Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Finite Element Analysis of Glass Fiber-Reinforced Polymer-(GFRP) Reinforced Continuous Concrete Beams

View through CrossRef
Fiber-reinforced concrete (FRC) is a competitive solution for the durability of reinforced structures. This paper aims to observe the moment redistribution behavior occurring due to flexural and shear loading in Glass Fiber-Reinforced Polymer- (GFRP) reinforced continuous concrete beams. A rectangular cross-section was adopted in this study with dimensions of 200 mm in width and 300 mm in depth with a constant shear span-to-depth ratio of 3. The reinforcement ratio for the top and bottom were equal at sagging and hogging moment regions. A finite element model was created using Analysis System (ANSYS) and validated with the existing experimental results in the literature review. Based on the literature review, the parametric study was conducted on twelve beam specimens to evaluate the influence of concrete compressive strength, transversal GFRP stirrups ratio, and longitudinal reinforcement ratio on the redistribution of the moment in beams. Several codes and guidelines adopted different analytical models. The Canadian Standards Association (CSA) S806 adopted the modified compression field theory in predicting the shear capacity of the simply supported beams. Recently, various researchers encountered several factors and modifications to account for concrete contribution, longitudinal, and transverse reinforcement. A comparison between the predicting shear capacity of the generated finite element model, the analytical model, and the existing data from the literature was performed. The generated finite element model showed a good agreement with the experimental results, while the beam specimens failed in shear after undergoing significant moment redistribution from hogging to sagging moment region. The moment distribution observed about 21.5% from FEM of beam specimen GN-1.2-0.48-d, while the experimental results achieved 24% at failure load. For high strength concrete presented in beam specimen GH-1.2-0.63-d, the result showed about 20.2% moment distribution, compared to that achieved experimentally of 23% at failure load.
Title: Finite Element Analysis of Glass Fiber-Reinforced Polymer-(GFRP) Reinforced Continuous Concrete Beams
Description:
Fiber-reinforced concrete (FRC) is a competitive solution for the durability of reinforced structures.
This paper aims to observe the moment redistribution behavior occurring due to flexural and shear loading in Glass Fiber-Reinforced Polymer- (GFRP) reinforced continuous concrete beams.
A rectangular cross-section was adopted in this study with dimensions of 200 mm in width and 300 mm in depth with a constant shear span-to-depth ratio of 3.
The reinforcement ratio for the top and bottom were equal at sagging and hogging moment regions.
A finite element model was created using Analysis System (ANSYS) and validated with the existing experimental results in the literature review.
Based on the literature review, the parametric study was conducted on twelve beam specimens to evaluate the influence of concrete compressive strength, transversal GFRP stirrups ratio, and longitudinal reinforcement ratio on the redistribution of the moment in beams.
Several codes and guidelines adopted different analytical models.
The Canadian Standards Association (CSA) S806 adopted the modified compression field theory in predicting the shear capacity of the simply supported beams.
Recently, various researchers encountered several factors and modifications to account for concrete contribution, longitudinal, and transverse reinforcement.
A comparison between the predicting shear capacity of the generated finite element model, the analytical model, and the existing data from the literature was performed.
The generated finite element model showed a good agreement with the experimental results, while the beam specimens failed in shear after undergoing significant moment redistribution from hogging to sagging moment region.
The moment distribution observed about 21.
5% from FEM of beam specimen GN-1.
2-0.
48-d, while the experimental results achieved 24% at failure load.
For high strength concrete presented in beam specimen GH-1.
2-0.
63-d, the result showed about 20.
2% moment distribution, compared to that achieved experimentally of 23% at failure load.

Related Results

Flexural and Shear Behavior of Beams Reinforced with GFRP Rebars
Flexural and Shear Behavior of Beams Reinforced with GFRP Rebars
A new inexperienced constructing material is glass fibre reinforced polymer (GFRP) rebar. GFRP rebars are non-corrosive, non-conductive, light-weight substances and have an excessi...
The Effect of Compression Reinforcement on the Shear Behavior of Concrete Beams with Hybrid Reinforcement
The Effect of Compression Reinforcement on the Shear Behavior of Concrete Beams with Hybrid Reinforcement
Abstract This study examines the impact of steel compression reinforcement on the shear behavior of concrete beams reinforced with glass fiber reinforced polymer (GFRP) bar...
Bending and Bonding Properties of Sandwiched Polymer Concrete Composites
Bending and Bonding Properties of Sandwiched Polymer Concrete Composites
It is foreseen that the properties of Polymer Concrete (PC) can be further enhanced if the PC is bonded to or sandwiched between Glass Fibre Reinforced Plastic (GFRP) laminates, la...
Experimental and Numerical Investigation of Flexural Behaviour of GFRP Reinforced Concrete Beams using ANSYS
Experimental and Numerical Investigation of Flexural Behaviour of GFRP Reinforced Concrete Beams using ANSYS
Abstract The construction industry has made extensive use of glass fiber-reinforced polymer (GFRP) rebars to improve structural strength and stop corrosion. High tensile st...
Effects of glass fiber reinforced polymer pipe waste powder usage on concrete properties
Effects of glass fiber reinforced polymer pipe waste powder usage on concrete properties
In this study, the recycling of pipe waste powder in concrete has been experimentally investigated to reduce its harm to the environment and human health. Glass fiber reinforced po...
Experimental study on flexural behavior of GFRP reinforced concrete beams
Experimental study on flexural behavior of GFRP reinforced concrete beams
Glass fiber reinforced polymer (GFRP) has been investigated and popularly used as internal reinforcement in the construction field worldwide. Although GFRP is not easy to be corrod...
Experimental studies into the strength of compressed concrete elements reinforced with fiber-reinforced polymer rebars
Experimental studies into the strength of compressed concrete elements reinforced with fiber-reinforced polymer rebars
Introduction. Reinforced concrete structures affected by various aggressive environments operate under off-center compression. Fiber-reinforced polymer (FRP) rebars replacing steel...
Analisis Kuat Lentur Balok Beton Bertulang dengan Perkuatan Glass Fiber Reinforced Polymer (GFRP) Menggunakan Program Abaqus
Analisis Kuat Lentur Balok Beton Bertulang dengan Perkuatan Glass Fiber Reinforced Polymer (GFRP) Menggunakan Program Abaqus
Strengthening is needed to restore structural capacity such as installing GFRP. This research aims to analyze the flexural strength of reinforced concrete beams using the Abaqus 20...

Back to Top