shielding Applications: A Comparative Stu
CO
2
, Fiber, and
UV
Direct Laser Writing of Graphene for Flexible
EMI
Shielding Applications: A Comparative Stu
ABSTRACT
As electronic devices become an inseparable part of modern life, the challenge of electromagnetic interference (EMI) continues to gr...
Deuterium tritium fusion experiment device radiation shielding analysis and optimization
Deuterium tritium fusion experiment device radiation shielding analysis and optimization
As deuterium-tritium (D-T) fusion experiments progress, radiation shielding is a fundamental requirement for ensuring personnel safety of fusion devices. This study utilizes neutro...
SU‐FF‐I‐43: Workload Weighed Transmission Curves of Brazilian Shielding Materials: Experimental Results
SU‐FF‐I‐43: Workload Weighed Transmission Curves of Brazilian Shielding Materials: Experimental Results
Purpose: Evaluation of attenuation properties of typical Brazilian shielding materials (Barite Concrete) used in diagnostic rooms from transmission measurements considering the loc...