Precision of Optic Nerve Head and Retinal Nerve Fiber Layer Parameter Measurements by Spectral-domain Optical Coherence Tomography

View through CrossRef
Purpose: The aim of this study was to assess the repeatability and reproducibility (R&R) of Bruch membrane opening based on minimum rim width (BMO-MRW), minimum rim area (BMO-MRA) and peripapillary retinal nerve fiber layer thickness (RNFLT) with the Spectralis optical coherence tomography (Heidelberg Engineering) for normal and glaucoma subjects. Precise measurement of these parameters can support detection of structural glaucomatous damage and progression. Methods: This cross-sectional study included 16 healthy controls and 16 patients with glaucoma. One eye was randomly selected and included in this study. Subjects underwent 1 baseline and 3 follow-up measurements, using 3 different Spectralis optical coherence tomography devices in randomized order, each operated by a single operator. Outcome measures were global and sectorial averages of BMO-MRW and BMO-MRA, and of peripapillary RNFLT obtained from 12/14/16-degree circle scans. Coefficients of variation (COV) were calculated and a mixed-effects analysis of variance was performed to compare R&R between devices. Results: COVs of global and sectorial BMO-MRW measurement under repeatability conditions ranged from 0.51% to 1.7% (normal, 0.62% to 1.3%; glaucoma, 0.64% to 2.3%). Respective COVs under reproducibility conditions ranged from 0.89% to 1.9% (normal, 0.77% to 2.8%; glaucoma, 1.1% to 2.6%). COVs of global and sectorial RNFLT measurements under repeatability conditions ranged from 0.5% to 2.8%. Respective COVs under reproducibility conditions ranged from 1.6% to 3.5%. Conclusions: For R&R, the COVs of measured parameters were by trend higher for glaucoma eyes compared with normal controls. The BMO-MRW measurement system has an excellent precision taking into account that major and minor corrections of segmentation have to be done by the examiner before evaluation.
Title: Precision of Optic Nerve Head and Retinal Nerve Fiber Layer Parameter Measurements by Spectral-domain Optical Coherence Tomography
Description:
Purpose: The aim of this study was to assess the repeatability and reproducibility (R&R) of Bruch membrane opening based on minimum rim width (BMO-MRW), minimum rim area (BMO-MRA) and peripapillary retinal nerve fiber layer thickness (RNFLT) with the Spectralis optical coherence tomography (Heidelberg Engineering) for normal and glaucoma subjects.
Precise measurement of these parameters can support detection of structural glaucomatous damage and progression.
Methods: This cross-sectional study included 16 healthy controls and 16 patients with glaucoma.
One eye was randomly selected and included in this study.
Subjects underwent 1 baseline and 3 follow-up measurements, using 3 different Spectralis optical coherence tomography devices in randomized order, each operated by a single operator.
Outcome measures were global and sectorial averages of BMO-MRW and BMO-MRA, and of peripapillary RNFLT obtained from 12/14/16-degree circle scans.
Coefficients of variation (COV) were calculated and a mixed-effects analysis of variance was performed to compare R&R between devices.
Results: COVs of global and sectorial BMO-MRW measurement under repeatability conditions ranged from 0.
51% to 1.
7% (normal, 0.
62% to 1.
3%; glaucoma, 0.
64% to 2.
3%).
Respective COVs under reproducibility conditions ranged from 0.
89% to 1.
9% (normal, 0.
77% to 2.
8%; glaucoma, 1.
1% to 2.
6%).
COVs of global and sectorial RNFLT measurements under repeatability conditions ranged from 0.
5% to 2.
8%.
Respective COVs under reproducibility conditions ranged from 1.
6% to 3.
5%.
Conclusions: For R&R, the COVs of measured parameters were by trend higher for glaucoma eyes compared with normal controls.
The BMO-MRW measurement system has an excellent precision taking into account that major and minor corrections of segmentation have to be done by the examiner before evaluation.

Related Results

Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Assessment of Effects of Pan-Retinal Photocoagulation on Retinal Nerve Fibre  Layer By Optical Coherence Tomography
Assessment of Effects of Pan-Retinal Photocoagulation on Retinal Nerve Fibre  Layer By Optical Coherence Tomography
Objective: To assess the Retinal Nerve Fiber Layer by Optical Coherence Tomography in patients treated with pan-retinal photocoagulation at one-month and three-month post-treatment...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Structural assessment of the optic nerve in patients with obstructive sleep apnea syndrome: Case–control study
Structural assessment of the optic nerve in patients with obstructive sleep apnea syndrome: Case–control study
Objective Obstructive sleep apnea syndrome has been identified as a possible risk factor for optic nerve pathology such as glaucoma, nonarteritic ischemic optic...
Differentiation between causes of optic disc swelling using retinal layer shape features
Differentiation between causes of optic disc swelling using retinal layer shape features
<p>The optic disc is the region of the retina where the optic nerve exits the back of the eye. A number of conditions can cause the optic disc to swell. Papilledema, optic di...

Back to Top