Test and analysis of energy characteristics of large vertical submersible pumps

View through CrossRef
The efficiency of the pump device is an important parameter to judge the overall dynamic performance of the pumping station. The commonly used method at home and abroad is to carry out model tests of the pump device. The performance parameters of the prototype pump and pump device are obtained by the similarity conversion formula. However, at present, there are not many device model tests for large vertical submersible pumps. Taking a large vertical submersible mixed-flow pumping station in China as an example, research predicted the performance of the pump device through a model test and a submersible pump prototype test. The results show that the model test of the large vertical submersible mixed-flow pump device has a maximum efficiency of approximately 77.8%, and the prototype test conversion device has a maximum efficiency of approximately 80.33%. The device model test and the pump factory prototype test results are compared. It is found that the performance parameters of the pump measured by the prototype test are in good agreement with the device model test under the design conditions, and there is a certain error when the deviation from the design conditions is significant. The device model test and the factory test of the pump are indispensable in the large-scale road of submersible pumps, and a large number of tests are needed to sum up the experience.
Title: Test and analysis of energy characteristics of large vertical submersible pumps
Description:
The efficiency of the pump device is an important parameter to judge the overall dynamic performance of the pumping station.
The commonly used method at home and abroad is to carry out model tests of the pump device.
The performance parameters of the prototype pump and pump device are obtained by the similarity conversion formula.
However, at present, there are not many device model tests for large vertical submersible pumps.
Taking a large vertical submersible mixed-flow pumping station in China as an example, research predicted the performance of the pump device through a model test and a submersible pump prototype test.
The results show that the model test of the large vertical submersible mixed-flow pump device has a maximum efficiency of approximately 77.
8%, and the prototype test conversion device has a maximum efficiency of approximately 80.
33%.
The device model test and the pump factory prototype test results are compared.
It is found that the performance parameters of the pump measured by the prototype test are in good agreement with the device model test under the design conditions, and there is a certain error when the deviation from the design conditions is significant.
The device model test and the factory test of the pump are indispensable in the large-scale road of submersible pumps, and a large number of tests are needed to sum up the experience.

Related Results

Review of Numerical Simulation Research on Submersible Mixer for Sewage
Review of Numerical Simulation Research on Submersible Mixer for Sewage
Submersible mixer is the core machinery of sewage treatment, which has a profound effect on the efficiency and performance of the submersible mixing system of sewage treatment. Thi...
Marine Operations For Platform Maintenance And Repair
Marine Operations For Platform Maintenance And Repair
Abstract This paper is concerned with the history of the development of submarine and diving support vessels in the North Sea and an analysis of future trends bas...
Investigation and Application of Reciprocating Direct-Drive Electric Submersible Plunger Pump Lifting Technology
Investigation and Application of Reciprocating Direct-Drive Electric Submersible Plunger Pump Lifting Technology
Abstract Aiming at the poor applicability, high unproductive energy consumption and the serious wear of the sucker and tube during the application of oil pumping uni...
Emerging Issues due to Adoption of Submersible Pump Technology in Marginal Quality Areas of Haryana
Emerging Issues due to Adoption of Submersible Pump Technology in Marginal Quality Areas of Haryana
Declining water table, indicative of overall negative ground water balance, has emerged as the most serious challenge to sustainability of irrigated agriculture in many states of I...
CONVERSION OF CHARACTERISTICS OF CENTRIFUGAL PUMPS TO VISCOUS LIQUIDS
CONVERSION OF CHARACTERISTICS OF CENTRIFUGAL PUMPS TO VISCOUS LIQUIDS
The urgency of the work is due to the large use of modern industry centrifugal pumps for pumping viscous liquids. In the energy sector, this is the use of fuel oil and thermal powe...
Provocative Tests in Diagnosis of Thoracic Outlet Syndrome: A Narrative Review
Provocative Tests in Diagnosis of Thoracic Outlet Syndrome: A Narrative Review
Abstract Thoracic outlet syndrome (TOS) is a group of conditions caused by the compression of the neurovascular bundle within the thoracic outlet. It is classified into three main ...
Analysis of Motions of Semi-Submersible in Sea Waves
Analysis of Motions of Semi-Submersible in Sea Waves
ABSTRACT Starting from the analysis of the forces acting on a three dimensional cylinder with arbitrary symmetrical cross-section, taking account viscous effect a...