Enhancement of Draft in Crude Charge Heater

View through CrossRef
Abstract Objectives/Scope Draft limitation in natural-draft heaters can restrict firing duty, combustion-air availability, flame stability, and unit throughput specially upon increasing beyond design firing duty. This paper presents an online field implementation in a 45-year-old natural-draft crude charge heater in which directed medium-pressure steam was introduced downstream of the convection section and upstream of the stack to increase available draft without stack-height modification or heater shutdown. Methods, Procedures, Process A steam lance arrangement was installed through two existing flue gas monitoring ports in the stack take-off area while the heater remained in service and without shell metal cutting. The lance design used staggered ports of ~8 mm diameter, after iterative checks on inlet velocity, structural integrity, cantilever loading, and entrainment performance. For matched-load and higher-load operation: radiation-top draft improvement of at least 3-4 mm WC at 15 kg/cm2g MP steam, visible flame-length reduction of at least 10% of radiant-section height, at least 2% unit-load increase, negative radiation-top draft at higher load, and at least 1.0 vol.% oxygen increase. Results, Observations, Conclusions Success criteria for matched unit load, radiation-top draft improved by approximately 3-4 mm WC. During higher-load operation, the unit capacity increased by 5% while maintaining stable heater operation and negative radiation-top draft, with a measured value of approximately -2.5 mm WC. Burner-level draft improved to approximately -9.0 to -10.0 mm WC. The visible flame length reduced by at least 10% at matched load, and field observations indicated shorter, narrower, and more uniform flame patterns. Excess oxygen increased by approximately 1.0-1.5 vol.% at stack level and 0.5-1.5 vol.% at the radiation-cell top. Thermal efficiency reduced by approximately 3-4%, with associated increases in bridgewall temperature, stack temperature, specific fuel consumption, and superheated LP steam outlet temperature. The superheating steam coil was adequate for continued operation after rerating. The implementation was recommended to remain in service with continued monitoring, steam-lance parameter tracking, inspection during turnaround, additional support for steam lance and downstream steam-line rerating. Novel/Additive Information The work demonstrates a practical online draft-debottlenecking method for a natural-draft charge heater where conventional stack modification was less attractive because of aged structural and implementation complexity.
Title: Enhancement of Draft in Crude Charge Heater
Description:
Abstract Objectives/Scope Draft limitation in natural-draft heaters can restrict firing duty, combustion-air availability, flame stability, and unit throughput specially upon increasing beyond design firing duty.
This paper presents an online field implementation in a 45-year-old natural-draft crude charge heater in which directed medium-pressure steam was introduced downstream of the convection section and upstream of the stack to increase available draft without stack-height modification or heater shutdown.
Methods, Procedures, Process A steam lance arrangement was installed through two existing flue gas monitoring ports in the stack take-off area while the heater remained in service and without shell metal cutting.
The lance design used staggered ports of ~8 mm diameter, after iterative checks on inlet velocity, structural integrity, cantilever loading, and entrainment performance.
For matched-load and higher-load operation: radiation-top draft improvement of at least 3-4 mm WC at 15 kg/cm2g MP steam, visible flame-length reduction of at least 10% of radiant-section height, at least 2% unit-load increase, negative radiation-top draft at higher load, and at least 1.
0 vol.
% oxygen increase.
Results, Observations, Conclusions Success criteria for matched unit load, radiation-top draft improved by approximately 3-4 mm WC.
During higher-load operation, the unit capacity increased by 5% while maintaining stable heater operation and negative radiation-top draft, with a measured value of approximately -2.
5 mm WC.
Burner-level draft improved to approximately -9.
0 to -10.
0 mm WC.
The visible flame length reduced by at least 10% at matched load, and field observations indicated shorter, narrower, and more uniform flame patterns.
Excess oxygen increased by approximately 1.
0-1.
5 vol.
% at stack level and 0.
5-1.
5 vol.
% at the radiation-cell top.
Thermal efficiency reduced by approximately 3-4%, with associated increases in bridgewall temperature, stack temperature, specific fuel consumption, and superheated LP steam outlet temperature.
The superheating steam coil was adequate for continued operation after rerating.
The implementation was recommended to remain in service with continued monitoring, steam-lance parameter tracking, inspection during turnaround, additional support for steam lance and downstream steam-line rerating.
Novel/Additive Information The work demonstrates a practical online draft-debottlenecking method for a natural-draft charge heater where conventional stack modification was less attractive because of aged structural and implementation complexity.

Related Results

[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED]Gro-X Male Enhancement Reviews - Is It Worth the Money? Scam or Legit? Gro-X Male Enhancement Male health is very important, especially for a couple. Low sperm count an...
Crude Oil Characterization For Micellar Enhanced Oil Recovery
Crude Oil Characterization For Micellar Enhanced Oil Recovery
Abstract Chemically enhanced oil recovery depends on the phase and interfacial properties of the crude phase and interfacial properties of the crude Oil-brine-sur...
Efficient And Safe Operation of Indirect Fired Heaters
Efficient And Safe Operation of Indirect Fired Heaters
Abstract Indirect fired heaters are used to preheat natural gas pipeline flow upstream of gas pressure regulating equipment to lessen the possibility of water ice...
[RETRACTED] Omni Male Enhancement Review v1
[RETRACTED] Omni Male Enhancement Review v1
[RETRACTED][video width="852" height="480" mp4="https://lexcliq.com/wp-content/uploads/2022/04/Untitled-video-‐-Made-with-Clipchamp.mp4"][/video] Omni Male Enhancement Reviews Omn...
[RETRACTED] Omni Male Enhancement Review v1
[RETRACTED] Omni Male Enhancement Review v1
[RETRACTED][video width="852" height="480" mp4="https://lexcliq.com/wp-content/uploads/2022/04/Untitled-video-‐-Made-with-Clipchamp.mp4"][/video] Omni Male Enhancement Reviews Omn...
Crude Oil and Crude Oil Derivatives Transactions by Oil and Gas Producers.
Crude Oil and Crude Oil Derivatives Transactions by Oil and Gas Producers.
This study attempts to resolve two important issues. First, it investigates the diversification benefit of crude oil for equities. Second, it examines whether or not crude oil deri...
TEMPERATURE DISTRIBUTION SIMULATION AND OPTIMIZATION DESIGN OF ELECTRIC HEATER FOR IN-SITU OIL SHALE HEATING; pp. 105–120
TEMPERATURE DISTRIBUTION SIMULATION AND OPTIMIZATION DESIGN OF ELECTRIC HEATER FOR IN-SITU OIL SHALE HEATING; pp. 105–120
Electric heating is the main method of exploiting oil shale and electric heater is the key part of the heating element. In this paper, the tem­perature distribution of the electri...

Back to Top