Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Three-dimensional finite element analysis comparative model of tooth–implant nonrigid fixation

View through CrossRef
Connecting implants with teeth is sometimes considered for the support of prostheses in partial edentulism, especially in periodontally compromised and surgical treated patients. The aim of this study is the presentation of a model of tooth–implant nonrigid fixation in comparison with implant–implant and implant–tooth rigid fixation by three-dimensional (3D) finite element analysis. As a model, a situation with a mandibular second premolar and two molars edentulism was selected. Two implantation options with three prosthetics designs were considered. The comparative analysis of stress and strain distribution values under vertical 100 and 200 N loading was performed. The highest peri-implant crestal bone stress distribution was observed in the model with the implant–tooth rigid fixation with 200 N vertical loading with results of 136.56 MPa. In the model with implant–tooth nonrigid fixation, the maximum strain value was observed in the tooth–connector zone and the stress distribution was higher in the connectors and the prosthesis pontic zone, with a maximal value of 27.77 MPa. The design of a tooth–implant fixed denture could be suggested as a method of choice for rehabilitation of the posterior edentulous segment in cases when only one distal implant could be installed. Further clinical research is required to obtain reliable validation data for the proposed method.
Title: Three-dimensional finite element analysis comparative model of tooth–implant nonrigid fixation
Description:
Connecting implants with teeth is sometimes considered for the support of prostheses in partial edentulism, especially in periodontally compromised and surgical treated patients.
The aim of this study is the presentation of a model of tooth–implant nonrigid fixation in comparison with implant–implant and implant–tooth rigid fixation by three-dimensional (3D) finite element analysis.
As a model, a situation with a mandibular second premolar and two molars edentulism was selected.
Two implantation options with three prosthetics designs were considered.
The comparative analysis of stress and strain distribution values under vertical 100 and 200 N loading was performed.
The highest peri-implant crestal bone stress distribution was observed in the model with the implant–tooth rigid fixation with 200 N vertical loading with results of 136.
56 MPa.
In the model with implant–tooth nonrigid fixation, the maximum strain value was observed in the tooth–connector zone and the stress distribution was higher in the connectors and the prosthesis pontic zone, with a maximal value of 27.
77 MPa.
The design of a tooth–implant fixed denture could be suggested as a method of choice for rehabilitation of the posterior edentulous segment in cases when only one distal implant could be installed.
Further clinical research is required to obtain reliable validation data for the proposed method.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Biomechanics of Artificial Pedicle Fixation in a 3d-printed Prosthesis After Total en Bloc Spondylectomy: A Finite Element Analysis
Biomechanics of Artificial Pedicle Fixation in a 3d-printed Prosthesis After Total en Bloc Spondylectomy: A Finite Element Analysis
Abstract Background: This study compared the biomechanics of artificial pedicle fixation in spine reconstruction with a 3-dimensional (3D)-printed prosthesis after total en...
Image Stitching Based on Nonrigid Warping for Urban Scene
Image Stitching Based on Nonrigid Warping for Urban Scene
Image stitching based on a global alignment model is widely used in computer vision. However, the resulting stitched image may look blurry or ghosted due to parallax. To solve this...
TRATAMENTO CIRÚRGICO DE CANINO INCLUSO EM REGIÃO MENTUAL: RELATO DE CASO
TRATAMENTO CIRÚRGICO DE CANINO INCLUSO EM REGIÃO MENTUAL: RELATO DE CASO
RESUMOO dente denominado incluso nada mais é que um dente retido ou impactado dentro do alvéolo dentário de maneira parcial ou completa que não conseguiu erupcionar por motivos pat...
Restoration of human tooth enamel
Restoration of human tooth enamel
AbstractHuman tooth enamel, consisting of hydroxyapatite nanocrystals (∼85–88 vol%), proteins (∼2‐3 vol%), and requisite water (∼10–12 vol%), is 1–3 mm thick at the outer layer of ...
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Abstract Background:Posterior lumbar interbody fusion(PLIF) is the most common surgical method for lumbar fusion surgery, and pedicle screws(PS)can provide effective fixati...
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
ABSTRACT Introduction Syndesmotic injuries present a challenge to orthopedic surgeons. Malreduction of the syndesmosis has been reported to cause instability and secondary osteoar...

Back to Top