Javascript must be enabled to continue!
Comparison of perioperative parameters in one-handed rotational phacoemulsification versus conventional phacoemulsification and femtosecond laser-assisted cataract surgery
View through CrossRef
AIM: To compare perioperative parameters of one-handed rotational phacoemulsification technique (one-handed phaco-roll) with each of other two techniques, “Divide et Conquer” and femtosecond laser-assisted cataract surgery (FLACS)
METHODS: In this retrospective and comparative cohort study, eyes with uncomplicated cataract (nuclear density grade 2 to 3) treated routinely with one-handed phaco-roll (n=23; Group 1) or “Divide et Conquer” (n=23; Group 2) or FLACS (n=23; Group 3) were enrolled. Intraoperative parameters including effective phaco-time (EPt), ultrasound time (USt), aspiration time, surgical time, phacoemulsification (phaco)-power, balanced salt solution (BSS) use, cumulative dissipated energy (CDE) were recorded and compared. Clinical outcomes including best corrected visual acuity (BCVA), corneal endothelial cell density (ECD), endothelial cell loss (ECL), central corneal thickness (CCT) and central macular thickness (CMT), were assessed and compared pre-operatively and at 1mo after surgery.
RESULTS: Aspiration and surgical time, and BSS used were lower in Group 1 (P<0.01) than other groups. EPt, phaco-power and CDE were lower in Group 1 (P<0.05) than Group 2 but not significantly different from Group 3. In Group 1, USt was lower (P<0.05) than Group 2 but higher (P<0.05) than Group 3. BCVA improved in all groups without significant difference between Group 1 and the other ones. No significant differences regarding all post-operative morphologic outcomes (ECD, ECL, CCT, CMT) were reported. No clinical complications occurred.
CONCLUSION: One-handed phaco-roll seems to be less time-consuming than “Divide et Conquer” and FLACS and less energy-consuming than “Divide et Conquer”. Furthermore, one-handed phaco-roll seems to have an equal safety profile compared to the other two techniques.
Press of International Journal of Ophthalmology (IJO Press)
Title: Comparison of perioperative parameters in one-handed rotational phacoemulsification versus conventional phacoemulsification and femtosecond laser-assisted cataract surgery
Description:
AIM: To compare perioperative parameters of one-handed rotational phacoemulsification technique (one-handed phaco-roll) with each of other two techniques, “Divide et Conquer” and femtosecond laser-assisted cataract surgery (FLACS)
METHODS: In this retrospective and comparative cohort study, eyes with uncomplicated cataract (nuclear density grade 2 to 3) treated routinely with one-handed phaco-roll (n=23; Group 1) or “Divide et Conquer” (n=23; Group 2) or FLACS (n=23; Group 3) were enrolled.
Intraoperative parameters including effective phaco-time (EPt), ultrasound time (USt), aspiration time, surgical time, phacoemulsification (phaco)-power, balanced salt solution (BSS) use, cumulative dissipated energy (CDE) were recorded and compared.
Clinical outcomes including best corrected visual acuity (BCVA), corneal endothelial cell density (ECD), endothelial cell loss (ECL), central corneal thickness (CCT) and central macular thickness (CMT), were assessed and compared pre-operatively and at 1mo after surgery.
RESULTS: Aspiration and surgical time, and BSS used were lower in Group 1 (P<0.
01) than other groups.
EPt, phaco-power and CDE were lower in Group 1 (P<0.
05) than Group 2 but not significantly different from Group 3.
In Group 1, USt was lower (P<0.
05) than Group 2 but higher (P<0.
05) than Group 3.
BCVA improved in all groups without significant difference between Group 1 and the other ones.
No significant differences regarding all post-operative morphologic outcomes (ECD, ECL, CCT, CMT) were reported.
No clinical complications occurred.
CONCLUSION: One-handed phaco-roll seems to be less time-consuming than “Divide et Conquer” and FLACS and less energy-consuming than “Divide et Conquer”.
Furthermore, one-handed phaco-roll seems to have an equal safety profile compared to the other two techniques.
Related Results
Changes in Aqueous Humor pH After Femtosecond Laser-Assisted Cataract Surgery
Changes in Aqueous Humor pH After Femtosecond Laser-Assisted Cataract Surgery
PURPOSE:
To compare aqueous humor pH values in patients during femtosecond laser-assisted cataract surgery with patients during conventional phacoemulsification.
...
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
PurposeThis study aimed to revise data published in the literature on the effects of cataract surgery on tear film characteristics, in relation to personal clinical surgical experi...
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Background: Phacoemulsification (phaco) of mature intumescent cataract is one of the most difficult to perform anterior eye surgeries. In mature intumescent cataract phaco, the mos...
“Prevalence And Determinants Of Age-Related Cataract In The Rural Population: A Cross-Sectional Study”
“Prevalence And Determinants Of Age-Related Cataract In The Rural Population: A Cross-Sectional Study”
Background of the Study: Age-related cataract is the leading cause of preventable blindness and visual impairment worldwide, particularly among elderly populations in low- and midd...
Relationship Between Cataract Surgery and Mortality in Elderly Patients with Cataract: Nationwide Population-based Cohort Study in South Korea
Relationship Between Cataract Surgery and Mortality in Elderly Patients with Cataract: Nationwide Population-based Cohort Study in South Korea
Abstract
There were a few studies showing conflicting findings with regard to the relationship between cataract surgery and all-cause mortality. It is uncertain whether cat...
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
Background: The integrity of the clear corneal incision is fundamental to safety, wound sealing, and refractive stability in cataract surgery. Although femtosecond laser-assisted c...
Phacoemulsification in trabeculectomized eyes
Phacoemulsification in trabeculectomized eyes
Abstract.Purpose: To evaluate retrospectively risk indicators for cataract surgery and the effect of phacoemulsification on intraocular pressure (IOP) control in eyes that have u...
Femtosecond Laser-Assisted Cataract Surgery: Analysis of Surgical Phases and Comparison with Standard Phacoemulsification in Uncomplicated Cataracts
Femtosecond Laser-Assisted Cataract Surgery: Analysis of Surgical Phases and Comparison with Standard Phacoemulsification in Uncomplicated Cataracts
The aim of this work is to compare the time of surgical phases and the cumulative dissipated energy (CDE) of the phacoemulsification phase in femtosecond laser-assisted cataract su...

