Cantilever-Type Local Deformation Transducer for Local Axial Strain Measurement in Triaxial Test

View through CrossRef
Abstract The cantilever-type local deformation transducer (cantilever-LDT) was developed as an alternative local axial strain measurement device for triaxial testing. The transducer behaves as a cantilever beam and the deflection at its free-end is measured by the output from the strain gages attached near the fixed-end. By placing two cantilever-LDTs along the same vertical alignment but at different levels of a specimen, the local axial strain is obtained from the relative movements of two cantilever-LDTs. The advantages over the original-LDT proposed by Goto et al. (1991) are: (i) a linear calibration curve, (ii) capability to release itself at large strains, and (iii) larger working range. With a gage length of 50 mm, the resolution, accuracy, and working range are 0.0012 %, 0.003 %, and 6 %, respectively. The triaxial test results on heavily overconsolidated clay specimens show that the cantilever-LDT can be used satisfactorily to measure the local axial strain accurately, but the reliability depends very much on the quality of specimen preparation and setup.
Title: Cantilever-Type Local Deformation Transducer for Local Axial Strain Measurement in Triaxial Test
Description:
Abstract The cantilever-type local deformation transducer (cantilever-LDT) was developed as an alternative local axial strain measurement device for triaxial testing.
The transducer behaves as a cantilever beam and the deflection at its free-end is measured by the output from the strain gages attached near the fixed-end.
By placing two cantilever-LDTs along the same vertical alignment but at different levels of a specimen, the local axial strain is obtained from the relative movements of two cantilever-LDTs.
The advantages over the original-LDT proposed by Goto et al.
(1991) are: (i) a linear calibration curve, (ii) capability to release itself at large strains, and (iii) larger working range.
With a gage length of 50 mm, the resolution, accuracy, and working range are 0.
0012 %, 0.
003 %, and 6 %, respectively.
The triaxial test results on heavily overconsolidated clay specimens show that the cantilever-LDT can be used satisfactorily to measure the local axial strain accurately, but the reliability depends very much on the quality of specimen preparation and setup.

Related Results

On Some Issues in Triaxial Extension Tests
On Some Issues in Triaxial Extension Tests
Abstract Results of triaxial extension tests on dry sand are presented. Special attention is paid to the factors influencing the results in triaxial extension tests....
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Biosurfactants are natural substances produced by several bacterial and fungal organisms that are amphiphilic and are extracellular (a part of the cell membrane). Biosurfactants ca...
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
The dynamical motion at any point on the cantilever of an atomic force microscope can be expressed quite generally as a superposition of simple harmonic oscillators corresponding t...
Casing Deformation in Ekofisk
Casing Deformation in Ekofisk
Summary Casing deformation resulting from reservoir compaction occurred in the Ekofisk field operated by Phillips Petroleum Co. Norway and is a serious problem in...
Provocative Tests in Diagnosis of Thoracic Outlet Syndrome: A Narrative Review
Provocative Tests in Diagnosis of Thoracic Outlet Syndrome: A Narrative Review
Abstract Thoracic outlet syndrome (TOS) is a group of conditions caused by the compression of the neurovascular bundle within the thoracic outlet. It is classified into three main ...
Research on acoustic control of coupled vibration system of transducers using acoustic surface and topological defect structures
Research on acoustic control of coupled vibration system of transducers using acoustic surface and topological defect structures
<sec>How to regulate the sound waves in the coupled vibration system of complex power ultrasonic transducers and design high-performance transducer systems has always been an...
Development of large size Disk Transducer to evaluate elastic properties of coarse granular materials
Development of large size Disk Transducer to evaluate elastic properties of coarse granular materials
A new type of Disk transducer with the size of 80 mm diameter has been developed by assembling p-type piezo ceramic elements and s-type piezo ceramic elements, in order to carry ou...
SU‐E‐I‐114: Clinical Ultrasound Transducer Degradation Effects on the Accuracy of Spectral Doppler Velocity Measurements
SU‐E‐I‐114: Clinical Ultrasound Transducer Degradation Effects on the Accuracy of Spectral Doppler Velocity Measurements
Purpose: Ultrasound Doppler velocity measurements are routinely used to determine the severity of a stenosis in the carotid, renal or peripheral arteries. The objective of this stu...

Back to Top