Javascript must be enabled to continue!
COMPARATIVE EVALUATION OF MICROLEAKAGE AND RETENTION OF DIFFERENT LUTING AGENTS USED FOR CEMENTING CUSTOM MADE STAINLESS STEEL BANDS ON MOLARS-AN IN VITRO STUDY
View through CrossRef
Aim: The aim of this study was to evaluate the microleakage and retentive strength of various luting agents. Material And Method: Forty samples were randomly divided into group A (assessment of microleakage of different luting agents ) and B (assessment of the retentive strength of the different luting agents) with 20 samples each. Both Group A ( assessment of microleakage of different luting agents) and B (assessment of the retentive strength of the different luting agents) were further subdivided into group A1, A2, A3 and A4 & B1, B2, B3 and B4 respectively with 5 samples each. Group A1, B1- ZINC PHOSPHATE( CONTROL GROUP )Group A2, B2 - SPEED CEM PLUS Group A3, B3 - HY BOND CX SMART GLASIONOMER Group A4, B4- NO CEMENT ( NEGATIVE GROUP) Results: Speed CEM Plus has the lowest mean value while zinc phosphate has the highest mean value of microleakage. While it was noted that Speed CEM Plus had the highest mean value while zinc phosphate has the lowest mean value of retentive strength Conclusion: Speed CEM Plus can be recommended as a potential and efficiency luting cement material in term of lower microleakage and high retentive strength for cementing stainless steel band on molar.
International Journal Of Advanced Research
Title: COMPARATIVE EVALUATION OF MICROLEAKAGE AND RETENTION OF DIFFERENT LUTING AGENTS USED FOR CEMENTING CUSTOM MADE STAINLESS STEEL BANDS ON MOLARS-AN IN VITRO STUDY
Description:
Aim: The aim of this study was to evaluate the microleakage and retentive strength of various luting agents.
Material And Method: Forty samples were randomly divided into group A (assessment of microleakage of different luting agents ) and B (assessment of the retentive strength of the different luting agents) with 20 samples each.
Both Group A ( assessment of microleakage of different luting agents) and B (assessment of the retentive strength of the different luting agents) were further subdivided into group A1, A2, A3 and A4 & B1, B2, B3 and B4 respectively with 5 samples each.
Group A1, B1- ZINC PHOSPHATE( CONTROL GROUP )Group A2, B2 - SPEED CEM PLUS Group A3, B3 - HY BOND CX SMART GLASIONOMER Group A4, B4- NO CEMENT ( NEGATIVE GROUP) Results: Speed CEM Plus has the lowest mean value while zinc phosphate has the highest mean value of microleakage.
While it was noted that Speed CEM Plus had the highest mean value while zinc phosphate has the lowest mean value of retentive strength Conclusion: Speed CEM Plus can be recommended as a potential and efficiency luting cement material in term of lower microleakage and high retentive strength for cementing stainless steel band on molar.
Related Results
Microleakage of luting cements in CAD/CAM pediatric zirconia crowns: An in vitro study
Microleakage of luting cements in CAD/CAM pediatric zirconia crowns: An in vitro study
Abstract
Objectives To assess and compare the microleakage of custom-made zirconia crowns (CZCs) and prefabricated zirconia crowns (PZCs) on primary maxillary incisors when...
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
L'acer inoxidable està essent utilitzat de manera creixent en els últims anys als sectors de la indústria i de l'arquitectura gràcies a la seva resistència a la corrosió, facilitat...
Microorganisms for Secondary Cementation: A Promising Solution for Cracks and Microchannels in Oil Well Bore Casings
Microorganisms for Secondary Cementation: A Promising Solution for Cracks and Microchannels in Oil Well Bore Casings
Abstract
Secondary cementing plays a crucial role in oil and gas well operations by providing zonal isolation and ensuring the integrity of wellbore structures. Seco...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Comparison of Microleakage of Pedo Jacket Crowns and Stainless Steel Crowns Cemented with Different Cements
Comparison of Microleakage of Pedo Jacket Crowns and Stainless Steel Crowns Cemented with Different Cements
Objectives: This study aimed to assess the microleakage of Pedo Jacket crowns compared to stainless steel crowns (SSCs) cemented with different luting cements.
Materials and Metho...
A Microleakage Study of Various Dental Fillers (Nanohydroxyapatite, Bioactive Glass and Nanohydroxyapatite/Bioactive Glass) for Dental Restoration
A Microleakage Study of Various Dental Fillers (Nanohydroxyapatite, Bioactive Glass and Nanohydroxyapatite/Bioactive Glass) for Dental Restoration
Microleakage has been considered a common issue in dental restorations, leading to secondary or recurrent caries. One approach to addressing microleakage in dental cements focuses ...
Bond Strength of Overdenture Locator Posts Cemented with Seven Luting Agents
Bond Strength of Overdenture Locator Posts Cemented with Seven Luting Agents
ABSTRACT
Statement of the problem
Post retention is crucial factor in restoration survival. Posts are commonly failed due to loss of retention. It is unknown which luting agents w...
Evaluation of the Influence of Three different Temperatures on Microleakage of Two Self-etch and One Total-etch Adhesives
Evaluation of the Influence of Three different Temperatures on Microleakage of Two Self-etch and One Total-etch Adhesives
ABSTRACT
Aim
To evaluate the bonding temperature effect on dentinrestoration microleakage.
The null hypothesis of the study is that the score of microleakage is identical among di...

