Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Novel Simulation Model for Resident Education in Mechanical Cervical Ripening

View through CrossRef
Introduction This study aims to evaluate resident satisfaction with a novel simulation model for learning transcervical balloon catheter placement for mechanical cervical ripening.Study Design A descriptive pretest and post-test survey study of Obstetrics and Gynecology (OBGYN) residents was conducted at a single academic medical center using a low-cost model.Results Of 28 residents, 14 (50%) were recruited. 100% of participants completed the pretest and post-test survey. Residents agreed that both learning and achieving correct placement of a transcervical balloon catheter are difficult. Pretest and post-test comparisons were statistically different with respect to comfort (2.8 ± 1.5 vs. 4.0 ± 1.0, p = 0.03) and ease of learning (3.1 ± 0.8 vs. 4.1 ± 0.6, p ≤ 0.001).Discussion We present a novel simulation model that can be used by OBGYN residents in training for learning transcervical balloon catheter placement for mechanical cervical ripening.Key Points
Title: A Novel Simulation Model for Resident Education in Mechanical Cervical Ripening
Description:
Introduction This study aims to evaluate resident satisfaction with a novel simulation model for learning transcervical balloon catheter placement for mechanical cervical ripening.
Study Design A descriptive pretest and post-test survey study of Obstetrics and Gynecology (OBGYN) residents was conducted at a single academic medical center using a low-cost model.
Results Of 28 residents, 14 (50%) were recruited.
100% of participants completed the pretest and post-test survey.
Residents agreed that both learning and achieving correct placement of a transcervical balloon catheter are difficult.
Pretest and post-test comparisons were statistically different with respect to comfort (2.
8 ± 1.
5 vs.
4.
0 ± 1.
0, p = 0.
03) and ease of learning (3.
1 ± 0.
8 vs.
4.
1 ± 0.
6, p ≤ 0.
001).
Discussion We present a novel simulation model that can be used by OBGYN residents in training for learning transcervical balloon catheter placement for mechanical cervical ripening.
Key Points.

Related Results

Cervical cancer screening utilization and predictors among eligible women in Ethiopia: A systematic review and meta-analysis
Cervical cancer screening utilization and predictors among eligible women in Ethiopia: A systematic review and meta-analysis
BackgroundDespite a remarkable progress in the reduction of global rate of maternal mortality, cervical cancer has been identified as the leading cause of maternal morbidity and mo...
Cervical Cancer or Cervical Endometriosis – Review and Case Report
Cervical Cancer or Cervical Endometriosis – Review and Case Report
According to cancer death rates for women worldwide, this form of cancer ranks fourth after breast, bronchopulmonary, and colorectal cancer, affecting around 570,000 women annually...
The Women Who Fear the Unknown: Potential Drivers of the Cervical Cancer Epidemic in Rural Nigeria
The Women Who Fear the Unknown: Potential Drivers of the Cervical Cancer Epidemic in Rural Nigeria
Background: Visual inspection of the cervix under acetic acid is the most cost-effective method for the control of cervical cancer in sub-Saharan Africa. The region bears about 90%...
An Overview of Ripening Processes
An Overview of Ripening Processes
The chapter aims to address an overview of the new discoveries regarding the methods of ripening processes. The chapter presents the latest methods used in fruit and vegetable ripe...
Efficacy of cervical pessary versus cervical cerclage in preventing spontaneous preterm birth: a meta-analysis
Efficacy of cervical pessary versus cervical cerclage in preventing spontaneous preterm birth: a meta-analysis
Backgroud: The clinical efficacy and safety of cervical pessary versus cervical cerclage in preventing spontaneous preterm birth remain uncertain. Objectives: To systematically rev...
Prevention of Cervical Stenosis After Cervical Conization Using a Nelaton Catheter: A Retrospective Analysis of 556 Cases
Prevention of Cervical Stenosis After Cervical Conization Using a Nelaton Catheter: A Retrospective Analysis of 556 Cases
Objective: This study aimed to investigate 1) the incidence of and risk factors for cervical stenosis, and 2) the ability of prophylactic catheter insertion to prevent the cervical...

Back to Top