Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of the frictional resistance between different bracket types, archwires and ligation materials: An in-vitro study

View through CrossRef
In orthodontic treatment, brackets need to slide along the archwire to allow for alignment of the teeth. The lesser the friction between the bracket and the archwire, the easier it is to align the teeth and the lighter the forces required to make such movements. In recent years, patients’ esthetic demands have driven the field of orthodontics to find alternatives to conventional stainless steel bracket systems. While ceramic brackets meet the esthetic demands, their inferior frictional characteristics have always been an issue for orthodontists.The present in-vitro research study evaluates and compares the frictional resistance between various types of brackets, archwire materials and ligation methods. The purpose of the study was to equate the frictional resistance among 12 different groups using the universal testing machine, so as to recognize the factors involved in the in-vitro appraisal of resistance to sliding (RS) and inferring their clinical implications. In this study, 120 pre-adjusted edgewise upper central incisor brackets with MBT 0.022″ slot were used, which included 40 standard metal brackets, 40 ceramic brackets, 20 self-ligating metal brackets and 20 self-ligating ceramic brackets. 0.019″ x 0.025″ SS (stainless steel) archwires, esthetic archwires, Teflon-coated ligatures and conventional elastic modules to ligate the archwire to the brackets except in self-ligating brackets, were used. The average frictional resistance of Group A10 was the minimum succeeded by A9, A12, A4, A11, A8, A3, A7, A2, A6, A1 and A5. In the comparison of the mean frictional resistance of 12 different groups, the ANOVA test showed noticeably different frictional resistance amongst the groups (F=745.80, P< 0.001). Self-ligating metal bracket combinations with different archwires showed a significantly smaller magnitude of friction than self-ligating ceramic, metal and ceramic bracket combinations. Teflon-coated ligature combinations possess less friction in comparison with conventional elastomeric module combinations.
Title: Evaluation of the frictional resistance between different bracket types, archwires and ligation materials: An in-vitro study
Description:
In orthodontic treatment, brackets need to slide along the archwire to allow for alignment of the teeth.
The lesser the friction between the bracket and the archwire, the easier it is to align the teeth and the lighter the forces required to make such movements.
In recent years, patients’ esthetic demands have driven the field of orthodontics to find alternatives to conventional stainless steel bracket systems.
While ceramic brackets meet the esthetic demands, their inferior frictional characteristics have always been an issue for orthodontists.
The present in-vitro research study evaluates and compares the frictional resistance between various types of brackets, archwire materials and ligation methods.
The purpose of the study was to equate the frictional resistance among 12 different groups using the universal testing machine, so as to recognize the factors involved in the in-vitro appraisal of resistance to sliding (RS) and inferring their clinical implications.
In this study, 120 pre-adjusted edgewise upper central incisor brackets with MBT 0.
022″ slot were used, which included 40 standard metal brackets, 40 ceramic brackets, 20 self-ligating metal brackets and 20 self-ligating ceramic brackets.
0.
019″ x 0.
025″ SS (stainless steel) archwires, esthetic archwires, Teflon-coated ligatures and conventional elastic modules to ligate the archwire to the brackets except in self-ligating brackets, were used.
The average frictional resistance of Group A10 was the minimum succeeded by A9, A12, A4, A11, A8, A3, A7, A2, A6, A1 and A5.
In the comparison of the mean frictional resistance of 12 different groups, the ANOVA test showed noticeably different frictional resistance amongst the groups (F=745.
80, P< 0.
001).
Self-ligating metal bracket combinations with different archwires showed a significantly smaller magnitude of friction than self-ligating ceramic, metal and ceramic bracket combinations.
Teflon-coated ligature combinations possess less friction in comparison with conventional elastomeric module combinations.

Related Results

Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Understanding the Effects of Sterilisation Methods on Orthodontic Archwires Properties: A Review
Understanding the Effects of Sterilisation Methods on Orthodontic Archwires Properties: A Review
Sterilisation is the removal of all microorganisms, vegetative or spore-forming, from an article, surface or medium that can be accomplished through steam autoclaving, dry heat and...
Variation in form of mandibular, light, round, preformed NiTi archwires
Variation in form of mandibular, light, round, preformed NiTi archwires
ABSTRACT Objective:  To evaluate the variation in form of nickel-titanium (NiTi) archwires by comparing them with the dental arch form of normal Japane...
Clinicians' Choices in Selecting Orthodontic Archwires
Clinicians' Choices in Selecting Orthodontic Archwires
Abstract Objective: The aim of this study was to assess the choices made by clinicians in selecting archwires during the initial, intermediate and final stages of orthodontic treat...
Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires
Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires
Sterilisation removes microorganisms in the vegetative or spore states from a material, surface or medium. Ensuring infection control is of utmost importance for health safety. Pat...
TREATMENTS OF CLASS III SEVERE CROWDED TEETH WITH DAMON BRACKET SYSTEM: EXTRACTION VS NON EXTRACTION
TREATMENTS OF CLASS III SEVERE CROWDED TEETH WITH DAMON BRACKET SYSTEM: EXTRACTION VS NON EXTRACTION
One of a self-ligating bracket is Damon bracket system, most is the blending of passive self-ligating brackets and hightechnology archwires. Damon bracket system usually needs the ...
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Abstract Introduction Suture is an underreported cause for tubo-ovarian abscess (TOA) that can cause significant morbidity. This report describes a case of TOA arising from a silk ...

Back to Top