Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Predictive Factors for Visual Field Conversion: Comparison of Scanning Laser Polarimetry and Optical Coherence Tomography

View through CrossRef
Purpose: The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma. Methods: All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography. Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT). Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT. Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions. Contingency tables and Venn-diagrams were calculated to compare the predictive ability. Results: The study included 207 patients—75 with ocular hypertension, 85 with early glaucoma, and 47 controls. Median follow-up was 4.5 years. A total of 29 patients (14.0%) developed visual field conversion during follow-up. SLP temporal-inferior RNFL [0.667; 95% confidence interval (CI), 0.281-0.935] and SD-OCT temporal-inferior RNFL (0.571; 95% CI, 0.317-0.802) achieved the highest PPV; nerve fiber indicator (0.923; 95% CI, 0.876-0.957) and SD-OCT mean (0.898; 95% CI, 0.847-0.937) achieved the highest NPV of all investigated parameters. The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.001). Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.219) or NPV (P=0.678). Conclusions: Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC. In addition, the likelihood ratios suggest that GDx-VCC’s nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion. (http://www.ClinicalTrials.gov number, NTC00494923; Erlangen Glaucoma Registry).
Title: Predictive Factors for Visual Field Conversion: Comparison of Scanning Laser Polarimetry and Optical Coherence Tomography
Description:
Purpose: The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma.
Methods: All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography.
Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT).
Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT.
Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions.
Contingency tables and Venn-diagrams were calculated to compare the predictive ability.
Results: The study included 207 patients—75 with ocular hypertension, 85 with early glaucoma, and 47 controls.
Median follow-up was 4.
5 years.
A total of 29 patients (14.
0%) developed visual field conversion during follow-up.
SLP temporal-inferior RNFL [0.
667; 95% confidence interval (CI), 0.
281-0.
935] and SD-OCT temporal-inferior RNFL (0.
571; 95% CI, 0.
317-0.
802) achieved the highest PPV; nerve fiber indicator (0.
923; 95% CI, 0.
876-0.
957) and SD-OCT mean (0.
898; 95% CI, 0.
847-0.
937) achieved the highest NPV of all investigated parameters.
The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.
001).
Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.
219) or NPV (P=0.
678).
Conclusions: Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC.
In addition, the likelihood ratios suggest that GDx-VCC’s nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion.
(http://www.
ClinicalTrials.
gov number, NTC00494923; Erlangen Glaucoma Registry).

Related Results

Optical far‐field super‐resolution microscopy with local probes
Optical far‐field super‐resolution microscopy with local probes
The local fields, such as magnetic, optic and temperature, can be used to characterize the properties of physical and biological materials. These local fields could be measured wit...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
OPTICAL COHERENCE TOMOGRAPHY-ANGIOGRAPHY, A NEW DIAGNOSTIC AND FOLLOW-UP TOOL FOR GLAUCOMA
OPTICAL COHERENCE TOMOGRAPHY-ANGIOGRAPHY, A NEW DIAGNOSTIC AND FOLLOW-UP TOOL FOR GLAUCOMA
Glaucoma is an optic neuropathy and is one of the leading causes of irreversible blindness worldwide. There are studies on the role of vascular dysfunction in the pathogenesis of g...
Continuous wave frequency modulated optical feedback (CWFM-OF) : theory and applications
Continuous wave frequency modulated optical feedback (CWFM-OF) : theory and applications
Diese Arbeit soll einen Beitrag leisten zur Entwicklung neuer Sensorstrategien, basierend auf Phänomenen der optischer Rückkopplung, in Kombination mit die Intensitätsmodulation de...
Optimized linear wavenumber spectrometer based spectral-domain optical coherence tomography system
Optimized linear wavenumber spectrometer based spectral-domain optical coherence tomography system
In spectraldomain optical coherence tomography the sample is illuminated by a broadband light source, and the spectrum of the interference light between the light returned from the...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...

Back to Top