Javascript must be enabled to continue!
Optimization of storage conditions for diluted working solutions of porcine factor VIII and performance of the Bethesda assay for the determination of antiporcine FVIII inhibitor titres
View through CrossRef
Summary. The use of porcine factor VIII (FVIII) (Hyate:C, Ipsen) has proven to be very successful in treating patients with FVIII inhibitors. The best way to predict the usefulness of porcine FVIII therapy, and/or to estimate the appropriate treatment dose in a given patient, is to measure the patient inhibitor titre against porcine FVIII with the Bethesda assay, using porcine FVIII as the source of FVIII in the assay. The goals of the present study were to (1) find the optimal storage temperature, diluent and concentration for a working solution of porcine FVIII to be used as the source of FVIII for the porcine Bethesda assay, (2) assess the reliability of the labelled FVIII units in the preparation of such working solutions of porcine FVIII and (3) compare the inhibitor titres determined by the Bethesda assay using both porcine and human standard reference curves for measuring residual FVIII. The results of the present study demonstrate that a ready‐to‐use working solution of 1 U mL−1 of Hyate:C diluted in human FVIII deficient plasma, either containing or deficient in von Willebrand factor antigen, is stable for up to 12 months, at −20 °C. The preparation of the 1 U mL−1 working solution could be reliably calculated based on the units indicated on the vial label. Finally, using the human standard curve yields similar results to using the porcine standard curve for measuring any titre of allo‐ or auto‐antibody against FVIII in the Bethesda assay, using Hyate:C as the source of FVIII. These findings are of practical value when performing a porcine FVIII‐based Bethesda assay.
Title: Optimization of storage conditions for diluted working solutions of porcine factor VIII and performance of the Bethesda assay for the determination of antiporcine FVIII inhibitor titres
Description:
Summary.
The use of porcine factor VIII (FVIII) (Hyate:C, Ipsen) has proven to be very successful in treating patients with FVIII inhibitors.
The best way to predict the usefulness of porcine FVIII therapy, and/or to estimate the appropriate treatment dose in a given patient, is to measure the patient inhibitor titre against porcine FVIII with the Bethesda assay, using porcine FVIII as the source of FVIII in the assay.
The goals of the present study were to (1) find the optimal storage temperature, diluent and concentration for a working solution of porcine FVIII to be used as the source of FVIII for the porcine Bethesda assay, (2) assess the reliability of the labelled FVIII units in the preparation of such working solutions of porcine FVIII and (3) compare the inhibitor titres determined by the Bethesda assay using both porcine and human standard reference curves for measuring residual FVIII.
The results of the present study demonstrate that a ready‐to‐use working solution of 1 U mL−1 of Hyate:C diluted in human FVIII deficient plasma, either containing or deficient in von Willebrand factor antigen, is stable for up to 12 months, at −20 °C.
The preparation of the 1 U mL−1 working solution could be reliably calculated based on the units indicated on the vial label.
Finally, using the human standard curve yields similar results to using the porcine standard curve for measuring any titre of allo‐ or auto‐antibody against FVIII in the Bethesda assay, using Hyate:C as the source of FVIII.
These findings are of practical value when performing a porcine FVIII‐based Bethesda assay.
Related Results
Factor VIII/IX inhibitor testing practices in the United Kingdom: Results of a UKHCDO and UKNEQAS national survey
Factor VIII/IX inhibitor testing practices in the United Kingdom: Results of a UKHCDO and UKNEQAS national survey
AbstractIntroductionInhibitor formation is the greatest challenge facing persons with haemophilia treated with factor concentrates. The gold standard testing methodologies are the ...
P4637Elevated von Willebrand factor (VWF) and factor VIII are associated with higher clinical SYNTAX score in patients with stable coronary artery disease
P4637Elevated von Willebrand factor (VWF) and factor VIII are associated with higher clinical SYNTAX score in patients with stable coronary artery disease
Abstract
Background
Von Willebrand factor (VWF plays) central role in thrombogenesis, and circulates in a noncovalent complex wi...
Elevated Factor VIII: C Level Is a Risk Factor for Cerebral Infarction.
Elevated Factor VIII: C Level Is a Risk Factor for Cerebral Infarction.
Abstract
To explore the association between the risk of cerebral infarction (CI) and markers of coagulation and fibrinolytic systems. A prospective case-control stud...
Factor VIII Antibodies Demonstrate Type I or Type II Kinetics in Acquired Haemophilia A
Factor VIII Antibodies Demonstrate Type I or Type II Kinetics in Acquired Haemophilia A
ABSTRACTBackgroundAcquired haemophilia A (AHA) is an acquired bleeding disorder resulting from autoantibodies against Factor VIII (FVIII). Previous studies have reported difference...
Clinicopathological Features of Indeterminate Thyroid Nodules: A Single-center Cross-sectional Study
Clinicopathological Features of Indeterminate Thyroid Nodules: A Single-center Cross-sectional Study
Abstract
Introduction
Due to indeterminate cytology, Bethesda III is the most controversial category within the Bethesda System for Reporting Thyroid Cytopathology. This study exam...
An evaluation of the stability of factor VIII inhibitors in plasma and plasma dried on filter paper discs stored at room temperature
An evaluation of the stability of factor VIII inhibitors in plasma and plasma dried on filter paper discs stored at room temperature
Summary. The transportation of plasma specimens to specialized haemophilia centre laboratories for anti‐factor VIII inhibitor titre determination is often necessary. The routine me...
Demographic and Clinical Data in 118 Acquired Hemophilia a: Results from a Single Center Study
Demographic and Clinical Data in 118 Acquired Hemophilia a: Results from a Single Center Study
Introduction:
Acquired hemophilia A (AHA) is an autoimmune disorder marked by the development of autoantibodies targeting coagulation factor VIII. This rare condi...
In Vitro and Ex-Vivo Direct Effects of Coagulation Factors on on Bone Cells: Exploring the Bone Remodeling Alterations in Haemophilia A
In Vitro and Ex-Vivo Direct Effects of Coagulation Factors on on Bone Cells: Exploring the Bone Remodeling Alterations in Haemophilia A
Abstract
Haemophilia is associated with reduced bone mass and mineral density. Due to the rarity of the disease and the heterogeneity among the studies, the pathogenesis of...


