Javascript must be enabled to continue!
Tropical tropospheric ozone columns from nadir retrievals of GOME-1/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A (1996–2012)
View through CrossRef
Abstract. Tropical tropospheric ozone columns are retrieved with the convective cloud differential (CCD) technique using total ozone columns and cloud parameters from different European satellite instruments. Monthly-mean tropospheric column amounts [DU] are calculated by subtracting the above-cloud ozone column from the total column. A CCD algorithm (CCD_IUP) has been developed as part of the verification algorithm developed for TROPOspheric Monitoring Instrument (TROPOMI) on Sentinel 5-precursor (S5p) mission, which was applied to GOME/ERS-2 (1995–2003), SCIAMACHY/Envisat (2002–2012), and GOME-2/MetOp-A (2007–2012) measurements. Thus a unique long-term record of monthly-mean tropical tropospheric ozone columns (20° S–20° N) from 1996 to 2012 is now available. An uncertainty estimation has been performed, resulting in a tropospheric ozone column uncertainty less than 2 DU ( < 10 %) for all instruments. The dataset has not been yet harmonised into one consistent; however, comparison between the three separate datasets (GOME/SCIAMACHY/GOME-2) shows that GOME-2 overestimates the tropical tropospheric ozone columns by about 8 DU, while SCIAMACHY and GOME are in good agreement. Validation with Southern Hemisphere ADditional OZonesondes (SHADOZ) data shows that tropospheric ozone columns from the CCD_IUP technique and collocated integrated ozonesonde profiles from the surface up to 200 hPa are in good agreement with respect to range, interannual variations, and variances. Biases within ±5 DU and root-mean-square (RMS) deviation of less than 10 DU are found for all instruments. CCD comparisons using SCIAMACHY data with tropospheric ozone columns derived from limb/nadir matching have shown that the bias and RMS deviation are within the range of the CCD_IUP comparison with the ozonesondes. The 17-year dataset can be helpful for evaluating chemistry models and performing climate change studies.
Title: Tropical tropospheric ozone columns from nadir retrievals of GOME-1/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A (1996–2012)
Description:
Abstract.
Tropical tropospheric ozone columns are retrieved with the convective cloud differential (CCD) technique using total ozone columns and cloud parameters from different European satellite instruments.
Monthly-mean tropospheric column amounts [DU] are calculated by subtracting the above-cloud ozone column from the total column.
A CCD algorithm (CCD_IUP) has been developed as part of the verification algorithm developed for TROPOspheric Monitoring Instrument (TROPOMI) on Sentinel 5-precursor (S5p) mission, which was applied to GOME/ERS-2 (1995–2003), SCIAMACHY/Envisat (2002–2012), and GOME-2/MetOp-A (2007–2012) measurements.
Thus a unique long-term record of monthly-mean tropical tropospheric ozone columns (20° S–20° N) from 1996 to 2012 is now available.
An uncertainty estimation has been performed, resulting in a tropospheric ozone column uncertainty less than 2 DU ( < 10 %) for all instruments.
The dataset has not been yet harmonised into one consistent; however, comparison between the three separate datasets (GOME/SCIAMACHY/GOME-2) shows that GOME-2 overestimates the tropical tropospheric ozone columns by about 8 DU, while SCIAMACHY and GOME are in good agreement.
Validation with Southern Hemisphere ADditional OZonesondes (SHADOZ) data shows that tropospheric ozone columns from the CCD_IUP technique and collocated integrated ozonesonde profiles from the surface up to 200 hPa are in good agreement with respect to range, interannual variations, and variances.
Biases within ±5 DU and root-mean-square (RMS) deviation of less than 10 DU are found for all instruments.
CCD comparisons using SCIAMACHY data with tropospheric ozone columns derived from limb/nadir matching have shown that the bias and RMS deviation are within the range of the CCD_IUP comparison with the ozonesondes.
The 17-year dataset can be helpful for evaluating chemistry models and performing climate change studies.
Related Results
Tropical tropospheric ozone columns from nadir retrievals of GOME-1/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A (1996-2012)
Tropical tropospheric ozone columns from nadir retrievals of GOME-1/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A (1996-2012)
Abstract. Tropical tropospheric ozone columns are retrieved with the Convective Clouds Differential (CCD) technique using total ozone columns and cloud parameters from different Eu...
The ESA GOME-Evolution “Climate” water vapor product: a homogenized time series of H
2
O columns from GOME, SCIAMACHY, and GOME-2
The ESA GOME-Evolution “Climate” water vapor product: a homogenized time series of H
2
O columns from GOME, SCIAMACHY, and GOME-2
Abstract. We present time series of the global distribution of water vapor columns over more than 2 decades based on measurements from the satellite instruments GOME, SCIAMACHY, an...
The ESA GOME-Evolution "Climate" water vapor product: A homogenized time-series of H
2
O columns from GOME/SCIAMACHY/GOME-2
The ESA GOME-Evolution "Climate" water vapor product: A homogenized time-series of H
2
O columns from GOME/SCIAMACHY/GOME-2
Abstract. We present time-series of the global distribution of water vapor columns over more than two decades based on measurements from the satellite instruments GOME, SCIAMACHY, ...
Revised temperature-dependent ozone absorption cross-section spectra (Bogumil et al.) measured with the SCIAMACHY satellite spectrometer
Revised temperature-dependent ozone absorption cross-section spectra (Bogumil et al.) measured with the SCIAMACHY satellite spectrometer
Abstract. Absorption cross-section spectra for ozone and other trace gases had been measured using the Scanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMA...
Global carbon monoxide as retrieved from SCIAMACHY by WFM-DOAS
Global carbon monoxide as retrieved from SCIAMACHY by WFM-DOAS
Abstract. Vertical columns of CO have been retrieved from SCIAMACHY/ENVISAT short wave/near infrared (~2.3µm) nadir spectra using the Weighting Function Modified (WFM) DOAS retriev...
Addressing degradation and geometry effects to develop consistent global solar induced fluorescence records from GOME-2A and GOME-2B (2007-2023)
Addressing degradation and geometry effects to develop consistent global solar induced fluorescence records from GOME-2A and GOME-2B (2007-2023)
Space-based solar-induced fluorescence (SIF) observations provide critical insights into vegetation activity over time. The GOME-2A and GOME-2B instruments offer extensive global S...
Revised temperature dependent ozone absorption cross section spectra (Bogumil et al.) measured with the sciamachy satellite spectrometer
Revised temperature dependent ozone absorption cross section spectra (Bogumil et al.) measured with the sciamachy satellite spectrometer
Abstract. Ozone absorption cross section spectra and other trace gases had been measured using the Scanning Imaging Absorption spectroMeter for Atmospheric ChartograpHY (SCIAMACHY)...
Validation of all S5P ozone products (total columns, tropospheric columns and profiles) with a single reference network. 
Validation of all S5P ozone products (total columns, tropospheric columns and profiles) with a single reference network. 
Ground-based Fourier Transform Infrared (FTIR) instruments from the Network for the Detection of Atmospheric Composition Change (NDACC) provide long-term and continuous measurement...

